Specifications of G6S-2G-10DC24

Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Non Latching
Coil Current
8.3mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Features
-
Mounting Type
Surface Mount
Termination Style
J Lead
Contact Material
Silver (Ag), Gold (Au)
Operate Time
4ms
Release Time
4ms
Coil Power
200 mW
Coil Resistance
2.88K Ohms
Operating Temperature
-40°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6S2G10DC24
Glossary
■ Terms Related to Contacts
Carry Current
The value of the current which can be continuously applied to the
relay contacts without opening or closing them, and which allows the
relay to stay within the permissible temperature rise.
Maximum Switching Current
A current which serves as a reference in determining the perfor-
mance of the relay contacts. This value will never exceed the current
flow. When using a relay, do not exceed this value.
Contact Form
OMRON uses the following relay terminology for the various polarity
and switch configurations.
1 FORM A: SPST-NO
1 FORM B: SPST-NC
1 FORM C: SPDT
2 FORM C: DPDT
Make-before-break (MBB) Contact
A contact arrangement in which part of the switching section is
shared between both an NO and NC contact. When the relay oper-
ates or releases, the contact that closes the circuit operates before
the contact that opens the circuit releases. Thus both contacts are
closed momentarily at the same time.
6
Contact symbols
Double-break
Make-before-break
NO
Electromechanical Relays
NC
Latching relays
NC
DT
Technical Information
Contact Resistance
The total resistance of the conductor, as well as specific resistivities
such as of the armature and terminal, and the resistance of the con-
tacts. Contact resistance values given in this catalog are initial val-
ues. These values are not intended to indicate suitability or
unsuitability in actual use. The contact resistance values given are
measurement values for a stable contact circuit at a stable contact
resistance. This value is determined by measuring the voltage drop
across the contacts by applying test currents as shown in the table
below.
For most applications, use at least 1 A, 5 VDC for contact resistance
measurements.
Maximum Switching Capacity
The maximum value of the load capacity which can be switched with-
out problem. When using a relay, do not exceed this value.
For example, when maximum switching voltage V
mum switching current I
on the characteristic curve “Maximum Switching Capacity” shown
below. Conversely, maximum switching voltage V
I
Under 0.01
0.01 to 0.1
0.1 to 1
Over 1
1
is known.
Maximum switching current (I
Maximum switching voltage (V
For instance, if the maximum switching voltage = 40 V
Maximum switching current = 2 A (see circled point on graph
below.)
Rated current (A)
1
can be obtained at the point of intersection
Switching voltage (V)
1
) =
1
) =
1
10
100
1000
Max. switching power [W(VA)]
Max. switching power [W(VA)]
Max. switching voltage (V1)
Max. switching current (I1)
Test current (mA)
1
can be obtained if
1
is known, maxi-

Related parts for G6S-2G-10DC24