BXRA-C0402-00E00 Bridgelux, BXRA-C0402-00E00 Datasheet

56T4712

BXRA-C0402-00E00

Manufacturer Part Number
BXRA-C0402-00E00
Description
56T4712
Manufacturer
Bridgelux
Series
Bridgelux ES Arrayr
Datasheet

Specifications of BXRA-C0402-00E00

Led Color
Cool White
Luminous Flux @ Test
450lm
Cct
5600K
Forward Current @ Test
500mA
Forward Current If Max
1A
Forward Voltage @ Test
9.5V
Viewing Angle
120°
Rohs Compliant
Yes
Bridgelux ES Array Series
BXRA Product Data Sheet DS11
Introduction
The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solid-
state lighting solutions to serve the general lighting market. These products combine the higher efficacy,
lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources.
The Bridgelux ES Array Series has been specified to enable lamp and luminaire designs surpassing
efficacy and quality of light requirements driven by regulatory standards with reasonable system design
margins, enabling lighting product compliance to Energy Star, Title 24, Part L and other global standards.
The Bridgelux ES Array products provide a high performance alternative to conventional solid state
solutions, delivering between 400 and 2000 lumens under application conditions in warm, neutral and
cool white color temperatures. These compact high flux density light sources deliver uniform high quality
illumination without pixilation or the multiple shadow effect caused by LED component based solutions.
To simplify system design for appropriate light output, Bridgelux LED Arrays are specified to deliver
performance under typical use conditions.
These integrated plug and play solutions reduce system complexity and enable miniaturized cost-
effective lamp and luminaire designs. Lighting system designs incorporating these LED Arrays deliver
comparable performance to that of 20-100 Watt incandescent and halogen, 7-42 Watt compact
fluorescent, and 18-50 Watt HID based luminaires and feature increased system level efficacy and
service life. Typical applications include replacement lamps, task, accent, spot, retail, track, down light,
low bay, wide area, security, wall pack and street lighting.
Features
1 0 1 P o rt o l a A v e n u e , L i v e rm o re , C A 9 4 5 5 1 • T e l : (9 2 5 ) 5 8 3 -8 4 0 0 • Fa x: (9 2 5 ) 5 8 3 -8 4 0 1 • ww w. b ri d g e l u x. c o m
Compact high flux density light source
Uniform high quality illumination
Streamlined thermal path
Energy Star / ANSI compliant binning
structure
More energy efficient than incandescent,
halogen and fluorescent lamps
Low voltage DC operation
Instant light with unlimited dimming
Five-year warranty
RoHS compliant and Pb free
Benefits
Enhanced optical control
Clean white light without pixilation
Significantly reduced thermal resistance
and increased operating temperatures
Uniform consistent white light
Lower operating costs
Increased safety
Easy to use with daylight and motion
detectors to enable increased energy
savings
Reduced maintenance costs
Environmentally friendly, no disposal issues

Related parts for BXRA-C0402-00E00

BXRA-C0402-00E00 Summary of contents

Page 1

... Bridgelux ES Array Series BXRA Product Data Sheet DS11 Introduction The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solid- state lighting solutions to serve the general lighting market. These products combine the higher efficacy, lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources. ...

Page 2

... Typical Chromaticity Characteristics vs. Temperature Typical Forward Current Characteristics 25° C Current Derating Curves Product Binning Luminous Flux Binning Information Color Binning Information Mechanical Assembly and Handling Product Packaging and Labeling Packaging Tube Design Design Resources Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Page ...

Page 3

... D E – designates product family – used to designate product options, 00000 by default The base product part number (BXRA-ABCDE) is indicated on each individual unit, printed on the bottom of the LED Array. Average Lumen Maintenance Characteristics Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current ...

Page 4

... Class 2 Driver to facilitate the UL listing process. Minor Product Change Policy The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Cautionary Statements CAUTION: CONTACT WITH OPTICAL AREA Contact with the resin area should be avoided ...

Page 5

... Case Temperature Measurement Point A case temperature measurement point location is included on the top surface of the Bridgelux LED Arrays. The location of this measurement point is indicated in the mechanical dimensions section of this data sheet. The purpose of this measurement point is to allow the user access to a measurement point closely linked to the true case temperature on the back surface of the LED Array ...

Page 6

... BXRA-W0403 Warm White BXRA-W0802 BXRA-W1202 BXRA-W1203 BXRA-N0402 Neutral White BXRA-N0802 BXRA-N1203 BXRA-C0402 BXRA-C0603 Cool White BXRA-C0802 BXRA-C1202 BXRA-C2002 Notes for Table 1: 1. Bridgelux maintains a ± 7% tolerance of flux measurements. 2. Parts are tested in pulsed conditions Pulse width rated test current. 3. Typical performance when driven with direct current using Bridgelux test set-up. Please contact a Bridgelux sales representative for additional details ...

Page 7

... Warm White BXRA-W0802 BXRA-W1202 BXRA-W1203 BXRA-N0402 Neutral BXRA-N0802 White BXRA-N1203 BXRA-C0402 BXRA-C0603 Cool BXRA-C0802 White BXRA-C1202 BXRA-C2002 Notes for Table 2: 1. Parts are tested in pulsed conditions Pulse width rated test current. 2. Refer to Flux Characteristic Table for test current data. 3. Product is binned for color coordinates. ...

Page 8

... BXRA-W0802 11.2 BXRA-W1202 13.9 BXRA-W1203 17.3 BXRA-N0402 Neutral BXRA-N0802 11.2 White BXRA-N1203 17.3 BXRA-C0402 BXRA-C0603 25.8 Cool BXRA-C0802 11.7 White BXRA-C1202 11.8 BXRA-C2002 14.9 Notes for Table 3: 1. Parts are tested in pulsed conditions Pulse width rated test current. 2. Bridgelux maintains a tester tolerance of ± 0. forward voltage measurements. ...

Page 9

... BXRA-W0802 2000 BXRA-W1202 2500 BXRA-W1203 2000 BXRA-N0402 1500 BXRA-N0802 2000 BXRA-N1203 2000 BXRA-C0402 1000 BXRA-C0603 500 BXRA-C0802 1500 BXRA-C1202 2000 BXRA-C2002 2500 Notes for Table 4: 1. Light emitting diodes are not designed to be driven in reverse voltage. 2. Driving these high current devices at low currents can result in variations in performance. For low current operation pulse width modulation is recommended ...

Page 10

... BXRA-W0401 BXRA-W0402 BXRA-W0403 Warm White BXRA-W0802 BXRA-W1202 BXRA-W1203 Notes for Table 6: 1. Product is tested and binned at the specified drive current. 2. Operating these LED Arrays at or below the drive currents listed in Table 6, with a case temperature maintained at or below 70° C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet ...

Page 11

... Part Number BXRA-N0402 BXRA-N0802 Neutral White BXRA-N1203 Notes for Table 7: 1. Product is tested and binned at the specified drive current. 2. Operating these LED Arrays at or below the drive currents listed in Table 7, with a case temperature maintained at or below 70° C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet ...

Page 12

... BXRA-C0603 BXRA-C0802 Cool White BXRA-C1202 BXRA-C2002 Notes for Table 8: 1. Product is tested and binned at the specified drive current. 2. Operating these LED Arrays at or below the drive currents listed in Table 8, with a case temperature maintained at or below 70° C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet ...

Page 13

... Mechanical Dimensions Figure 1: Drawing for 400 lumen product options (part numbers BXRA-C0402, BXRA-N0402, BXRA-W0401, BXRA-W0403, BXRA-W0402 and BXRA-C0603). Notes for Figure 1: 1. Slots are for M2 screws. 2. Solder pads are labeled “+” and “-“ to denote positive and negative, respectively. 3. Drawings are not to scale. ...

Page 14

... Mechanical Dimensions (continued) Figure 2: Drawing for 800, 1200, and 2000 lumen product options (part numbers BXRA-C0802, BXRA- W0802, BXRA-C1202, BXRA-W1202, BXRA-W1203, BXRA-N0802, BXRA-N1203 and BXRA- C2002). Notes for Figure 2: 1. Mounting holes are for M2 screws. 2. Solder pads are labeled “+” and “-“ to denote positive and negative, respectively. ...

Page 15

... Typical Radiation Pattern Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Figure 3: Typical Spatial Radiation Pattern Figure 4: Typical Polar Radiation Pattern Page ...

Page 16

... Wavelength Characteristics at Rated Test Current, Tj=25° C Figure 5: Typical Warm White Color Spectrum Figure 6: Typical Neutral White Color Spectrum Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Page ...

Page 17

... Wavelength Characteristics at Rated Test Current, T Figure 7: Typical Cool White Color Spectrum Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) =25° C (continued) j Page ...

Page 18

... Typical Relative Luminous Flux vs. Current, Tj=25° C Figure 8: Typical Flux vs. Current (400lm arrays) Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Figure 9: Typical Flux vs. Current Page ...

Page 19

... Typical Relative Luminous Flux vs. Current, T Figure 10: Typical Flux vs. Current (800 lm Arrays) Figure 11: Typical Flux vs. Current (1200 lm Arrays) Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) =25° C (continued) j Page ...

Page 20

... Typical Relative Luminous Flux vs. Current, T Figure 12: Typical Flux vs. Current (2000 lm Arrays) Note for Figures 8 through 12: Bridgelux does not recommend driving high power LED Arrays at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) =25° ...

Page 21

... Typical Light Output Characteristics vs. Temperature Figure 11: Typical Flux vs. Junction Temperature Figure 13: Typical Flux vs. Junction Temperature 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 -10 0 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11 Junction Temperature, ºC Cool White Warm White Neutral White Page ...

Page 22

... Figure 13: Typical y Shift vs. Junction Temperature Figure 15: Typical y Shift vs. Junction Temperature 0.02 0.01 0.00 -0.01 -0.02 -0.03 -0.04 -0.05 -0.06 -10 0 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11 Junction Temperature, º Junction Temperature, ºC Cool White Neutral White Warm White 50 60 ...

Page 23

... Typical Forward Current Characteristics 25° C Figure 16: Typical Current vs. Voltage, BXRA-C0402 Figure 17: Typical Current vs. Voltage, BXRA-N0402 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Forward Voltage Forward Voltage Page ...

Page 24

... Typical Forward Current Characteristics at T Figure 18: Typical Current vs. Voltage, BXRA-W0401 Figure 19: Typical Current vs. Voltage, BXRA-W0402 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) = 25° C (continued) j Forward Voltage Forward Voltage Page ...

Page 25

... Typical Forward Current Characteristics at T Figure 20: Typical Current vs. Voltage, BXRA-W0403 and BXRA-C0603 Figure 21: Typical Current vs. Voltage, BXRA-C0802 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) = 25° C (continued) j Forward Voltage Forward Voltage Page ...

Page 26

... Typical Forward Current Characteristics at T Figure 22: Typical Current vs. Voltage, BXRA-N0802 and BXRA-W0802 Figure 23: Typical Current vs. Voltage, BXRA-C1202 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) = 25° C (continued) j Forward Voltage Forward Voltage Page ...

Page 27

... Figure 24: Typical Current vs. Voltage, BXRA-N1203, BXRA-W1203 Figure 25: Typical Current vs. Voltage, BXRA-W1202 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Forward Voltage Forward Voltage Page ...

Page 28

... Typical Forward Current Characteristics at T Figure 26: Typical Current vs. Voltage, BXRA-C2002 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) = 25° C (continued) j Forward Voltage Page ...

Page 29

... Figures 27-37 are total system values (junction to ambient) including the thermal resistance of the LED Array. Individual LED Array thermal resistance values are listed in Table 3. Figure 27: Derating Curve for BXRA-W0403 and BXRA-C0603, 250mA Drive Current Figure 28: Derating Curve for BXRA-C0402, 500mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 10.0˚ ...

Page 30

... Current Derating Curves (continued) Figure 29: Derating Curve for BXRA-N0402, 600mA Drive Current Figure 30: Derating Curve for BXRA-W0401, 700mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 8.0˚C/W 6.0˚C/W 4.0˚C/W 6.0˚C/W 4.0˚C/W 3.0˚C/W Page ...

Page 31

... Current Derating Curves (continued) Figure 31: Derating Curve for BXRA-W0402, 700mA Drive Current Figure 32: Derating Curve for BXRA-C0802, 700mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 6.0˚C/W 4.0˚C/W 3.0˚C/W 5.0˚C/W 3.0˚C/W 2.0˚C/W Page ...

Page 32

... Current Derating Curves (continued) Figure 33: Derating Curve for BXRA-W0802, BXRA-N0802, 1050mA Drive Current Figure 34: Derating Curve for BXRA-C1202, 1050 mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 4.0˚C/W 3.0˚C/W 1.5˚C/W 4.0˚C/W 3.0˚C/W 1.5˚C/W ...

Page 33

... Current Derating Curves (continued) Figure 35: Derating Curve for BXRA-N1203 and BXRA-W1203, 1050 mA Drive Current Figure 36: Derating Curve for BXRA-W1202, 1200 mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 2.0˚C/W 1.5˚C/W 1.0˚C/W 2.0˚C/W 1.5˚C/W 1.0˚C/W ...

Page 34

... Current Derating Curves (continued) Figure 37: Derating Curve for BXRA-C2002, 1500 mA Drive Current Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) 2.0˚C/W 1.5˚C/W 1.0˚C/W Ta – Ambient Temperature °C Page ...

Page 35

... In order to minimize variation in the end product or application, Bridgelux bins its LED Arrays for luminous flux and color. Bridgelux LED Arrays are labeled using a 4-digit alphanumeric bin code. This bin code is printed on the back of each LED Array in the following format: ...

Page 36

... Table 10: Warm White xy Bin Coordinates and Associated Typical CCT Bin X Code 0.3943 0.3996 N3 0.4148 0.4083 0.3889 0.3943 N4 0.4083 0.4018 0.4083 P3 0.4148 0.4299 0.4223 0.4018 0.4083 P4 0.4223 0.4147 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11 ...

Page 37

... J3 0.3642 0.3617 0.3512 0.3530 J4 0.3617 0.3591 0.3617 0.3642 K3 0.3736 0.3703 0.3591 0.3617 K4 0.3703 0.3670 Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) ANSI Y CCT Bin X (K) 0.3601 0.3703 0.3736 0.3736 4500 L3 0.3805 0.3871 0.3663 0.3828 0.3465 0.3670 0.3601 0.3703 ...

Page 38

... Figure 40: Graph of Cool White Test Bins in xy Color Space 0.38 0.38 0.37 0.37 0.36 0.36 0.35 0.35 0.34 0.34 0.33 0. 0.32 0. 0.31 0.31 0.30 0.30 0.31 0.31 Table 12: Cool White xy Bin Coordinates and Associated Typical CCT Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11 0.32 0.32 0.33 0.33 0.34 0. ...

Page 39

... Bridgelux recommends the use of hard non-electrically conductive flat washers with lock washers. Refer to Application Note AN11 – Handling and Assembly of Bridgelux LED Arrays, for more details. ...

Page 40

... Product Packaging and Labeling All Bridgelux LED Array products are 100% tested, binned and labeled. Products are labeled by printing pertinent information on the back side of the array. The following format is used for labeling the Bridgelux LED Arrays – – Where – designates the bin code (LQ30, etc – ...

Page 41

... Product Packaging and Labeling (continued) Tubes of Bridgelux LED Arrays are packaged in bags prior to loading into boxes for shipment. One tube is loaded per bag, resulting in an SPI of 25 for hexagonal star products and 20 for rectangular product configurations. All products packaged within a single bag are of the same flux and color bin combination (or bin code) ...

Page 42

... – designates the bin code (LQ30, etc – designates the date code (production week and production year, 0210, etc – designates the quantity per listed bin code contained in the box. Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Figure 45: Box Label Example Page ...

Page 43

... Packaging Tube Design Figure 46: Tube Design for Hexagonal Star Products Figure 47: Tube Design for Rectangular Array Products Notes for Figures 46 and 47: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. Bridgelux ES Array Series Product Data Sheet DS11 (04/04/11) Page ...

Page 44

... Optical Source Models Optical source models and ray set files are available for all Bridgelux LED Array products, and can be downloaded directly from the Bridgelux web site. The list below contains the formats currently available. If you require a specific format not included in this list, please contact your Bridgelux sales representative for assistance ...

Page 45

... The plug and play simplicity of the Bridgelux LED Arrays enable our customers to address the rapidly growing interior and exterior solid state lighting markets, including street lights, retail lighting, commercial lighting and consumer applications ...