Circuit Breaker; Therm/Mag; Hndl; Cur-Rtg 90A; Panel; 3 Pole; Vol-Rtg 415, 480VAC
Manufacturer
Eaton / Control Automation
Type
Thermal/Magneticr
Datasheet

Specifications of EGE3090FFG

Actuator Type
Handle
Brand/series
G Series
Current, Rating
90 A
Dimensions
3"Wx5.5"Hx2.99"D
Mounting Type
Panel
Number Of Poles
3
Termination
Box
Time, Trip
50 ms
Voltage, Rating
415, 480 VAC
General Information
Cutler-Hammer Series G Molded Case
Circuit Breakers provide increased
performance in considerably less
space than standard circuit breakers
or comparable fusible devices.
The “G” signifies global applications:
Series G circuit breakers are marked
with UL, CSA, CE, IEC and KEMA KEUR
listings. Other advantages include:
The EG, JG and LG frames are
designed around space-saving foot-
prints. The NG and RG use the proven
Cutler-Hammer Series C ND and RD
designs but use metric threading on
their line and load conductors.
Cutler-Hammer Series G Circuit
Breakers meet applicable UL 489
and IEC 60947-2 standards.
The Cutler-Hammer Series G family
includes five frame sizes in ratings
from 15 to 2500 amperes. Series G
offers a choice of several interrupting
capacities up to 200 kA at 480 volts ac
(200 kA at 240 volts ac).
Standard calibration is 40°C. For appli-
cations in high ambient temperature
conditions, 50°C factory calibration
is available on thermal magnetic
breakers (not UL).
CA08102001E
Field-fit accessories.
Common accessories through
630 amperes.
Electronic trip units from 20 to
2500 amperes.
UL-listed and IEC-rated, 30 mA
ground fault/earth leakage modules.
Built-in ground fault protection
down to 20 amperes.
The Most Logically Designed
Contact Assembly
The flexibility and outstanding
performance characteristics of Cutler-
Hammer Circuit Breakers are made
possible by the best contact designs
in circuit breaker history. Our patented
technology creates a high-speed
“blow-open” action using the
electromechanical forces produced
by high-level fault currents.
Cutler-Hammer Circuit Breakers are
operated by a toggle-type mechanism
that is mechanically trip-free from
the handle so that the contacts cannot
be held closed against short circuit
currents. Tripping due to overload or
short circuits is clearly indicated by the
position on the handle. This remark-
ably fast and dependable contact
action is designed to enhance safety.
Thorough In-Plant Testing
The quality, dependability and reliability
of every Cutler-Hammer Circuit Breaker
is ensured by a thorough program
of in-plant testing. Two calibration
tests are conducted on every pole of
every circuit breaker to verify the trip
mechanism, operating mechanism,
continuity and accuracy.
ISO Certification
Cutler-Hammer Circuit Breakers
are manufactured in ISO certified
facilities.
Circuit Breakers & Supplementary Protectors
15 – 2500 Amperes for UL, CSA & IEC Applications
Product Line Overview
Current Limiting Characteristics
Circuit breakers are current limiting
because of their high repulsion contact
arrangement and use of state-of-
the-art arc extinguishing technology.
Eaton offers one of the most
complete lines of current limiting
breakers in the industry. The industrial
breakers are available in current
limiting versions with interrupting
capacities up to 200 kA at 480 V
without fuses in the same physical size
as standard and high interrupting
capacity breakers.
Operating Mechanisms
Cutler-Hammer Circuit Breakers have
a toggle handle operating mechanism,
which also serves as a switching
position indicator. The indicator shows
the positions of: ON, OFF and TRIPPED.
The toggle handle snaps into the
TRIPPED position if the breaker is
tripped by one of its overcurrent, short
circuit, shunt or undervoltage releases.
Before the circuit breaker can be
reclosed following a trip-out, the tog-
gle handle must be brought beyond
the OFF position (RESET). The circuit
breaker can then be reclosed.
As an additional switching position
indicator for EG- to RG-Frame circuit
breakers, there are two windows on
the right and on the left of the toggle
handle, in which the switching state
is indicated by means of the colors
red, green and white corresponding to
the ON, OFF and TRIPPED positions
respectively.
Figure 45-2. Positions of the Toggle
Handle Drive
OFF
RESET
ON
Tripped
45-3
45

Related parts for EGE3090FFG

EGE3090FFG Summary of contents

Page 1

... Circuit Breakers provide increased performance in considerably less space than standard circuit breakers or comparable fusible devices. The “G” signifies global applications: Series G circuit breakers are marked with UL, CSA, CE, IEC and KEMA KEUR listings. Other advantages include: ■ Field-fit accessories. ...

Page 2

... UL 489, as well as CSA C22.2 No. 5-02. KEMA, UL and CSA provide ongoing follow-up testing and inspections to ensure that Cutler-Hammer Molded Case Circuit Breakers continue to meet their exacting standards. General Information Eaton’s electrical business, under the Cutler-Hammer brand, offers the widest variety of molded case circuit breakers available today ...

Page 3

... EG breaker rated 600/347 Vac. Two poles in series. Not suitable for dc application. 4-pole ground fault not available. 125 Vdc only for 1-pole breakers. CA08102001E Circuit Breakers & Supplementary Protectors 15 – 2500 Amperes for UL, CSA & IEC Applications Frame Sizes EG through LG JG 250 ...

Page 4

... At 40°C – At 50°C – At 55°C – At 60°C – At 70°C Rated Short Circuit Breaking Capacity (dc) Not for Circuit Breakers for Motor Protection (Time Constant = 10 rms) 2 Conducting Paths in Series For 250 Vdc NEMA (Time Constant = 8 rms) 2 Conducting Paths in Series ...

Page 5

... Circuit Breakers & Supplementary Protectors 45-8 15 – 2500 Amperes for UL, CSA & IEC Applications Frame Sizes EG through RG Table 45-3. EG through RG Electrical Characteristics (Continued) Technical Data Conductor Cross Sections and Terminal Types for Main Conductors ■ Solid or Stranded ■ Finely Stranded with End Sleeve ■ ...

Page 6

... Vdc Maximum Load Duration Maximum Opening Time Molded Case Switch (with High Magnetic Trip) Unfused kAIC at 480 Vac (415 Vac) Self-Protected, Will Trip Above: CA08102001E Circuit Breakers & Supplementary Protectors 15 – 2500 Amperes for UL, CSA & IEC Applications Frame Sizes EG through ...

Page 7

... Circuit Breakers & Supplementary Protectors 45-14 15 – 125 Amperes EG-Frame EG-Frame Eaton’s Cutler-Hammer EG Product Description ■ EG breaker is HACR rated. 45 Technical Data and Specifications Table 45-6. UL 489/IEC 60947-2 Interrupting Capacity Ratings Circuit Number Interrupting Capacity (Symmetrical Amperes) (kA) Breaker of Poles Volts ac (50/60 Hz) Type 120 220 – ...

Page 8

... C 35 100 100 200 K Molded Case Switch Cannot be UL rated. Available only as 125 and 160 A sizes. CA08102001E Circuit Breakers & Supplementary Protectors 15 – 125 Amperes EG-Frame 015 FF G Poles Amperes 016 015 020 M = Metric End Caps 025 E = Imperial End Caps ...

Page 9

... EGE3040AFG EGE4040FFG EGE3045FFG EGE3050AFG EGE4045FFG EGE3050FFG — EGE4050FFG EGE3060FFG — EGE4060FFG EGE3063FFG EGE3063AFG EGE4063FFG EGE3070FFG — EGE4070FFG EGE3080FFG EGE3080AFG EGE4080FFG EGE3090FFG — EGE4090FFG EGE3100FFG EGE3100AFG EGE4100FFG EGE3125FFG EGE3125AFG EGE4125FFG EGS3015FFG — EGS4015FFG EGS3016FFG — EGS4016FFG EGS3020FFG — EGS4020FFG EGS3025FFG EGS3025AFG EGS4025FFG EGS3030FFG — ...

Page 10

... Change the fourth digit to 7 for 100% neutral protection. Neutral side. Table 45-11. Molded Case Switches Catalog Number EGK2125KSG EGK3125KSG EGK4125KSG Note: Molded case switches may open above 1250 A. CA08102001E Circuit Breakers & Supplementary Protectors 15 – 125 Amperes EG-Frame 3-Pole Fixed Adjustable Thermal Thermal Fixed Fixed ...