GPFM115-28 SL Power ( Ault / Condor ), GPFM115-28 Datasheet

no-image

GPFM115-28

Manufacturer Part Number
GPFM115-28
Description
Power Supply, Single Output; 115 W; Single; 28 V; 2.9 A (Max.); 85 to 264 VAC;
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GPFM115-28

Brand/series
GPFM115 Series
Configuration
Open-Frame
Current, Input
1.7 A (Max.) @ 90 VAC, 60 Hz
Current, Leakage
90 uA @ 132 VAC, 60 Hz (Normal Condition), 250 uA @ 264 VAC (Single Fault Condition)
Current, Output
2.9 A (Max.)
Dimensions
5.25 in. L x 3.3 in. W x 1.5 in. H
Hold Time
25 ms minimum from loss of ac input at full load.
Mounting Type
Panel
Noise, Output
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.
Number Of Outputs
1
Operation
Switching
Output
28 VDC @ 4.1 A
Output Type
Single
Power Rating
115 W
Power, Output
115 W
Primary Type
AC-DC
Regulation, Total
2
Special Features
PFC, Remote Sense
Standards
CE Marked to LVD
Voltage, Input
85 to 264 VAC
Voltage, Output
18 VDC
AC Input
85-264 VAC, 47-63 Hz single phase.
Input Current
M aximum input current at 90 VAC, 60 Hz with full rated load is 1.7 A. Input
Inrush Current
I nrush 240 VAC is less than 37 A, averaged over the first AC halfcycle under
Input Protection
I nternal AC fuse provided on all models. Fuse does not blow on overload or
Leakage Current
9 0 μA normal conditions (132 VAC @ 60 Hz input) or 250 μA (264 VAC)
Output Power
Continuous rating is 80 W with unrestricted natural convection, or 115 W
DC Output Specification
T otal regulation is the maximum deviation from the nominal voltage for
Power Fail
T TL / CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
• 115 Watts of continuous power with forced air
• Power factor corrected
• 74-81% efficiency
• Small package 3.3” x 5.25” x 1.5” inches
• Power fail warning, remote sense
• Optional cover with cooling fan
• Medical Approval to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1
• RoHS Compliant Model Available (G suffix)
GPFM115 Medical
115 Watt Global Performance Switchers
International Safety Standard Approvals
Specifications
current harmonic content meets the requirements of IEC1000-3-2 for all load
conditions at 230 VAC input. Active input circuitry provides high power
factor of .96 min, .99 typical.
cold start conditions. Limiting provided by internal thermistors.
short circuit -- fuse blows only if a catastrophic failure occurs in the unit.
single fault.
with forced convection. All models capable of 110% of rated power for 60
sec., 10% duty cycle maximum.
all steady state loading conditions. Peak ratings are for 60 s maximum
duration, 10% duty cycle. Consult factory for application assistance.
drops more than 4% below nominal voltage upon loss of AC power. The
signal is factory set to trip before there is insufficient power stored in the
primary to sustain the output. Signal can sink 1.6 mA or source 400 μA at
2.7 V (Fan-out = 1).
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Voltage Adjustment
Main output ±5%.
Output Noise
0 .5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
Minimum Load
N o minimum load required to maintain output specifications. An abrupt
Transient Response
M ain Output 500 μs typical response time for return to within 0.5% of final
Hold-up Time
25 ms minimum from loss of AC input at full load.
Overload Protection
F ully protected against short circuit and output overload. Short circuit pro-
Overvoltage Protection
B uilt in on all models - See voltage and current chart for individual model
Remote Sense
P rovided as a standard feature on all models. Capable of compensating for
Thermal Shutdown
P rovided as a standard feature. Designed to protect unit from prolonged
2 Year Warranty
noise probe directly across output terminals of the power supply.
change in output current from > 90% to < 2% load may cause a false trigger-
ing of the power fail signal.
value for a 50% load step change, ∆i/∆t<0.2 A/μs. Maximum voltage devia-
tion is 3.5%.
tection is cycling type power limit. Recovery after fault is automatic. Consult
factory for specific condition limits.
output limits. When OVP fires, the output converter stops providing input
power to output. Output voltage decay is dependent upon loading.
0.25 V total of cabling losses.
over temperature.

Related parts for GPFM115-28

GPFM115-28 Summary of contents

Page 1

... GPFM115 Medical 115 Watt Global Performance Switchers • 115 Watts of continuous power with forced air • Power factor corrected • 74-81% efficiency • Small package 3.3” x 5.25” x 1.5” inches • Power fail warning, remote sense • Optional cover with cooling fan • ...

Page 2

... Model Suffix* Output Adjustment GPFM115-5 G 5.1 V GPFM115- GPFM115- GPFM115- GPFM115- GPFM115- GPFM115- Notes * Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Maximum continuous current rating for unrestricted convection cooling. B. Maximum continuous current rating with 150 LFM air or cover option. C. Add “-C” suffix for cover with fan option. General Specifications (continued from p. 1) Efficiency 74 to 81% depending upon model. Temperature Coefficient 0.03%/°C typical on all outputs. Fan Output A n additional 12 VDC (nominal 10.5 V), 100 mA output suitable for power- ing a DC fan is included in all models ...

Page 3

... GPFM115 Medical 115 Watt Global Performance Switchers Mechanical Specifications JI INPUT: (AMP P.C.B. HEADER P.N 640445-5) PIN 1) AC LINE PIN 2) = N/C PIN NEUTRAL PIN 4) = N/C PIN GROUND SIGNALS: J2 AMP P.C.B. HEADER P/N 640456-4 MATING CONNECTOR P/N 640621-4 PIN 1) POWER FAIL PIN 2) -SENSE ...

Related keywords