B41692A8228Q007 EPCOS Inc, B41692A8228Q007 Datasheet - Page 12

Aluminum Electrolytic Capacitors - Leaded 2200UF 63V AL-ELKO AXIAL LEADED

B41692A8228Q007

Manufacturer Part Number
B41692A8228Q007
Description
Aluminum Electrolytic Capacitors - Leaded 2200UF 63V AL-ELKO AXIAL LEADED
Manufacturer
EPCOS Inc
Series
B41692r
Datasheet

Specifications of B41692A8228Q007

Capacitance
2200 uF
Tolerance
- 10 %, 30 %
Voltage Rating
63 Volts
Esr
38 mOhms
Operating Temperature Range
- 40 C to + 125 C
Termination Style
Axial
Dimensions
21 mm Dia. x 49 mm L
Product
General Purpose Electrolytic Capacitors
Load Life
5000 Hrs
Ripple Current
19.3 Amps
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B41692A8228Q007
Manufacturer:
TDK-EPCOS
Quantity:
30 000
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.