VBA40A-T04GN-Z SMC Corporation, VBA40A-T04GN-Z Datasheet

no-image

VBA40A-T04GN-Z

Manufacturer Part Number
VBA40A-T04GN-Z
Description
BOOSTER REGULATOR, 1/2 NPTF, HANDLE OPERATED, PRESSURE GAUGE, PSI, SILENCER
Manufacturer
SMC Corporation
Datasheet

Specifications of VBA40A-T04GN-Z

Brand/series
VBA Series
Flow Rate
1900 SCFM
Pressure Adjustment
Handle Operating
Pressure Increase Ratio
Twice
Pressure, Operating
1 MPa
Proof Pressure
1.5 MPa
Size, Port
1⁄2 in.
Temperature, Ambient
2 to 50
Thread Type
NPTF
Lead Free Status / Rohs Status
RoHS Exempt Product
Series
Increase factory air pressure by up to twice
as much! No need for an electrical supply!
• Using air from a factory supply line increases pressure by up to twice as much.
• Space-saving air tank and booster regulator can be connected directly.
Increase factory air pressure by up to twice
as much! No need for an electrical supply!
(Fourfold pressure at the maximum with the VBA1111)
Booster regulator assists supplying more pressure where
Booster regulator assists supplying more pressure where
force is insufficient due to low factory pressure (for energy-
force is insufficient due to low factory pressure (for energy-
saving measures).
saving measures).
Booster
Booster
Regulator
Regulator
Compressor
Series
New
Factory line
VBA/VBAT
Air-operated type
0.3
VBA22A/42A
MPa
Series
Series
0.3
0.3
0.3
MPa
MPa
MPa
VBA
VBA
Boost pressure
Booster Regulator + Air Tank
RoHS compliant
New
Air Tank
Air Tank
Light
Light
Max. operating pressure
Series
0.6
MPa
Series
Series
VBA43A
Heavy
VBAT
VBAT
CAT.ES11-96B
1.6
MPa

Related parts for VBA40A-T04GN-Z

VBA40A-T04GN-Z Summary of contents

Page 1

Increase factory air pressure twice Increase factory air pressure twice as much! No need for an electrical supply! as much! No need for an electrical supply! • Using air from a factory supply line ...

Page 2

Booster Regulator Booster Regulator b Improved service life: that of conventional model • Floating piston structure (PAT. PEND) • Grease retaining groove Floating structure b Improved reliability: Built-in mesh filter at IN port • Prevent operation failure due to foreign ...

Page 3

Example of Circuit Diagram Energy and cost saving booster regulator for factory (Low pressure)> Example of Application When certain equipment requires a higher pressure than the factory line pressure. When the lower pressure limit for equipment must be en- sured ...

Page 4

... G N NPT T NPTF 40A 04 GN VBA Body size 3/8, Handle-operated type 1/2, Handle-operated type 3/8, Air-operated type 1/2, Air-operated type 1/2, Max. operating pressure 1.6 MPa VBA40A-04 VBA43A- Option Symbol Option Nil None G Pressure gauge N Silencer GN Pressure gauge, Silencer Port size ...

Page 5

... AMC510-06 VBA Twice Note 1) 1600 0.2 to 1.6 2.4 1/2 1/8 8.6 VBA43A-04 VBA43A-F04 KT-VBA43A-7 AN400-04 ANA1-04 ∗ VBA43A-N04 ∗ VBA43A-T04 ∗: when “ -Z ” KT-VBA43A-7N KT-VBA43A-8N — AN400-N04 ANA1-N04 For VBA40A-04 For VBA42A-04 For VBA43A-04 VBAT20„ VBAT38„ AM550C-06, 10 AMC610-10 2 ...

Page 6

VBA Series VBA1110 Flow Characteristics Outlet air flow (l/min (ANR)) Pressure Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Characteristics Flow rate /min (ANR) Set point Inlet pressure (MPa) Charge Characteristics Pressure increase ratio ...

Page 7

... Inlet pressure (MPa) Charge Characteristics 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 Pressure increase ratio VBA40A, 42A b The time required to charge tank pressure from 0.8 MPa to 1.0 MPa at 0.5 MPa supply pressure: P 0 2.0 P 0 With the pressure increase ratio from 1.6 to 2.0, the charge time of 3.5 – ...

Page 8

VBA Series Sizing (Sizing can be achieved by using SMC Pneumatic System Energy Saving Program Ver. 3.1. Please contact your SMC sales representative START Necessary conditions: D [mm]: Cylinder bore size L [mm]: Cylinder stroke W [mm/s]: Cylinder ...

Page 9

... Make sure to refer to the procedure for maintenance. Booster Regulator Booster Regulator VBA1110, VBA20A, 40A, 43A Governor Drive Booster chamber A chamber A Booster chamber A Piston Switching valve E OUT (Outlet) VBA20A, 22A, VBA40A, 42A, 43A VBA20A-03 0 VBA111 -02 1 VBA22A-03 KT-VBA1110-2 KT-VBA20A-1 VBA20A-03 0 VBA111 -02 ...

Page 10

... Gauge port Rc 1/16 OUT 150 60 IN OUT 40 50 VBA20A-03 300 39 IN side gauge port Rc 1 VBA40A-04 404 40 IN side gauge port Rc 1/8 96 116 7 Gauge port Rc 1/16 IN Pressure gauge (Option) G27-20-R1 Pressure gauge (Option) OUT side gauge port Rc 1/8 Pressure gauge (Option) ...

Page 11

Dimensions VBA22A-03 300 39 IN side gauge port Rc 1/8 53 73.00 VBA42A-04 404 40 IN side gauge port Rc 1/8 96 116 VBA43A-04 404 40 IN side gauge port Rc 1/8 96 116 Pressure gauge (Option) OUT side gauge ...

Page 12

Air Tank Series Made to Order Symbol Specifications Nil Standard 20 Copper-free/Fluorine-free (Refer to page 15.) • Compact connections are possible with booster regulators. • It can be used alone as a tank. • Also compatible with overseas standards (Refer ...

Page 13

List of Air Tank for Overseas The pressure vessel law is different from country to country air tank suitable to a country needs to be manufactured. Please select from the below table. For details on all products except ...

Page 14

VBAT Series Dimensions: VBAT05A, 10A (Material: Carbon Steel) VBAT05A Connected to VBA1110 Safety valve port Rc 3/8 Inspection port 1/2 Tank OUT port Rc 3/8 32 VBAT10A Connected to VBA1110 Safety valve port Rc 3/8 Inspection port ...

Page 15

... Rc 1/2 Connected to VBA22A, 42A Booster regulator IN port C C EXH: OUT 4 x ø13 150 150 250 250 VBA20A 531 444 Rc 3/8 VBA40A 570 480 Rc 1/2 VBA22A 495 444 Rc 3/8 VBA42A 528 480 Rc 1/2 ø18 EXH ø13 (mm) D Note) — ...

Page 16

VBAT Series Dimensions: VBAT05S, 10S (Material: Stainless Steel 304) VBAT05S Connected to VBA1110 Tank OUT port Rc 3/8 32 VBAT10S Connected to VBA1110 Tank OUT port Rc 1/2 32 Drain port Rc 1/4 Connected to VBA20A Tank IN port Rc ...

Page 17

... Connected to VBA22A, 42A, 43A Booster regulator IN port C C EXH: OUT 4 x ø13 150 150 250 250 VBA20A 531 444 Rc 3/8 VBA40A 570 480 Rc 1/2 VBA22A 495 444 Rc 3/8 VBA42A 528 480 Rc 1/2 VBA43A 576 — — C EXH ø13 (mm) D Note) — ...

Page 18

VBA Series Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. 1 Copper-free/Fluorine-free The inner or outer copper parts material has been changed to stainless steel or aluminum. The fluorine resin parts has been changed to ...

Page 19

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be ...

Page 20

Safety Instructions The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a ...

Page 21

VBA Series Specific Product Precautions 1 Be sure to read this before handling. Refer to back pages 1 and 2 for Safety Instructions and “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Booster Regulator/Specific Product Precautions Design Warning 1. ...

Page 22

VBA Series Specific Product Precautions 2 Be sure to read this before handling. Refer to back pages 1 and 2 for Safety Instructions and “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Booster Regulator/Specific Product Precautions Piping Caution 1. ...

Page 23

VBA Series Specific Product Precautions 3 Be sure to read this before handling. Refer to back pages 1 and 2 for Safety Instructions and “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Booster Regulator/Specific Product Precautions Handling Caution 3. ...

Page 24

... Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com © 2008 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Record of changes ∗ The addition of air-operated type booster regulators, ...

Related keywords