HE9Z-D3Y IDEC Corporation, HE9Z-D3Y Datasheet

no-image

HE9Z-D3Y

Manufacturer Part Number
HE9Z-D3Y
Description
Cover; Yellow; Rubber; UL Recognized, CSA Certified
Manufacturer
IDEC Corporation
Datasheet

Specifications of HE9Z-D3Y

Color
Yellow
Material, Body
Rubber
Standards
UL Recognized, CSA Certified
Lead Free Status / Rohs Status
RoHS Compliant part
HE3B
Key features include:
• 3 position funtionality (OFF – ON – OFF) as required for manual robotic control
• Provides a high level of safety based on human behavioral studies that deter-
• Contacts will not re-close when released from Off On (3 1)
• Multiple contacts for enhanced reliability
• Snap acting contacts from position 1 to 2
• Available with or without rubber cover
www.idec.com
mine personnel may squeeze OR let go when presented with a panic situation
(per IEC60204-1; 9.2.5.8)
Conforming to Standards
Approvals
Operating Temperature
Operating Humidity
Storage Temperature
Pollution Degree
Contact Resistance
Insulation Resistance
Impulse Withstand Voltage
Operating Frequency
Mechanical Life
Electrical Life
Shock Resis-
tance
Vibration Resis-
tance
Terminal
Recommended Wire Size
Solder Heat Resistance
Terminal Pulling Strength
Recommended Screw Torque
Degree of Protection
Conditional Short-Circuit Current
Recommended Short Circuit Protection
Weight
Circuit Opening Force
Safety Products
Operating Extremes
Damage Limits
Operating Extremes
Damage Limits
HE3B Series Pushbutton Assembly Enabling Switch
USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC
IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, CSA C22.2
No 14
ISO12100/EN292, IEC60204-1/EN60204-1, ISO11161/prEN11161,
ISO10218/EN775, ANSI/RIA R15.06
–25 to +60˚C (no freezing)
45 to 85% RH maximum (no condensation)
–40 to +80˚C (no freezing)
3
50m maximum (beginning stage)
Between live & dead metal parts:
Between positive & negative live parts:
1.5kV
1200 operations/hour
Position 1 2 1 million minimum
Position 1 2 3 1: 100 thousand minimum
100,000 minimum at rated load
100m/s
1000m/s
5 to 55Hz, applitude 0.5mm minimum
16.7Hz, applitude 1.5mm minimum
0.110” quick connect / solder terminal
0.5mm
260°C / 3 seconds maximum
20N minimum
0.68 to 0.88N • m
with rubber cover: IP65,
without rubber cover: IP40 (IEC 60529),
50A (125V)
125V/10A fast blow fuse (IEC 60127-1)
without rubber cover - Approx. 14g
with rubber cover - Approx. 18g
500N minimum
100M maximum (at 500VDC mega)
100M minimum (at 500VDC mega)
2
2
maximum / 1 line
2
HE3B Series
B-45
B

Related parts for HE9Z-D3Y

HE9Z-D3Y Summary of contents

Page 1

Safety Products HE3B Series Pushbutton Assembly Enabling Switch HE3B Key features include: • 3 position funtionality (OFF – ON – OFF) as required for manual robotic control • Provides a high level of safety based on human behavioral studies that ...

Page 2

... Circuit Diagrams OFF 2. Use a lock nut tool to screw on the lock nut (see page B–47 retain the switches waterproof performance, do not penetrate the positioning hole. 4. Remove the rubber cover projection if you do not want a positioning hole. (Do not penetrate the rubber cover). USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC ...

Page 3

... Anti-Rotation 14.5 Ring 12.3 8.5 Solder Terminal 2.8x0. Part Numbers: Replacement Rubber Cover Appearance Part Number Material Silicon HE9Z-D3 Rubber www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Operating Characteristics Position 1 0.7 Part A 0 0.8 0.2 0.7 Part B 0 2.3 ...

Page 4

... Safety Products General Information for Enabling Switches • In order to avoid electric shock or fire, turn power off before installa- tion, removal, wire connection, maintenance or inspection of switch. • Follow specification when installing. Improper electrical load may damage switch, cause electric shock, or fire. ...

Page 5

Emergency Stop Pushbuttons Pushlock Turn Resets B (see page A38 for more information) (see page A75 for more information) HW1B ø • ø29 mm red button • Mounting hole: ø22.3 mm • 1NO-1NC,1NC, 1NO-1NC, or 2NC contacts • ...

Related keywords