FC5A-D12S1E IDEC, FC5A-D12S1E Datasheet

no-image

FC5A-D12S1E

Manufacturer Part Number
FC5A-D12S1E
Description
MicroSmart Pentra 12 I/O CPU With Ethernet Port, Transistor Source Outputs
Manufacturer
IDEC
Datasheet

Specifications of FC5A-D12S1E

Supply Voltage Range
20.4VDC To 26.4VDC
Memory Type
Flash
The New
MicroSmart Pentra PLC Family

Related parts for FC5A-D12S1E

FC5A-D12S1E Summary of contents

Page 1

The New MicroSmart Pentra PLC Family ...

Page 2

... Safety All MicroSmart Pentra PLCs meet the highest standards for safety including: cULus listed for Class 1 Division 2 hazardous locations*, CE compliant, as well as certified for marine use by ABS, DNV, and Lloyd’s Registry*. *Not applicable for all models. Visit www.IDEC.com/approvals for details. 2 ...

Page 3

The MicroSmart Pentra PLC Family: Everything you need in a controller Embedded Ethernet Port Modbus TCP, RTU and ASCII Seven communication ports User web page Setting the standards for automation…again Email and text notifications USB programming port NEW Advanced PID ...

Page 4

... Choose a CPU for every application With three controller types to choose from, MicroSmart Pentra PLCs offer the features you need for your applications. Built to allow you the flexibility to expand when you need to, MicroSmart Pentra PLCs are the best way to get everything you need in just one controller. ...

Page 5

DC Analog Input Potentiometer (8-bit resolution) Screw Terminal or MIL connector termination Slim CPU If you don’t need Ethernet, but still want a high-performance CPU, the MicroSmart Pentra slim CPU is your best choice! Available with 24V DC power, ...

Page 6

... Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. All IDEC MicroSmart Pentra PLCs support Modbus protocol. Using intuitive WindLDR software, you can configure the MicroSmart Pentra Master or Slave device on a Mod- bus network ...

Page 7

Modbus Connectivity with TCP, RTU and ASCII WindLDR Software Monitor & Update Program SCADA Supervisory Controls Modbus TCP Client Modbus RTU and ASCII For standard MicroSmart Pentra PLCs communica- tion ports can be configured as Modbus RTU ...

Page 8

... It makes sense: you can’t always be in the same location as your machinery, but with IDEC MicroSmart Pentra PLCs, you don’t need to be. Now you can monitor status in real-time, receive email alerts and customize your own web pages ...

Page 9

Simultaneous Connections Using Maintenance Communication Server connections Client devices, such touchscreen, WindLDR software and SCADA OPC server such as WindSRV (KepServerEx), can simultaneously communicate with your MicroSmart Pentra PLC. Using Server ...

Page 10

... Customize critical data for quick online monitoring Using the MicroSmart Pentra PLC with embedded Ethernet, you have the ability to design and create your own web page. Using a standard web browser, such as Internet Explorer or Firefox, critical information in the PLC can be ac- cessed and controlled remotely over the web ...

Page 11

... Reliable cellular connections • 24/7 monitoring • Alarms and system status alerts • Remote updating for PLC programs Setting the Standards for Connectivity Cellular Modem Internet Server IDEC OI Touchscreen 11 ...

Page 12

... Modbus protocol. You can configure one port to talk Modbus RTU master, another port for Modbus RTU slave, and more. Network thousands of I/Os Using IDEC Datalink and/or Modbus protocol, you can configure tens of thousands of I/Os with one MicroSmart Pentra PLC. Port 6 ...

Page 13

Boost the speed of productivity The success of your system might be dependent on a few milliseconds. Many micro controllers lack the necessary tools for accuracy at any speed, much less at the high speeds modern applications require. MicroSmart PLCs ...

Page 14

... Revolutionary universal input module IDEC also offers a universal analog input module. This 4-pt universal analog input module can accept any of the following types of analog signals: 4-20 mA, 0-10V DC, RTD and type thermocouple! Easy to Configure and Scale Setting up analog modules in your PLC system should not be a challenge ...

Page 15

Advanced PID for precision control PID (Proportional Integral Derivative) is the most commonly used feedback control loop in industrial control systems. PID calculates an error value as the difference between a mea- sured process variable and a desired set point. ...

Page 16

... Solar ready 12V DC models With abundant features and unparalleled performance, 12V DC MicroSmart Pentra PLCs are the perfect choice for solar applications, including traffic signs, light controls, road sign controls, remote pumping and injections systems for oil and gas industries, remote water pumping stations and solar tracking systems ...

Page 17

... Meets rigorous maritime standards IDEC MicroSmart Pentra PLCs are one of the few PLCs in the market approved for maritime applications. Our PLCs are widely used in both marine and offshore applications. We are dedicated to ensuring the safety of life and property at sea. Our MicroSmart Pentra PLCs are trusted and ap- ...

Page 18

... WindSRV, also known as KEPServerEX OPC server that provides direct connectivity between client applications and IDEC MicroSmart Pentra PLCs. It’s a true plug-and-play OPC Server with effortless data management, acquisition, monitoring and control. Plus it supports complete addressing, including 32-bit data and floating point data ...

Page 19

... LOD instructions 0.056 MOV instructions 0 0.5 IDEC MicroSmart Pentra Setting the Standards for Performance Expanded Memory You won’t run out of program memory space with our Mi- croSmart Pentra PLCs. The slim type CPU supports up to 62K bytes (10,400 steps) of programming memory. And if that’s ...

Page 20

... AO boasts a completely new graphic user interface and redesigned menu icons one-stop automation software package for IDEC MicroSmart Pentra PLCs and IDEC OI touchscreens, and is compatible with Windows XP, Vista (32 bit) and Windows 7 (32 and 64-bit). FREE Upgrades The Automation Organizer suite comes with free lifetime upgrades ...

Page 21

... A workspace is available to help you organize and manage projects, objects and screens. WindCFG is a system layout and configuration tool for IDEC PLCs and OI touchscreens. Using WindCFG, you can create a visual layout of the system design and basic configuration of your PLC and OI touchscreens. ...

Page 22

... Part Numbers Slim CPUs Appearance Part Number FC5A-D12K1E FC5A-D12S1E FC5A-D16RK1 FC5A-D16RS1 FC5A-D32K3 FC5A-D32S3 All-in-One CPUs Appearance Part Number FC5A-C10R2 FC5A-C10R2C FC5A-C10R2D FC5A-C16R2 FC5A-C16R2C FC5A-C16R2D FC5A-C24R2 FC5A-C24R2C FC5A-C24R2D 22 Embedded I/Os Operating Voltage Ethernet & USB Port 12 (8in/4out) Yes 16 (8in/8out) 24V DC — ...

Page 23

... DC, 4-20mA - 0-10V DC, 4-20mA Web Server Module Appearance Part Number FC4A-EnET RS232C/RS485 Communication Modules Appearance Part Number FC5A-SIF4 FC5A-SIF2 Connection Type Removable Screw Terminal MIL Connector Removable Screw Terminal MIL Connector Removable Screw Terminal Spring Clamp I/O Points Resolution 8 (8 inputs) ...

Page 24

... Expansion Power Supply Modules Appearance Part Number Description Master expansion power supply FC5A-EXM1M (Use with FC5A-EXM1S slave power supply) Slave expansion power supply FC5A-EXM1S (Use with FC5-EXM1M master power supply) Expansion interface cable between master and FC5A-KX1C slave power supply (1m length) ...

Page 25

... Specifications Slim CPU FC5A-D12K1E Part Number FC5A-D12S1E Rated Power Voltage Allowable Voltage Range Maximum Input Current Maximum Power Consumption Allowable Momentary Power Interruption Dielectric Strength Insulation Resistance Between power and Noise Resistance Inrush Current Power Supply Wire Operating Temperature Storage Temperature ...

Page 26

... User web page area: 1 MB, Authentication: Basic Authentication, Compliant browser: Internet Explorer 7 & 8, Firefox 3 PING number of remote hosts can be registered: 255 *1: If the email address length is 40 characters, 12 email addresses can be configured. 26 FC5A-D12K1E FC5A-D16RK1 FC5A-D12S1E FC5A-D16RS1 Stored program system 42 basic, 152 advanced 42 basic, 126 advanced 127.8KB (21,300 steps) 83µs (1,000 steps) ...

Page 27

... Not including expansion I/O service time, clock function processing time, data link processing time, and interrupt processing time. *3: Expansion modules cannot be connected to FC5A-C24R2D. Notes: The maximum number of relay outputs that can be turned on simulatneously is 33 including those on the CPU module. ...

Page 28

... Tel: +61-3-8523-5900 sales@au.IDEC.com Specifications and other descriptions in this catalog are subject to change without notice. If you’re looking to improve your knowledge of IDEC PLCs and OI touchscreens, IDEC training courses take a hands-on approach using real world examples to enhance your learning and retention. We are confident you will walk out of our class able to program, debug and maintain IDEC automation systems ...