Specifications of G6E134PSTUSDC12

Relay Construction
Non-Latching
Contact Arrangement
SPDT
Coil Voltage Dc
12V
Coil Current
16.7mA
Contact Form
1 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
1.2VDCV
Coil Resistance
720Ohm
Pick-up Voltage (max)
8.4VDC
Maximum Power Rating
60W/50VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
8.38mm
Product Depth (mm)
9.91mm
Product Length (mm)
16mm
Operating Temp Range
-40C to 70C
Pin Count
5
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant
Subminiature, Sensitive Signal Relay
• Subminiature 7.87 H x 9.91 W x 16 L mm.
• High sensitivity with pick-up coil power of 98 mW.
• Surge withstand voltage meets FCC Part 68 requirements.
• Unique moving loop armature reduces relay size, magnetic
• Bifurcated crossbar contact assures high reliability.
• Single and Dual coil latching versions available.
• Fully sealed construction.
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6E-134P-ST-US-DC6).
Model Number Legend
Specifications
■ Contact Data
Note: P level:
SPDT
2. Contact Form
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note) 10 ?A, 10 mVDC
1. Relay Function
interference, and contact bounce time.
Low Signal Relay
G6E
G6E
1:
None: Single-side stable
U:
K:
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
1
Double-winding latching
Single-winding latching
SPDT
-
λ
2 3 4 5 6
60
= 0.1 x 10
Contact form
Bifurcated crossbar
–6
/operation
0.40 A at 125 VAC, 2 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
3 A
50 VA, 60 W
-
7
-
4. Enclosure Ratings
3. Contact Type
8
3: Bifurcated crossbar
4: Fully sealed
DC
Ag (Au-Alloy) contact
Resistive load (p.f. = 1)
Straight
Self-clinching
9
Terminal style
5. Terminals
6. Special Function
G6E-134P-US
G6E-134C-US
P: Straight PCB
C: Curved tail
L: Low sensitivity coil (400 mW)
Standard
0.20 A at 125 VAC, 1 A at 30 VDC
25 VA, 30 W
Model
Inductive load (p.f. = 0.4) (L/R = 7 ms)
Low Signal Relay
G6EU-134P-US
G6EU-134C-US
Single coil latching
9. Rated Coil Voltage
7. Standoff dimension
8. Approved Standards
Blank: 0.3 mm
ST:
US: UL, CSA certified
3, 5, 6, 9, 12, 24, 48 VDC
G6E
G6EK-134P-US
G6EK-134C-US
Dual coil latching
0.64 mm
R
C
89

Related parts for G6E134PSTUSDC12

G6E134PSTUSDC12 Summary of contents

Page 1

Low Signal Relay G6E Subminiature, Sensitive Signal Relay • Subminiature 7. 9. mm. • High sensitivity with pick-up coil power of 98 mW. • Surge withstand voltage meets FCC Part 68 requirements. • Unique ...

Page 2

Coil Data Standard Non-latching Type (G6E-134P(-ST)-US, G6E-134C(-ST)-US) Rated Rated Coil voltage current resistance (VDC) (mA) (Ω) 3 66. 125 6 33.30 180 9 22.20 405 12 16.70 720 24 8.30 2,880 48 8.30 5,760 Low-sensitivity Non-latching ...

Page 3

Low-sensitivity Dual Coil Latching Type (G6EK-134PL(-ST)-US) Rated Rated Coil voltage current resistance (VDC) (mA) (Ω) 3 133 22.50 5 79. 66. 44.30 203 12 33.30 360 24 16.70 1,440 Note: 1. The rated current and coil ...

Page 4

Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Standard coil G6E-134P(L)(-ST)-US 0.6 1.6 G6E-134C(-ST)-US 3.16 2.86 0.6 1.6 Single coil latching G6EU-134P(L)(-ST)-US 0.6 1.6 G6EU-134C(-ST)-US 2.86 3.16 0.6 1.6 G6E ...

Page 5

Dual coil latching G6EK-134P(L)(-ST)-US 0.6 1.6 G6EK-134C(-ST)-US 2.86 3.16 0.6 1.6 ■ Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928 Ambient Temp. = 40°C Contact form Coil ratings SPDT VDC Note: ...

Page 6

... The relay is reset by the discharge current of C flowing in the relay via transistor TR and C. Note: 1. Give adequate consideration to the circuit constant when actually using this circuit, confirming the set and reset status of the relay. 2. OMRON owns the patent on this circuit. Consult OMRON when using this circuit. G6E 94 Low Signal Relay Wiring Refer to the following diagram when wiring to switch a DC load ...

Page 7

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 8

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords