54489-6 TE Connectivity, 54489-6 Datasheet - Page 3

Power to the Board HSG WITH FLANGES 6P

54489-6

Manufacturer Part Number
54489-6
Description
Power to the Board HSG WITH FLANGES 6P
Manufacturer
TE Connectivity
Series
Series Ir
Datasheets

Specifications of 54489-6

Product Type
Plug Housings
Contact Gender
Pin (Male), Socket (Female)
Voltage Rating
600 VAC
Number Of Positions / Contacts
6
Mounting Style
In Line
Housing Material
Nylon
Connector Type
Housing
Pcb Mount Retention
With
Sealed
No
Ul File Number
E28476
Csa File Number
LR7189
Wire/cable Type
Discrete Wire
Mating Retention Type
Lock
Profile Height (y-axis) (mm [in])
7.92 [0.312]
Number Of Positions
6
Centerline (mm [in])
7.92 [0.312]
Mating Retention
With
Length (x-axis) (mm [in])
24.51 [0.965]
Width (z-axis) (mm [in])
60.25 [2.372]
Number Of Rows
1
Housing Color
Natural
Connector Style
Plug - Receptacle
Mating Alignment
With
Mating Alignment Type
Polarization
Custom Configurable
No
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Vde Tested
No
Agency/standard
UL, CSA
Ul Rating
Recognized
Csa Certified
Yes
Applies To
Panel, Wire/Cable
Application Use
Wire-to-Panel, Wire-to-Wire
Contact Transmits (typical Application)
Power
Packaging Method
Loose Piece
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
54489-6
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
31 584
Rev B
Physical shock.
Durability.
Contact retention.
Mating force.
Unm ating force.
Therm al shock.
Hum idity-tem perature cycling.
Tem perature life.
Mixed flowing gas.
NOTE
Test Description
Shall meet visual requirements, show no physical damage and shall meet requirements of
additional tests as specified in Test Sequence in Figure 2.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
10 pounds m axim um per contact
pair.
1.75 pounds m inim um per contact
pair.
See Note.
See Note.
See Note.
See Note.
W ire Size
( AW G)
18
16
14
12
ENVIRONMENTAL
Figure 1 (end)
Requirem ent
Retention Force
(Lbs m axim um )
10
15
20
20
TE Spec 109-26-2.
Subject m ated sam ples to 75 G's
half-sine shock pulses of 6
m illiseconds duration. 3 shocks in
each direction applied along 3
m utually perpendicular planes, 18
total shocks.
TE Spec 109-27.
Mate and unm ate sam ples for 20
cycles at m axim um rate of 600
cycles per hour.
TE Spec 109-30.
Apply axial load to contacts by
gripping wire and hold for 10
seconds.
TE Spec 109-42, Condition A.
Measure force necessary to m ate
sam ples at m axim um rate of .5 inch
per m inute.
TE Spec 109-42, Condition A.
Measure force necessary to
unm ate sam ples at m axim um rate
of .5 inch per m inute.
TE Spec 109-22.
Subject m ated sam ples to 5 cycles
between -55 and 85°C.
TE Spec 109-23-3,
Condition B.
Subject m ated sam ples to 10
cycles between 25 and 65°C at
95% RH.
TE Spec 109-43.
Subject m ated sam ples to
tem perature life at 85°C for 1000
hours.
TE Spec 109-85-2.
Subject m ated sam ples to
environm ental class II for 14 days.
Procedure
108-11026
3 of 9