G6SK-2F-HDC2POINT4 Omron, G6SK-2F-HDC2POINT4 Datasheet - Page 3

no-image

G6SK-2F-HDC2POINT4

Manufacturer Part Number
G6SK-2F-HDC2POINT4
Description
RELAY LOW SIGNAL LATCHING SMD
Manufacturer
Omron
Series
G6Sr

Specifications of G6SK-2F-HDC2POINT4

Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
58.3mA
Coil Voltage
2.4VDC
Turn On Voltage (max)
1.8 VDC
Turn Off Voltage (min)
-
Features
-
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
Silver (Ag), Gold (Au)
Operate Time
4ms
Release Time
4ms
Coil Power
140 mW
Coil Resistance
41 Ohms
Operating Temperature
-40°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6SK2FHDC2POINT4
Operation
■ Single-side Stable Relays
The contacts of this simple type of relay momentarily turn ON and
OFF, depending on the energized state of the coil.
■ Dual Coil, Latching Relays
This latching relay has two coils: set and reset. It can retain the ON
or OFF states even when a pulsating voltage is supplied, or when the
voltage is removed.
Contact Styles
Contact ratings are generally indicated according to resistive loads
and inductive loads (cosφ = 0.4 or L/R = 7 ms). Contact shape and
material are also shown to guide the customer in selection of a
model suitable for the intended load and required service life.
(Standard/Non-latching)
Mounting orientation mark
Mounting orientation mark
Terminal Arrangement/
Internal Connections
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
S: Set coil
R: Reset coil
Example
S R
0.001
0.01
0.1
1
Gold-clad
bifurcated
crossbar
contact
Electromechanical Relays
Gold-plated
single contact
■ Single Coil, Latching Relays
Unlike the dual coil latching relay, the single-winding latching relay
has only one coil. This coil, however, serves as both the set and reset
coils, depending on the polarity (direction) of current flow. When cur-
rent flows through the coil in the forward direction, it functions as a
set coil; when current flows through the coil in the reverse direction, it
functions as a reset coil.
■ Built-in Diode
A diode is built into some relays, wired in parallel with the coil to
absorb the counterelectromotive force (counter emf) generated by
the coil.
■ Built-in Operation Indicator
Some relays are provided with a light-emitting diode (LED), wired in
parallel with the coil. This permits a fast-check of the relay’s operat-
ing status.
When used at extremely low loads, the failure rate differs according
to the contact material and contact method, as shown in the figure.
For example, in comparing a single contact point with a bifurcated
contact point, the bifurcated contact model has higher parallel redun-
dancy and will therefore exhibit a lower failure rate.
Gold-plated
bifurcated
contact
10 VDC (constant)
Mounting orientation mark
Technical Information
Load current (mA)
Terminal Arrangement/
Internal Connections
(Bottom View)
S: Set coil
R: Reset coil
S R
3