SI3215-C-FT Silicon Laboratories Inc, SI3215-C-FT Datasheet - Page 95

no-image

SI3215-C-FT

Manufacturer Part Number
SI3215-C-FT
Description
IC SLIC/CODEC 1CH 38TSSOP
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheet

Specifications of SI3215-C-FT

Package / Case
*
Function
Subscriber Line Interface Concept (SLIC), CODEC
Interface
PCM, SPI
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 5.25 V
Current - Supply
88mA
Power (watts)
700mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
Audio Tone Generation, BORSCHT Functions, FSK Generation, Voice Loopback Test Modes
Product
SLIC
Supply Voltage (min)
3.13 V
Supply Current
88 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Number Of Channels
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register 96. Calibration Control/Status Register 1
Reset settings = 0001_1111
Name
Type
Bit
Bit
7
6
5
4
3
2
1
0
Reserved
CALSP
Name
CALIL
CALR
CALD
CALC
CALT
D7
CAL
CAL
R/W
D6
Read returns zero.
Calibration Control/Status Bit.
Setting this bit begins calibration of the entire system.
0 = Normal operation or calibration complete.
1 = Calibration in progress.
Calibration Speedup.
Setting this bit shortens the time allotted for V
calibration cycle.
0 = 300 ms
1 = 30 ms
RING Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
TIP Gain Mismatch Calibration.
For use with discrete solution only. When using the Si3201, consult “AN35: Si321x
User’s Quick Reference Guide” and follow instructions for manual calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Differential DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Common Mode DAC Gain Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
I
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
LIM
Calibration.
CALSP
R/W
D5
CALR
R/W
D4
Rev. 0.92
CALT
R/W
D3
Function
CALD
R/W
BAT
D2
settling at the beginning of the
CALC
R/W
D1
CALIL
R/W
D0
Si3215
95

Related parts for SI3215-C-FT