W2415-760F-NC-BK Elpac, W2415-760F-NC-BK Datasheet

no-image

W2415-760F-NC-BK

Manufacturer Part Number
W2415-760F-NC-BK
Description
Adapter; 15 V; 24 W; 1.6; 100 to 240; 0.43 A @ 115 VAC; 47 to 63 Hz; 4.25 in.
Manufacturer
Elpac
Type
Medicalr
Datasheet

Specifications of W2415-760F-NC-BK

Brand/series
MW24 Series
Configuration
Enclosed
Current, Input
0.43 A @ 115 VAC A
Current, Leakage
55 uA @ 132 VAC Test Voltage
Current, Output
1.6 A
Frequency, Input
47 to 63 Hz Hz
Height
1.3 in.
Length
4.25 in.
Mounting Type
Desktop
Number Of Outputs
1
Operation
Switching
Output
15 VDC @ 1.6 A
Power Rating
24 W
Power, Output
24 W
Primary Type
AC-DC
Regulation, Line
±1% (Typ.)
Regulation, Load
±5% (Typ.)
Special Features
High Efficiency, Output Floating
Standards
UL⁄cUL Recognized, CE Approved, Meets FCC Class B, CISPR11 Class B
Temperature, Operating
0 to +40 °C
Voltage, Input
100 to 240 VAC
Voltage, Output
15 VDC
Width
2.5 in.
Input
100-240 VAC, 50/60 Hz
Ripple/noise
±0.5% V p-p
Operating Temperature
0-40°C
Ul60601-1, Csa
C22.2 No. 601.1-M90, IEC60601-1
A
1-888-357-2280
saleselpac@iccus.com
www.iccus.com
+44.1383.432920
saleseurope@iccus.com
TECHNICAL SUPPORT
wORLDwIDE
EUROPE
Notes
**Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
Input Voltage
Input Frequency
Input Current
Inrush Current
Zero Load
Power Consumption
Touch Current/
Leakage Current (typical)
Input
*visit www.iccus.com for complete details
5-YEAR LIMITED wARRANTY*
85 – 264VAC
100 – 240VAC Nominal
47 – 63Hz
<0.5A rms
<37A at 230VAC cold start
0.85W
<100µA @ 132VAC @ 60Hz
<200µA @ 264VAC @ 60Hz
Medical Switch Mode Power Supply
Output Voltage
Total Regulation
Minimum Load
Start-up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection
Output
MW24 Series
High Efficiency
Fully Regulated DC Output
Hold-up Time >20ms at full load
Safety Approval - EN60601-1 Class I
See Table
+/-5%
No minimum load required
<1s
>20ms
<1% pk-pk **
110-135%
Active - Recoverable; plus
Passive - Non Recoverable
120 - 180%
shutdown, auto-restart
(hiccup mode)
24 watts

Related parts for W2415-760F-NC-BK

W2415-760F-NC-BK Summary of contents

Page 1

... TECHNICAL SUPPORT wORLDwIDE 1-888-357-2280 saleselpac@iccus.com www.iccus.com EUROPE +44.1383.432920 saleseurope@iccus.com Input Input Voltage Input Frequency Input Current Inrush Current Zero Load Power Consumption Touch Current/ Leakage Current (typical) Notes *visit www.iccus.com for complete details **Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor. ...

Page 2

... Model Number Output Voltage MW2412-760-NC-BK 12.0V MW2415-760-NC-BK 15.0V MW2418-760-NC-BK 18.0V MW2424-760-NC-BK 24.0V Notes 1) Maximum peak load (28.8W) lasting 500ms with a maximum 10% duty cycle. 2) Includes initial setting, line regulation, load regulation, and thermal drift. 3) Typical at 115VAC (including output cable). General Avg Efficiency 81.5% @ 115VAC; ...