CR9550-50 CR Magnetics Inc, CR9550-50 Datasheet

no-image

CR9550-50

Manufacturer Part Number
CR9550-50
Description
SENSOR CURRENT AC 5VDC .61 50AAC
Manufacturer
CR Magnetics Inc
Series
CR9500r
Datasheet

Specifications of CR9550-50

Current - Sensing
50A
Accuracy
±0.5%
Sensitivity
-
Current - Supply
-
Sensor Type
Current Sensor
Voltage - Supply
-
Output
0 ~ 5 VDC
Frequency
50Hz ~ 400Hz
Response Time
250ms
Polarization
Unidirectional
Operating Temperature
-30°C ~ 60°C
Package / Case
Ring, 0.61" Dia, Wire Leads
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
582-1032
Another HUNTINGTON ELECTRIC Company
1.775 (45)
1.614(41)
CR9521
CR9550
(MM)
0.875
(22.2)
IN
CR9550-10-M
CR9550-20-M
CR9550-50-M
CR9580-10-M
CR9580-20-M
CR9580-50-M
1.062
Part Number
(27)
CR9521-10
CR9521-20
CR9521-50
CR9550-10
CR9550-20
CR9550-50
CR9580-10
CR9580-20
CR9580-50
CR9521 and CR9550
OUTLINE DRAWING
0.27 (6.8) DIA. CR9521
0.61 (15.5) DIA. CR9550
+
-
AWG #22, 12 (304) LONG
PART NUMBER
0.875
(22.2)
CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
AC Current Range
36.86 mm
49.57 mm
1.95
1.45
10
20
50
10
20
50
10
20
50
10
20
50
10
20
50
CR9580
25.42 mm
1.00
0.40
10.17 mm
23.39 mm
0.92
24.91 mm
0.98
0.40
10.17 mm
50.84 mm
2.00
The CR9500 Series Current Sensors provides a cost effective
method for monitoring electrical current. The sensor generates a
0-5 VDC signal proportional to the input AC current. The output
signal is average sensing, calibrated to RMS.
The sensor is used with process control and industrial instrumen-
tation equipment. Especially suited for OEM applications that
require a low cost solution for numerous monitoring locations.
The DC output can be connected directly to an analog input
connection without additional signal conditioning. Care must be
taken to ensure the burden impedance of the instrumentation is
greater than 1.0 megohm. The unit will operate with lower bur-
den impedance but at reduced accuracy.
Applications
OEM Current Sensing
Home Automation
Monitor Motor Operation
Features
Low Cost
Low Fixed Trip Point
Fully Isolated, Reverse Polarity Protected
Self-Powered
Available in Mountable Package
Output Overload Protected
Specifications
Accuracy: ± .5% Full Scale (FS)
Ripple:
Signal Out: 0-5 VDC
Max. Signal Out: 12 VDC
Frequency * : 50 to 400 Hz
Insulation Class: 600 V
Operating Temperature: -30 C to + 60 C
Storage Temperature: -55 C to + 85 C
Shipping Weight: 2 oz. (.06 Kg.)
Dielectric Withstand: 2,500 Vrms
Response Time:
Calibration: Avg. Sensing, RMS Calibrated
Output Load: 1.0 Megohm or greater for rated accuracy
Weight 0.11 LBS.
* All specifications for operation at 60 Hz
Regulatory Agencies
79
1% Max
250 ms. max. 10-90% FS
E-mail: sales@crmagnetics.com
Current Sensor
E