V15W11-EZ200-W3 Honeywell Sensing and Control, V15W11-EZ200-W3 Datasheet

no-image

V15W11-EZ200-W3

Manufacturer Part Number
V15W11-EZ200-W3
Description
SWITCH SNAP SPDT 10A 125V
Manufacturer
Honeywell Sensing and Control
Series
V15Wr

Specifications of V15W11-EZ200-W3

Mfg Application Notes
Watertight Switches Transportation Applications
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187" (4.7mm)
Operating Force
200gf
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
480-3752
Installation Instructions for the
MICRO SWITCH™ V-Basic Standard V15W
Watertight Switches
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
Failure to comply with these instructions could result
in death or serious injury.
GENERAL INFORMATION
MICRO SWITCH™ V-Basic Standard V15W Watertight
switches are precision snap-action contact mechanisms
enclosed in watertight plastic cases. Switch actuation
triggers the mechanical closure of the switch’s contacts.
A small amount of arcing between the contacts during
contact closure occurs during normal operation. In order
to obtain desired switch performance, the switch must be
chosen based on the mechanical, electrical and
environmental conditions of the application.
Do not use this product in water. Although molded lead
wire versions carry an ingress protection rating of IP67
according to the test conditions of IEC 529, this test is to
check the ingress of water into the switch enclosure after
submerging the switch in water for a given time.
Sensing and Control
CAUTION
SWITCH DAMAGE
• Wiring must be rated to meet or exceed circuitry
• Connecting circuitry must not exceed switch rating.
• Wiring connections must be properly secured.
• Do not exceed recommended soldering time or
• Do not contact switch housing with soldering device.
• Do not exceed recommended mounting screw tightening
• Discontinue use if switch has been damaged or cover
• Do not apply side loads to actuator or exceed specified
• Do not operate or store in areas where corrosive gases
Failure to comply with these instructions may result
in product and/or property damage.
IMPROPER USE
Failure to comply with these instructions will result in
death or serious injury.
• Do not use in hazardous environments where
requirements.
temperature.
torques.
removed.
travel limits.
such as hydrogen sulfide are present.
stop devices or in any other application where failure of
the product could result in personal injury.
flammable or explosive gases or liquids such as
gasoline or thinners, etc., are present.
WARNING
Satisfying this test condition does not mean that the
switch can be used in water. Switches with terminals are
also sealed, but because the terminals are exposed the
corresponding degree of protection is IP00.
MOUNTING INFORMATION
*To prevent loosening of screws, use spring washers
• Turn OFF the power supply before mounting or removing
• Mount the switch onto a flat surface. Mounting on an
• Use an operating device with low frictional resistance
• Position the operating device perpendicular to the
• Position the operating device so that no force is applied
• The operating device should be positioned so that when
• The operating device should never force the
WIRING INFORMATION – TERMINAL VERSIONS
• Connect wires firmly to terminals.
• Replace wires that have damaged insulation.
• Use properly sized spade terminals.
• Use wire rated for the application’s electrical load and
• Provide strain relief when a potential exists for forces to
under screw heads and thread lock adhesive.
Mounting
hole size
3,1 mm
2,9 mm
(-K option)
the switch, wiring, or performing maintenance or
inspection. Failure to do so may result in electric shock.
uneven surface may cause deformation of the switch,
resulting in faulty operation or damage.
and of a shape that will not interfere with the plunger seal
otherwise the plunger may be damaged or the sealing
may deteriorate.
actuator/pushbutton to prevent side loading of the switch
actuator or pushbutton.
to the pushbutton/actuator when the switch is in the free
position.
the switch is in the operating position it should move the
actuator no less than 70% of the total travel. Setting the
travel position so that less than 70% of the total travel is
used may cause poor contact or welding conditions due
to an insufficient contact switching force.
actuator/pushbutton to exceed the total travel position.
application’s temperature
be transferred from the lead wires to the switch terminals
Flat fillister
Screw
Type*
Flat fillister
head
head
Screw
Size
3 mm
#4
50066512
Tightening
Torque (max.)
5,8 kg-cm
[5.0 in-lb]
5,8 kg-cm
[5.0 in-lb]
ISSUE 1

Related parts for V15W11-EZ200-W3

V15W11-EZ200-W3 Summary of contents

Page 1

... Sensing and Control 50066512 Satisfying this test condition does not mean that the switch can be used in water. Switches with terminals are also sealed, but because the terminals are exposed the corresponding degree of protection is IP00. MOUNTING INFORMATION ...

Page 2

... MICRO SWITCH™ V-Basic Standard V15W Watertight Switches • The switch is sealed around the terminals. However, live terminals should never be exposed to water. Use appropriate sealed connectors or mount the switch in a sealed enclosure so that the terminals are not exposed to water. WIRING INFORMATION - PRE-LEADED VERSIONS • ...