6.716.010.000 KÜBLER, 6.716.010.000 Datasheet

COUNTER, PRESET, 90-260VAC, 716

6.716.010.000

Manufacturer Part Number
6.716.010.000
Description
COUNTER, PRESET, 90-260VAC, 716
Manufacturer
KÜBLER
Datasheet

Specifications of 6.716.010.000

No. Of Digits / Alpha
6
Digit Height
8mm
Supply Voltage Range
90VAC To 250VAC
Power Consumption
5VA
Operating Temperature Range
-10°C To +50°C
Svhc
No SVHC (15-Dec-2010)
Count Speed Max
20kHz
Preset counter electronical
T T e e c c h h n n i i c c a a l l d d a a t t a a
122
2 counting inputs
Gate
I I n n p p u u t t s s
T T y y p p e e 7 7 1 1 6 6 / / 7 7 1 1 7 7 a a n n d d 7 7 1 1 7 7 E E x x
Supply voltage:
Display:
Counting inputs:
Polarity of the inputs:
Input resistance:
Counting frequency:
Minimum pulse
duration for inputs:
Input switching level:
Pulse shape:
Output 1 Relay:
or npn optocoupler:
Output 2 Relay:
The maximum frequency is 20 kHz (20 kHz
in the phase discriminator mode); it can
be reduced to 30 Hz
Static gate input
pulse count mode: no counting, when the
input is active
timer mode: Counting when active gate.Io
or not activated Gate.hi programmable
www.kuebler.com
10 ... 30 V DC, max. 1,2 W with
reverse polarity protection
90 ... 260 V AC, max. 5 VA
6-digit red 7 segment LED; 8 mm high
2 counting inputs, 4 types of
programmable inputs
programmable, common for all inputs
appr. 10 kΩ
20 kHz, cab be reduced to 30 Hz
5 ms
DC version:
AC version:
any shape (Schmitt-Trigger)
with potential-free contacts, programmable as
normally-closed (NC) or normally-open (NO)
switching voltage max. 250 V AC/125 V DC,
switching current max. 3 A.
switching current min. at DC 30 mA
switching power max. DC 90 W
with open collector and emitter
switching power 30 V DC/15 mA
with potential free switching contact,
programmable opening or closing.
Low: 0 ... 0,2 x U B [V DC]
High: 0.6 x U B ... 30 V DC
Low 0 ... 4 V DC
High 12 ... 30 V DC
max. AC 750 VA
• very bright 8 mm high display
• programmable as a pulse counter, fre-
• Wide range Power supply
Y Y o o u u r r b b e e n n e e f f i i t t
Reset
Key
quency meter or an operating time
counter
90 ... 260 V AC or
10 ... 30 V DC
Dynamic reset input with the same func-
tion as the reset key. Resets the counter
to zero, when counting up and sets it to
the preset value when counting down
Static key lock input. The keys are locked
as long as this input is on. The
preselection display key remains active.
-proof version
approval
or npn-optocoupler:
Accuracy:
Output
response time:
Data storage:
Transmitter voltage:
Ambient temperature:
Storage temperature:
EMC:
EMC:
Protection:
Weight:
only for ex proof:
F F u u r r t t h h e e r r p p r r o o d d u u c c t t f f e e a a t t u u r r e e s s
• Display range –199 999 ... 999 999 with
• easy to use and programmable with
• Option: serial interface
• Relay or optocoupler output
• Scaling factor 0.0001 ... 99.9999
7 7 1 1 6 6 : : one preset
7 7 1 1 7 7 : : two presets
I I n n t t e e r r f f a a c c e e s s : :
zero blanking
only 4 keys
RS 232, RS 422, RS 485
switching voltage max. 250 V AC/300 V DC,
switching current max. 3 A.
switching current at DC min. 30 mA
switching power
with open collector an d emitter
switching power 30 V DC/15 mA
<0,1 % (at frequency meter mode)
±50 ppm (at time counter mode)
Relay: appr. 7 ms
Optocoupler: appr. 2 ms
min. 10 years or 10 6 memory cycles
24 V DC –40 %/+15 %, 100 mA
at AC version
–10 ... +50 °C
–25 ... +70 °C
according to EC EMC directive 89/36/EWG
EN 61 000-6-4/EN 55 011 class B
EN 61 000-6-2
IP65 (front) EX-proof IP54
appr. 200 g, Ex-execution 2 kg
Counter in EX proof version
acc. to explosion-proof class EEx D IIC T6,
with encapsulated cable 2 x 3 m
PTB approval no. Ex-96.D. 1024
hartcoated AL-housing
function mode as type 717
Note: the Ex-proof version has an
additional fuse.
The devices can be fitted with the option-
al RS 232, RS422 or with the RS 485 inter-
faces. These interfaces can be used to
program the devices as well as for
remote reading. They are simply
controlled by ESC sequences,
max. 4800 Baud
at DC 50 W
at AC max. 2000 VA
3/2005

Related parts for 6.716.010.000

6.716.010.000 Summary of contents

Page 1

Preset counter electronical ...

Page 2

Preset counter electronical The counters 716/717 are programmed by means of the 4 front keys. The operator guidance ...

Page 3

Preset counter electronical 717 ...

Page 4

Preset counter electronical ...

Related keywords