SMX750 American Power Conversion (APC), SMX750 Datasheet

no-image

SMX750

Manufacturer Part Number
SMX750
Description
UPS; SMART-UPS; RACK; TOWER; LCD; 750VA; 120V; 600 WATTS
Manufacturer
American Power Conversion (APC)
Type
Networkr
Datasheet

Specifications of SMX750

Battery Type
Lead-Acid
Brand/series
SMX750
Capacity
750 VA
Color
Black
Communication
DB9, RJ11, RJ45, RS232, USB
Dimensions
432 H × 89 W × 490 D mm
Input Type
DB9, RS232, SmartSlot, USB
Interface
DB-9 RS-232, USB, Smartslot
Length, Cord
2.44 m
Mounting Type
Rack/Tower
Output Type
(6) NEMA 5-15R
Power, Rating
600 W
Time, Backup
14.2 min.
Voltage, Output
120 V
Voltage, Supply
480/750 W/VA
Weight
29.5 kg
Lead Free Status / Rohs Status
RoHS Compliant part
APC Smart-UPS X 750VA Rack/Tower
LCD 120V
Part Number: SMX750
Output
Input
Batteries & Runtime
Output Power Capacity
Nominal Output Voltage
Output Voltage Distortion
Output Frequency (sync to mains)
Crest Factor
Waveform Type
Output Connections
Nominal Input Voltage
Input Frequency
Input Connections
Cord Length
Input voltage range for main operations 82 - 143V
Input voltage adjustable range for mains
operation
Maximum Input Current
Input Breaker Capacity
Battery Type
Included Battery Modules
Available Battery Slots
Typical recharge time
RBC™ Quantity
DC Overcurrent Protection
Typical Backup Time
at Half Load
Typical Backup Time
at Full Load
Runtime Chart
Extended Run Options
600 Watts / 750 VA
120V
Less than 5%
47 - 63 Hz
3 : 1
Sine wave
120V
50/60 Hz +/- 3 Hz (auto sensing)
2.44 meters
75 - 154V
12A
15A
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
1
1
3 hour(s)
1
60A
37.8 minutes (300 Watts)
14.2 minutes (600 Watts)
Smart-UPS
APC Smart-UPS X 750VA Rack/Tower LCD 120V
(8) NEMA 5-15R
NEMA 5-15P

Related parts for SMX750

SMX750 Summary of contents

Page 1

... APC Smart-UPS X 750VA Rack/Tower LCD 120V Part Number: SMX750 Output Output Power Capacity Nominal Output Voltage Output Voltage Distortion Output Frequency (sync to mains) Crest Factor Waveform Type Output Connections Input Nominal Input Voltage Input Frequency Input Connections Cord Length Input voltage range for main operations 82 - 143V ...

Page 2

Energy Use/Efficiency Communications & Management Available SmartSlot™ Interface Quantity1 Control panel Audible Alarm Emergency Power Off (EPO) Surge Protection and Filtering Surge energy rating Filtering Physical Maximum Height Maximum Width Maximum Depth Rack Height Net Weight Shipping Weight Shipping Height ...

Page 3

Conformance Regulatory Approvals Standard Warranty Environmental Compliance **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS. Copyright © American Power Conversion ...

Related keywords