AT49LV001N-70TI Atmel, AT49LV001N-70TI Datasheet - Page 6

no-image

AT49LV001N-70TI

Manufacturer Part Number
AT49LV001N-70TI
Description
Manufacturer
Atmel
Datasheet

Specifications of AT49LV001N-70TI

Cell Type
NOR
Density
1Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
17b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP-I
Program/erase Volt (typ)
3 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
128K
Supply Current
25mA
Mounting
Surface Mount
Pin Count
32
Lead Free Status / Rohs Status
Not Compliant
Command Definition (in Hex)
Notes:
Absolute Maximum Ratings*
6
Command
Sequence
Read
Chip Erase
Sector Erase
Byte Program
Boot Block Lockout
Product ID Entry
Product ID Exit
Product ID Exit
Temperature Under Bias................................ -55°C to +125°C
Storage Temperature ..................................... -65°C to +150°C
All Input Voltages
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to V
Voltage on OE
with Respect to Ground ...................................-0.6V to +13.5V
1. The DATA FORMAT in each bus cycle is as follows: I/O7 - I/O0 (Hex)
2. The 16K byte boot sector has the address range 00000H to 03FFFH for the AT49BV/LV001(N) and
3. Either one of the Product ID Exit commands can be used.
4. SA = sector addresses:
AT49BV/LV001(N)(T)
1C000H to 1FFFFH for the AT49BV/LV001(N)T.
For the AT49BV/LV001(N):
SA = 00000 to 03FFF for BOOT BLOCK
Nothing will happen and the device goes back to the read mode in 100 ns
SA = 04000 to 05FFF for PARAMETER BLOCK 1
SA = 06000 to 07FFF for PARAMETER BLOCK 2
SA = 08000 to 0FFFF for MAIN MEMORY ARRAY BLOCK 1
This command will erase - PB1, PB2 and MMB1
SA = 10000 to 1FFFF for MAIN MEMORY ARRAY BLOCK 2
For the AT49BV/LV001(N)T:
SA = 1C000 to 1FFFF for BOOT BLOCK
Nothing will happen and the device goes back to the read mode in 100 ns
SA = 1A000 to 1BFFF for PARAMETER BLOCK 1
SA = 18000 to 19FFF for PARAMETER BLOCK 2
SA = 10000 to 17FFF for MAIN MEMORY ARRAY BLOCK 1
This command will erase - PB1, PB2 and MMB1
SA = 00000 to 0FFFF for MAIN MEMORY ARRAY BLOCK 2
(3)
(3)
(2)
Cycles
Bus
1
6
6
4
6
3
3
1
XXXX
Addr
5555
5555
5555
5555
5555
5555
Addr
1st Bus
Cycle
Data
D
AA
AA
AA
AA
AA
AA
F0
OUT
(1)
CC
2AAA
2AAA
2AAA
2AAA
2AAA
2AAA
Addr
2nd Bus
+ 0.6V
Cycle
Data
55
55
55
55
55
55
*NOTICE:
Addr
5555
5555
5555
5555
5555
5555
3rd Bus
Cycle
Data
80
80
A0
80
90
F0
Stresses beyond those listed under “Absolute Maxi-
mum Ratings” may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other condi-
tions beyond those indicated in the operational sec-
tions of this specification is not implied. Exposure to
absolute maximum rating conditions for extended
periods may affect device reliability.
Addr
5555
5555
5555
Addr
4th Bus
Cycle
Data
AA
D
AA
AA
IN
2AAA
2AAA
2AAA
Addr
5th Bus
Cycle
Data
55
55
55
1110C–FLASH–9/03
Addr
5555
SA
5555
6th Bus
(4)
Cycle
Data
10
30
40

Related parts for AT49LV001N-70TI