HAS 50-S LEM USA Inc, HAS 50-S Datasheet

SENSOR CURRENT 50A -/+15V MOD

HAS 50-S

Manufacturer Part Number
HAS 50-S
Description
SENSOR CURRENT 50A -/+15V MOD
Manufacturer
LEM USA Inc
Series
HASr
Datasheet

Specifications of HAS 50-S

Current - Sensing
50A
Accuracy
±1%
Sensitivity
-
Current - Supply
±15mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
-15 V ~ 15 V
Output
-
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-10°C ~ 80°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1049
Current Transducer HAS 50 .. 600-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
V
I
R
V
R
R
X
ε
V
V
TCV
TCV
t
di/dt
BW
T
T
m
090914/10
C
r
A
S
C
OUT
L
OE
OH
IS
OUT
L
Electrical data
Accuracy - Dynamic performance data
General data
OE
OUT
Supply voltage (± 5 %)
Current consumption
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ± I
Output internal resistance
Load resistance
Accuracy @ I
Linearity error
Electrical offset voltage, T
Hysteresis offset voltage @ I
Temperature coefficient of V
Temperature coefficient of V
Response time to 90 % of I
di/dt accurately followed
Frequency bandwidth (- 3 dB)
Ambient operating temperature
Ambient storage temperature
Mass
Standards
HAS 100-S
HAS 200-S
HAS 300-S
HAS 400-S
HAS 500-S
HAS 600-S
HAS 50-S
Type
5)
PN
3)
, T
(0 .. ± I
2)
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
A
= 25°C (excluding offset)
Primary nominal
PN
1)
current rms
after an excursion of 1 x I
)
A
PN
= 25°C
I
PN
OE
OUT
100
200
300
400
500
600
P
50
step
PN
(A)
=0,
4)
(% of reading)
, R
L
approx
HAS 50-S
HAS 100 .. 600-S < ± 1
approx
=10 kΩ, T
measuring range
Primary current,
A
= 25°C ± 4V ± 40
I
± 150
± 300
± 600
± 900
± 900
± 900
± 900
PM
(A)
PN
± 15
± 15
> 1000
100
> 1
< ± 1
< ± 1
< ± 20
< ± 20
< ± 2
< ± 0.1
< 3
> 50
DC .. 50
- 10 .. + 80
- 25 .. + 80
60
EN 50178: 1997
1)
RoHS since
date code
45217
45325
45166
45326
45333
45201
45260
% of I
mV/K
mV/K
A/µs
%/K
kHz
MΩ
mV
mV
mV
mA
kΩ
°C
°C
µs
%
PN
V
g
I
Features
Advantages
Applications
Application domain
PN
Hall effect measuring principle
Galvanic isolation between
primary and secondary circuit
Isolation voltage 3000 V
Low power consumption
Extended measuring range
(3 x I
Insulated plastic case made of
polycarbonate PBT recognized
according to UL 94-V0.
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
AC variable speed drives
Static converters for DC motor
drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Industrial.
= 50 .. 600 A
PN
)
www.lem.com
Page 1/3

Related parts for HAS 50-S

HAS 50-S Summary of contents

Page 1

... R =10 kΩ 25°C ± 4V ± approx 100 > 1 < ± 1 < ± 1 < ± 20 =0, P < ± HAS 50-S < ± 2 HAS 100 .. 600-S < ± reading) < ± 0.1 step < 3 > approx 60 EN 50178: 1997 600 A PN Features ● ...

Page 2

... Current Transducer HAS 50 .. 600-S Isolation characteristics V Rms voltage for AC isolation test, 50 Hz, 1 min d Impulse withstand voltage 1.2/50 µ dCp Creepage distance dCI Clearance distance CTI Comparative Tracking Index (group IIIa) Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ● ...

Page 3

... HAS 50 to 600-S Dimensions Dimensions HAS 50..600-S Dimensions HAS 50 .. 600-S 4 MOLEX 5045-04A Mechanical characteristic ● General tolerance PINS A RRANGEMENT 1 = +15V 2 = 15V 3 = OUTPUT Notes: Operating at ± ≤ V < ± will reduce the measuring range the customer uses 1 kΩ of the load resistor, the primary current has to be limited as the nominal. ...