RM75TC-2H MITSUBISHI, RM75TC-2H Datasheet

no-image

RM75TC-2H

Manufacturer Part Number
RM75TC-2H
Description
150A - transistor module for medium power general use, insulated type
Manufacturer
MITSUBISHI
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RM75TC-2H
Manufacturer:
MITSUBISHI
Quantity:
63
Part Number:
RM75TC-2H
Manufacturer:
SEMIKRON
Quantity:
387
Part Number:
RM75TC-2H
Manufacturer:
MITSUBISHI/三菱
Quantity:
20 000
Part Number:
RM75TC-2H
Quantity:
60
APPLICATION
AC motor controllers, DC motor controllers, Battery DC power supplies,
DC power supplies for control panels, and other general DC power equipment
RM75TC-M,-H,-24,-2H
OUTLINE DRAWING & CIRCUIT DIAGRAM
5–M6
14
16
P
23
14
30
50
74
23
16
N
14
RM75TC-M,-H,-24,-2H
4– 4.5
• I
• V
• 3 phase bridge
• Insulated Type
• UL Recognized
O
RRM
Yellow Card No. E80276 (N)
DC output current .................... 150A
Repetitive peak reverse voltage
N
P
MEDIUM POWER GENERAL USE
MITSUBISHI DIODE MODULES
.......... 400/800/1200/1600V
File No. E80271
INSULATED TYPE
Dimensions in mm
Feb.1999

Related parts for RM75TC-2H

RM75TC-2H Summary of contents

Page 1

... DC power supplies for control panels, and other general DC power equipment OUTLINE DRAWING & CIRCUIT DIAGRAM 5– MITSUBISHI DIODE MODULES RM75TC-M,-H,-24,-2H MEDIUM POWER GENERAL USE • output current .................... 150A O • V Repetitive peak reverse voltage RRM .......... 400/800/1200/1600V • 3 phase bridge • Insulated Type • UL Recognized Yellow Card No ...

Page 2

... Voltage class M H 400 800 480 960 110 220 Conditions = Test conditions =150 C, V applied RRM = =150A, instantaneous meas. FM MITSUBISHI DIODE MODULES RM75TC-M,-H,-24,-2H MEDIUM POWER GENERAL USE INSULATED TYPE Unit 24 2H 1200 1600 V 1350 1700 V 370 440 V Ratings Unit 150 A 1500 ...

Page 3

... MAXIMUM POWER DISSIPATION 400 RESISTIVE, INDUCTIVE LOAD 350 300 250 200 150 100 50 0 – 160 MITSUBISHI DIODE MODULES RM75TC-M,-H,-24,-2H MEDIUM POWER GENERAL USE INSULATED TYPE FORWARD CURRENT 100 CONDUCTION TIME (CYCLES AT 60Hz 100 120 140 160 DC OUTPUT CURRENT (A) Feb.1999 ...