XW1E-BV411M-RH-EMO IDEC Corporation, XW1E-BV411M-RH-EMO Datasheet - Page 5

no-image

XW1E-BV411M-RH-EMO

Manufacturer Part Number
XW1E-BV411M-RH-EMO
Description
EMERGENCY STOP 22MM XW SERIES NON ILLUMINATED 1NO 1NC CONTACTS, SCREW TERMINALS
Manufacturer
IDEC Corporation
Type
Pushbuttonr
Datasheet

Specifications of XW1E-BV411M-RH-EMO

Actuator Type
Mushroom
Contact Form
1 NC/NO
Current, Rating
5/2 AAC/ADC
Dielectric Strength
250 V
Function
E-Stop
Mounting Hole Size
22.3 mm
Mounting Type
Panel
Operation
Push-Lock Turn-Reset
Termination
Screw
Voltage, Rating
250 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
X Series E-Stops
Removing the Contact Block
First unlock the operator button. Grab the bayonet ring j and pull back the
bayonet ring until the latch pin clicks k, then turn the contact block counter-
clockwise and pull out l.
Notes for removing the contact block
1. When the contact block is removed, the monitor contact (NO contact) is
2. While removing the contact block, do not exert excessive force, otherwise the
3. An LED lamp is built into the contact block for illuminated pushbuttons. When
Panel Mounting
Remove the locking ring from the operator and check that the rubber gasket is
in place. Insert the operator from panel front into the panel hole. Face the side
without thread on the operator with TOP marking upward, and tighten the lock-
ing ring using ring wrench MW9Z-T1 to a torque of 2.0 N·m maximum.
Notes for Panel Mounting
To prevent the XW emergency stop switch from rotating when resetting from
the latched position, use of an anti-rotation ring (HW9Z-RL) or a nameplate is
recommended.
closed.
switch may be damaged.
removing the contact block, pull the contact block straight to prevent damage
to the LED lamp. If excessive force is exerted, the LED lamp may be damaged
and fail to light.
Rubber Gasket
k Turn counterclockwise
j Grab
k Pull
Operator without thread
TOP marking
Locking Ring
j Grab
Bayonet Ring
Operating Instructions
Installing the Contact Block
First unlock the operator button. Align the small t marking on the edge of the
operator with the small s marking on the yellow bayonet ring. Hold the contact
block, not the bayonet ring. Press the contact block onto the operator and turn
the contact block clockwise until the bayonet ring clicks.
Notes for installing the contact block
Make sure that the bayonet ring is in the locked position. Check that the two
projections on the bayonet ring are securely in place.
Wiring
The applicable wire size is 16 AWG maximum.
q marking
Projections
j Push
p marking
Latched
XW Series
k Turn clockwise
Unlatched