5406436-1 TE Connectivity, 5406436-1 Datasheet - Page 6

5406436-1

Manufacturer Part Number
5406436-1
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 5406436-1

Product Type
Connector
Jack Type
RJ45
Pcb Mounting Orientation
Top Entry (Vertical)
Pcb Mount Style
Through Hole
Termination Method To Pc Board
Solder
Performance Category
Cat 3
Number Of Contacts Loaded
8
Grounding Options
Panel Ground and PCB Ground
Panel Stops
With
Keyed
No
Profile
Standard
Color
Black
Shield Material
Copper Alloy
Latch Style
Standard
Jack Configuration
1 x 1
Panel Mount Retention
With
Flanged
No
Shielded
Yes
Solder Tail Contact Plating
Tin over Nickel
Height (mm [in])
16.64 [0.655]
Port Configuration
Single
Number Of Positions
8
Inverted Jack Face
No
Led
Without
Shield Plating
Tin
Number Of Pcb Ground Tabs
2
Pcb Tail Length (mm [in])
3.18 [0.125]
Pcb Ground Tab Location (mm [in])
2.95 [0.116]
Preloaded
Yes
Contact Plating, Mating Area, Material
Gold (50)
Contact Base Material
Phosphor Bronze
Housing Material
PBT - GF
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Pcb Thickness, Recommended (mm [in])
1.57 [0.062]
Packaging Method
Tray
4.
4.1.
4.2.
4.3.
4.4.
Rev G
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit, or function are made to the product or to the manufacturing
process, product assurance shall coordinate requalification testing, consisting of all or part of the
original testing sequence as determined by development/product, quality, and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup, or operator deficiencies shall not disqualify the product. When
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Testing to confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Sample Selection
Modular plug and jack test samples shall be selected at random from current production lots. They
shall be prepared for testing in accordance with current Application Specifications and Instruction
Sheets.
Test Sequence
Qualification testing shall be conducted as specified in Figure 2.
108-1163
6 of 7

Related parts for 5406436-1