WM14-96AV63CX Carlo Gavazzi, Inc., WM14-96AV63CX Datasheet

no-image

WM14-96AV63CX

Manufacturer Part Number
WM14-96AV63CX
Description
Energy Meter, Power Analyzer, 3-Phase, 100/208VAC Input Range, 115VAC Supply
Manufacturer
Carlo Gavazzi, Inc.
Datasheet
• Optional dual pulse output
• Alarms (visual only) V
• Optional galvanically insulated measuring inputs
Product Description
3-phase power analyzer with
built-in programming key-
pad. Particularly recom-
mended for displaying the
main electrical variables.
Housing for panel mounting,
Type Selection
Range codes
AV5: 380/660V
AV6: 120/208V
Phase current: 0.03A to 6A
Neutral current: 0.09 to 6A
Rated inputs
Accuracy (display, RS485)
Input specifications
Specifications are subject to change without notice
Energy Management
Power Analyzer
Type WM14-96 “Basic Version”
Current “X-S options”
Current “SG-PG options”
Voltage
(@25°C ±5°C, R.H. ≤60%)
Current
Neutral current
Phase-phase voltage
Phase-neutral voltage
Active and Apparent power,
Reactive power
VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
L-L
L-L
/5(6)AAC
/5(6)AAC
LN
, An
(front) protection degree
IP65, and optional RS485
serial port or dual pulse out-
put. Parameters pro-
grammable by means of
CptBSoft.
System
3 :
3 (non insulated each other)
3 (insulated each other)
4
with CT=1 and VT=1 AV5:
1150W-VA-var, FS:230VLN,
400VLL; AV6: 285W-VA-var,
FS:57VLN, 100VLL
0.25 to 6A: ±(0.5% FS +1DGT)
0.03A to 0.25A: ±(0.5%FS+7DGT)
0.25 to 6A: ±(1.5% FS +1DGT)
0.09A to 0.25A: ±(0.5%FS+7DGT)
±(1.5% FS +1 DGT)
±(0.5% FS + 1 DGT)
0.25 to 6A: ±(1% FS +1DGT);
0.03A to 0.25A: ±(1% FS
+5DGT)
0.25 to 6A: ±(2% FS +1DGT);
1-2-3-phase,
balanced/unbalanced
load,with or without
neutral
WM14-96DS 310706
How to order
Model
Range code
System
Power supply
Option
How to order
Additional errors
Temperature drift
Sampling rate
Display refresh time
Display
• Class 1 (active energy)
• Class 2 (reactive energy)
• Accuracy ±0.5 F.S. (current/voltage)
• Power analyzer
• Display of instantaneous variables: 3x3 digit
• Display of energies: 8+1 digit
• System variables and phase measurements: W, W
• A
• Energy measurements: kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC
• Protection degree (front): IP65
• Front dimensions: 96x96mm
• Optional RS422/485 serial port
CptBSoft (compatible only with S or SG options): software
to program the working parameters of the power analyzer
and to read the energy and the instantaneous variables.
Power supply
A:
B:
C:
D:
3:
Active energy “X-S option”
Reactive energy “X-S option”
Active energy “SG-PG opt.”
Reactive energy “SG-PG opt.”
Frequency
Humidity
Type
Read-out for instant. var.
Read-out for energies
var, VA, VA
max
, A
24VAC
-15+10%, 50-60Hz
48VAC
-15+10%, 50-60Hz
115VAC
-15+10%, 50-60Hz
230VAC
-15+10%, 50-60Hz
18 to 60VDC (not
available in case of
SG or PG options)
dmd max
dmd
, W
, PF, V, A, An, A
dmd max
WM14-96 AV5 3 D
CptBSoft
indication
dmd
Options
X:
S:
SG:
PG:
0.03A to 0.25A: ±(2% FS +5DGT)
Class 2 (start up “I”: 30mA)
Class 3 (start up “I”: 30mA)
Class 1 (start up “I”: 30mA)
Class 2 (start up “I”: 30mA)
±0.1Hz (48 to 62Hz)
≤0.3% FS, 60% to 90% RH
≤ 200ppm/°C
1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
700ms
LED, 14mm
3x3 DGT
3+3+3 DGT (Max indication:
999 999 99.9)
, Hz
None
RS485 port
RS485+galvanic insu-
lated measurig inputs
Dual pulse output +
galvanically
measuring inputs.
insulated
PGX
dmd
,
1

Related parts for WM14-96AV63CX

WM14-96AV63CX Summary of contents

Page 1

... Energy Management Power Analyzer Type WM14-96 “Basic Version” • Optional dual pulse output • Alarms (visual only • Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer with (front) protection degree built-in programming key- IP65, and optional RS485 pad. Particularly recom- ...

Page 2

... PC (RS232); By means of RS485 serial port. 5 Electrical life: min 2*10 cycles 6 Mechanial life: 5*10 cycles ≥100ms <120ms (ON) ≥100ms (OFF) According to EN622053-31 By means of relays, 4000 V outputs to RMS measuring inputs, 4000 V output to RMS supply input. Insulation between the two outputs: 1000V RMS WM14-96 DS 310706 ...

Page 3

... Specifications are subject to change without notice Alarms Reset A L3 dmd Power consumption Dielectric strength EMC Emissions WM14-96DS 310706 Page 5: An, An Alarm Page 6: W L1 Page 7: PF L1 Page 8: var L1, var L2, var L3 Page 9: VA L1 Page 10: VA ∑, W ∑, var ∑ Page 11: VA dmd, W dmd, Hz ...

Page 4

... The total indication is given in max 3 groups of 3 digits. AL.U= is activated only if one of VLN is not within the set limits. max. current among the three phases max. dmd current among the three phases hour counter var dmd WM14-96 DS 310706 ...

Page 5

... Class 3 accuracy limits (Reactive energy) 5(6A) Start-up current: 30mA Instantaneous apparent power Instantaneous reactive power System variables Equivalent 3-phase voltage 3-phase reactive power WM14-96DS 310706 Figure C Sine wave, distorted Fundamental content 0...90% Harmonic content Frequency spectrum: 3rd to 16th harmonic Additional error: <0.5% FS ...

Page 6

... Specifications are subject to change without notice Fig. 2 ARON and VT connection Fig. 5 1-phase connection WM14-96 DS 310706 Fig. 3 Fig. 6 ...

Page 7

... To program the configuration parameters and the display of the variables Key to enter programming and confirm selections Keys to: - programme values; - select functions; - display measuring pages. 2. Display 1 LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 15.4mm 61.4mm WM14-96DS 310706 1314 3 1 91mm Fig ...

Related keywords