MAX9598CTL+T Maxim Integrated Products, MAX9598CTL+T Datasheet - Page 21

IC SWITCH DUAL SCART 40TQFN

MAX9598CTL+T

Manufacturer Part Number
MAX9598CTL+T
Description
IC SWITCH DUAL SCART 40TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX9598CTL+T

Function
Switch
Circuit
2 x SCART
On-state Resistance
7 Ohm
Voltage Supply Source
Single, Dual Supply
Voltage - Supply, Single/dual (±)
3 V ~ 3.6 V, ±11.4 V ~ 12.6 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
40-WFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 4. Register Settings for Looping VCR Signals to the TV
Note 5: TV slow-switch output (bits 1 and 0) should be the same as VCR slow-switch input.
Note 6: User has to set bits 7 and 3 appropriately depending upon whether signal is red or chroma.
All circuitry is shut down in the MAX9598 except for the
I
Except for register 10h, which sets the operating mode,
the values in all the other I
while entering, during, and leaving shutdown mode.
Put the MAX9598 into low-power mode during standby.
Everything is shut down except for the slow-switching
circuits, CVBS input detection, CVBS load detection,
and I
active low whenever the slow-switch signal changes; a
CVBS signal appears or disappears; or a CVBS load
appears or disappears. The µC in the set-top box can
then decide whether to change the MAX9598 to full-
power mode and loop VCR signals to the TV.
Before entering low-power mode, the slow-switch sig-
nals should be set to high impedance.
Except for registers 0Eh, 0Fh, and 10h, the value in all of
the other I
ing, and leaving low-power mode. The values in registers
Table 5. Quiescent Power Consumption
2
Loop VCR signals to the
TV
Shutdown.
Low-power mode with slow switching, CVBS input video
detection, and video load detection active only. Audio circuitry
is off.
Full-power mode WITH input video detection and video load
detection active.
Full-power mode WITHOUT input video detection and video
load detection active (power-on default).
C interface, which is designed with static CMOS logic.
2
DESCRIPTION
C interface. If interrupt is enabled, then INT will go
2
C registers are preserved while entering, dur-
______________________________________________________________________________________
OPERATING MODE
REGISTER
2
C registers are preserved
00h
01h
06h
07h
08h
09h
0Dh
10h
Low-Power Audio/Video Switch for
Low-Power Mode
7
0
0
0
0
0
1
x
Shutdown
6
0
0
0
0
0
0
0
5
0
0
0
0
0
1
0
Dual SCART Connectors
4
Default
1
0
1
0
0
1
0
BIT
0Eh and 0Fh might change in low-power mode because
they provide status on the slow switch signals, CVBS
input, and CVBS outputs. The value in register 10h
changes while entering or leaving low-power mode
because bits 6 and 7 set the operating mode.
In this mode, the MAX9598 is fully on. If interrupt is
enabled, then INT will go active low whenever the slow-
switch signal changes; a CVBS signal appears or dis-
appears; or a CVBS load appears or disappears. The
µC can decide whether to change the routing configu-
ration or operating mode of the MAX9598.
This mode is similar to the above mode except that
video input detection and video load detection are not
active. If interrupt is enabled, then INT will go active low
only when the slow-switch signal changes.
3
1
1
0
0
1
0
x
Full-Power Mode Without Video Input Detection
2
1
0
0
1
1
1
0
Full-Power Mode with Video Input Detection
POWER CONSUMPTION (mW)
1
0
1
1
1
1
0
x
0
1
0
0
1
0
x
1
(Note 5)
(Note 6)
0.1
1.7
71
70
and Video Load Detection
and Video Load Detection
COMMENTS
21

Related parts for MAX9598CTL+T