ZIB-PDX-N NANOTEC, ZIB-PDX-N Datasheet

no-image

ZIB-PDX-N

Manufacturer Part Number
ZIB-PDX-N
Description
58T5289
Manufacturer
NANOTEC
Datasheet

Specifications of ZIB-PDX-N

Accessory Type
Interface Board
Rohs Compliant
Yes
For Use With
PD6-N Motors
Accessories
g
g
Operating voltage:
Interface:
Temperature range:
Nanotec Electronic GmbH & Co.KG – Gewerbestr. 11 – D-85652 Landsham – Tel.: 0049 (0) 89-900686-0 – Fax.: 0049 (0) 89-900686-50 – info@nanotec.de
Connection of voltage supply (X4)
The voltage supply must be ensured via 2 connectors each:
Pin 6, 11: 24-48V
Pin 10, 15: Power GND
Communication
Optionally communication can be made via a CAN bus (connector X6) or an RS485 bus (con-
nector X5). The connection is only possible via the converter cable ZK-RS485-USB.
Inputs/Outputs
All inputs and outputs are made available via the X4 connector.
!
Technical data
Information on the application
PD-I (X4)
Caution: Only suitable for support during commissioning and test operation.
Additional board ZIB-PDx-N for PDx-N Plug & Drive motors
Pin
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
Function
Input 5
Input 4
Input 3
Input 2
Input 1
+UB24-48V
Input 6
Output 3
Signal GND
Power GND
+UB24-48V
Analog Input
Output 2
Output 1
Power GND
X3
X2
X1
DC 24 to 48 V
RS485 or CANopen
0 to + 40 °C
RS-485 (X5)
Pin
1
2
3
4
5
6
7
8
9
Function
NC
RX+
NC
TX+
NC
NC
RX-
GND
TX-
X4
X5
X6
PDx-N Data 1 (X1)
PDx-N Data 2 (X2)
PDx-N supply (X3)
CANopen (X6)
WH/GN
GY/BN
WH/PK
RD/BU
BN/GN
WH/BU
WH/YE
WH/GY
GY/PK
YE/BN
Pin
WH
Pin
GY
PK
YE
GN
BN
BU
RD
BK
VT
Pin
Pin
1
2
1
2
3
4
5
6
7
8
9
Function
RS485 TX+
RS485 TX-
RS485 RX-
RS485 RX+
CAN+
CAN-
Signal GND
GND
GND
+UB external
Function
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Analog Input
Output 1
Output 2
Output 3
Function
+UB
Power GND
Function
NC
CAN-
GND
NC
NC
GND
CAN+
NC
+UB_Ext
g
NANOTEC produces component parts that are deployed in a variety of industrial applications. The selection and
application of NANOTEC products is the responsibility of the system constructor or end user. NANOTEC accepts no
responsibility for the integration of the products in the end system.
Under no circumstances may a NANOTEC product be integrated as the sole safety control in a product or construc-
tion. All positioning controls without exception must be designed so that errors are detected dynamically and fail-
safe under all circumstances. All products which contain a component part manufactured by NANOTEC must show
appropriate warning notices and instructions for a safe application and safe operation on delivery to the end user. All
warning notices provided by NANOTEC must be immediately passed on to the end user.
NANOTEC only accepts an express warranty for the quality of its own products in agreement with the standards and
specifications as they appear in the NANOTEC manual. ALL OTHER IMPLICIT and EXPLICIT WARRANTIES ARE
EXCLUDED. NANOTEC assumes no liability for injuries, product damage, loss or claims that arise through incorrect
application of the products.
Safety instructions
The symbols used in this manual are defined in the following in order to grade the safety instructions and to identify
the degree of danger associated with it. Non compliance with the precautionary measures specified in this manual
can lead to grave or even fatal injury, and/or personal damage, damage to products, facilities and systems.
CAUTION
Indicates a potentially dangerous situation that can lead to mortal or severe injury if they are not avoided.
ATTENTION
Indicates a potentially dangerous situation that can lead to minor or fairly serious injury if it is not avoided.
The product is checked on delivery, installation, wiring, maintenance, inspection and during operation on the basis
of following safety instructions.
Installation
ATTENTION
Do not use the products in environments where they are exposed to water, corrosive gases, inflammable
gases or fuels.
Otherwise there is a danger of electric shock or fire.
Only use the ZIB printed circuit board for tests during the commissioning. It is not designed for permanent
operation.
Wiring
ATTENTION
Make sure that the polarity of the power supply is correct. Otherwise the drive used can be damaged.
Make sure that the wires mounted on the connector are correctly seated. Otherwise there is a danger of short-
circuit or fire.
Quick Start Guide
Operation
ATTENTION
Never touch rotating parts of the motor while the motor is running. Otherwise there is a danger of injury.
Never touch the ZIB printed circuit board when the voltage supply applied. Otherwise there is a danger of injury.
Do not touch any of the motors during operation. Otherwise the high temperatures can cause panic reactions.
Maintenance and inspection
ATTENTION
Do not attempt to disconnect the plug connectors or cable while the voltage is switched on. There is a danger
of electric shock.
After switching off the voltage supply wait until the back-up capacitors have discharged. There is a danger of
electric shock from the residual voltage.
The ZIB printed circuit board is maintenance-free.
General safety instructions
PAY ATTENTION TO THE FOLLOWING INSTRUCTIONS TO ENSURE SAFE APPLICATION:
Some figures in this manual show the product with the protective covers or shielding removed. Always replace the
protective cover or shielding as stated before putting the product into operation according to the specifications in
the manual.
The figures in this manual are used as typical examples and can vary from your actual product.
The manual is subject to change as a result of product improvements, changes to the specifications and revision of
the manual. If revisions are made to the manual, the version number is updated and the new manual is issued as a
new edition.
If you would like to reorder a manual because of loss or damage, you can download it free of charge from the
homepage at www.nanotec.de. If it is not available, please contact NANOTEC directly.
NANOTEC accepts no responsibility for results that arise from unauthorized changes to the product. NANOTEC
assumes no liability for damage or failures that are caused by unauthorized changes.

Related parts for ZIB-PDX-N