1393277-8 TE Connectivity, 1393277-8 Datasheet

no-image

1393277-8

Manufacturer Part Number
1393277-8
Description
Manufacturer
TE Connectivity
Type
Power Relayr
Datasheet

Specifications of 1393277-8

Relay Construction
Non-Latching
Contact Arrangement
SPDT
Coil Voltage Dc
24V
Coil Current
66.29mA
Contact Form
1 Form C
Dropout Volt (min)
2.4VDCV
Coil Resistance
362Ohm
Pick-up Voltage (max)
14.1VDC
Operate Time
5ms
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Depth (mm)
21.5mm
Product Length (mm)
26.5mm
Operating Temp Range
-40C to 105C
Pin Count
7
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant
n
n
n
n
Typical applications
ABS control, blower fans, car alarm, cooling fan, engine control, fuel pump,
hazard warning signal, heated front screen, heated rear screen, ignition,
lamps front/rear/fog light, interior lights, main switch/supply relay, seat
control, seatbelt pretensioner, sun roof, turn signal, valves, window lifter,
wiper control.
06-2011, Rev. 0611
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Contact Data
Typical applications
Contact arrangement
Rated voltage
Rated current
Limiting continuous current
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Initial voltage drop, at 10A, typ./max.
Operate/release time
Electrical endurance
Mechanical endurance, DC coil
1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC or 27VDC for 24VDC load voltages.
2) For a load current duration of maximum 3s for a make/break ratio of 1:10.
3) Corresponds to a peak inrush current on initial actuation (cold filament).
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/
5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher
Max. DC load breaking capacity
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
Limiting continuous current 45A
Wide voltage range
24VDC coil versions available
For high current version refer to Power Relay K-S
23°C
85°C
risk of contact tack welding.
1)
2)
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Resistive/inductive
at 13.5VDC, 40A
1 form A, 1 NO
>2x10
AgNi0.15
12VDC
loads
100A
45A
45A
30A
60A
5
ops.
Automotive Relays
PCB Single Relays
Power Relay K (Open – Sealed)
Resistive/inductive
at 13.5VDC, 40A
1 form C, 1 CO
A/B (NO/NC)
>2x10
TE0556-E
AgNi0.15
100/30A
45/30A
45/30A
30/25A
60/30A
12VDC
loads
5
ops.
1A at 5VDC
typ. 5/3ms
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
20/300mV
>10
7
ops.
Indicator lamps
1 form A, 1 NO
5)
>2.2x10
4)
up to 8x21W
AgSnO
12VDC
120A
30A
30A
25A
60A
6
3)
ops.
2
capacitive loads
1 form A, 1 NO
up to 4x60W
Headlights,
>10
AgSnO
12VDC
180A
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
40A
40A
25A
60A
5
ops.
2
capacitive loads
1 form C, 1 CO
A/B (NO/NC)
up to 4x60W
Headlights
>10
180/60A
AgSnO
12VDC
40/25A
40/25A
25/20A
60/30A
5
ops.
2
1

Related parts for 1393277-8

1393277-8 Summary of contents

Page 1

... Rev. 0611 Datasheets and product specification ac- www.te.com cording to IEC 61810-1 and to be used only © 2011 Tyco Electronics Corporation, together with the ‘Definitions’ section Connectivity Ltd. company. Automotive Relays PCB Single Relays Power Relay K (Open – Sealed) Resistive/inductive loads ...

Page 2

... Rev. 0611 Datasheets and product specification ac- www.te.com cording to IEC 61810-1 and to be used only © 2011 Tyco Electronics Corporation, together with the ‘Definitions’ section Connectivity Ltd. company. Automotive Relays PCB Single Relays Power Relay K (Open – Sealed) Insulation Data 12VDC / 24VDC ...

Page 3

... Datasheets and product specification ac- www.te.com cording to IEC 61810-1 and to be used only © 2011 Tyco Electronics Corporation, together with the ‘Definitions’ section Connectivity Ltd. company. Automotive Relays PCB Single Relays Power Relay K (Open – Sealed) Power Relay K sealed version 23.3 ±0.7 9.2 ± ...

Page 4

... AgSnO 2 AgNi0.15 1 form A, NO AgSnO 2 AgSnO special 2 Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change 1393277-4 1393277-6 1-1393277-4 1-1393277-7 1-1414175-0 1393277-8 1393277-9 1-1393277-8 1-1393277-9 1393278-7 1-1393278-3 5-1393278-7 5-1393278-9 1-1414173-0 3-1393278-7 3-1393278-9 7-1393278-1 7-1393278-2 1-1414174-0 ...

Related keywords