HFD3025L Eaton / Control Automation, HFD3025L Datasheet

no-image

HFD3025L

Manufacturer Part Number
HFD3025L
Description
Circuit Breaker; Therm/Mag; Hndl; Cur-Rtg 25A; Panel; 3 Pole; Vol-Rtg 277/125VAC/VDC
Manufacturer
Eaton / Control Automation
Type
Thermal/Magneticr
Datasheet

Specifications of HFD3025L

Actuator Type
Handle
Brand/series
C Series
Current, Rating
25 A
Dimensions
4.125"Wx6"Hx3.375"D
Mounting Type
Panel
Number Of Poles
3
Termination
Screw
Time, Trip
18 ms
Voltage, Rating
277/125 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
INTERRUPTING CAPACITY RATINGS
UL489 Interrupting Capacity Ratings
IEC 157-1 Interrupting Capacity Ratings (P1)
Circuit
Breaker
Type
ED
EDH
EDC
EHD
FDB
FD
HFD
FDC
HFDDC
Circuit
Breaker
Type
ED
EDH
EDC
FDB
FD
HFD
FDC
2-pole circuit breaker, or two poles of 3-pole circuit breaker.
Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
HFDDC is UL only and is not tested to other standards.
Interrupting rating is 35,000 amps at 600-volt Dc with 3 poles in series, for ungrounded systems only.
Dc ratings apply to substantially non-inductive circuits.
Number
of
Poles
2, 3
2, 3
2, 3
1
2, 3
2, 3, 4
1
2, 3, 4
1
2, 3, 4
2, 3, 4
3
Number
of
Poles
2, 3
2, 3
2, 3
2, 3, 4
1
2, 3, 4
1
2, 3, 4
2, 3, 4
100,000
200,000
100,000
200,000
100,000
200,000
100,000
200,000
240
Interrupting Capacity (Symmetrical Amperes)
Volts Ac (50/60 Hz)
Interrupting Capacity (Symmetrical Amperes)
Volts Ac (50/60 Hz)
220, 240
. . . . . .
. . . . . .
. . . . . .
. . . . . .
65,000
18,000
18,000
65,000
65,000
18,000
25,000
65,000
65,000
100,000
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
277
14,000
25,000
65,000
380, 415
. . . . . .
14,000
35,000
65,000
Dimensions, Inches (mm)
Approximate Shipping Weight, Lbs. (kg)
No. of Poles
1
2
3
4
Breaker
Type
ED, EDH,
EDC
EHD, FDB,
FD, HFD
FDC
HFDDC
100,000
100,000
480
440
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
14,000
14,000
25,000
65,000
. . . . . .
. . . . . .
. . . . . .
14,000
. . . . . .
35,000
. . . . . .
65,000
Number of Poles
1
2
(.907)
Width
1.375 (35)
2.75 (70)
4.125 (105) 6 (152)
5.5 (140)
600
500
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
14,000
18,000
25,000
35,000
14,000
18,000
25,000
35,000
2
3
(1.361)
3
(1.361)
3.25
(1.474)
Height
6 (152)
6 (152)
6 (152)
Volts Dc
Volts Dc
125
10,000
10,000
10,000
10,000
. . . . . .
. . . . . .
10,000
. . . . . .
10,000
. . . . . .
. . . . . .
. . . . . .
125
10,000
10,000
10,000
. . . . . .
10,000
. . . . . .
10,000
. . . . . .
. . . . . .
3
4.5
(2.041)
4.5
(2.041)
4.75
(2.155)
4.5
(2.041)
Depth
3.375 (86)
3.375 (86)
3.375 (86)
3.375 (86)
4
6
(2.721)
6.35
(2.880)
250
. . . . . .
. . . . . .
. . . . . .
. . . . . .
10,000
10,000
. . . . . .
10,000
. . . . . .
22,000
22,000
42,000
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
22,000
22,000
10,000
10,000
250
Series C
Molded Case
Circuit Breakers
F-Frame
10-225 Amperes
STANDARDS
Series C molded case circuit breakers are
designed to conform with the following
standards:
Conformance with these standards satisfies
most local and international codes, assum-
ing user acceptability and simplified appli-
cation.
Series C molded case circuit breakers equal
or exceed Federal Specification Classifica-
tion W-C-375b requirements for the particu-
lar class associated with the circuit breaker
frame being considered.
Australian Standard AS 2184, Molded
Case Circuit Breakers
British Standards Institution Standard BS
4752: Part 1, Switchgear and Control
Gear Part 1: Circuit Breakers
Canadian Standards Association
Standard C22.2 No. 5, Service Entrance
and Branch Circuit Breakers
International Electrotechnical Commis-
sion Recommendations IEC 157-1, Circuit
Breakers
Japanese T-Mark Standard Molded Case
Circuit Breakers
National Electrical Manufacturers
Association Standards Publication No.
AB1-1993, Molded Case Circuit Breakers
South African Bureau of Standards,
Standard SABS 156, Standard Specifica-
tion for Molded Case Circuit Breakers
Swiss Electro-Technical Association
Standard SEV 157-1, Safety Regulations
for Circuit Breakers
Underwriters Laboratories, Inc., Stan-
dard UL 489, Molded Case Circuit
Breakers and Circuit Breaker Enclosures,
including Marine Circuit Breakers File
E7819
Union Technique de l’Electricite Stan-
dard NF C 63-120, Low Voltage
Switchgear and Control Gear Circuit
Breaker Requirements
Verband Deutscher Elektrotechnike
(Association of German Electrical Engi-
neers) Standard VDE 0660, Low Voltage
Switchgear and Control Gear, Circuit
Breakers
®
Selection Data
29-120F
Page 1

Related parts for HFD3025L

HFD3025L Summary of contents

Page 1

... Series C Molded Case Circuit Breakers F-Frame 10-225 Amperes STANDARDS Series C molded case circuit breakers are designed to conform with the following standards: Australian Standard AS 2184, Molded Case Circuit Breakers British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: Circuit Breakers Canadian Standards Association Standard C22 ...

Page 2

... Selection Data 29-120F Page 2 Series C Molded Case Circuit Breakers, F-Frame, 10-225 Amperes CATALOG NUMBERING SYSTEM This information is presented only as an aid to understanding catalog numbers not to be used to build catalog numbers for circuit breakers. Circuit Breaker Catalog Numbers FDC 3 100 L Circuit Breaker ...

Page 3

... Selection Data 29-120F Page 4 Series C Molded Case Circuit Breakers, F-Frame, 10-225 Amperes THERMAL-MAGNETIC CIRCUIT BREAKERS Sealed Breakers with Non-interchangeable Trip Units Suitable for reverse feed use. Maximum 600 Vac Maximum, 250 Vdc Continuous 14 kAIC @ 600 Vac Ampere Type FDB Rating @ 40°C ...

Related keywords