UHE-12/2500-D48 Datel, Inc., UHE-12/2500-D48 Datasheet

no-image

UHE-12/2500-D48

Manufacturer Part Number
UHE-12/2500-D48
Description
DC/DC Power Converters
Manufacturer
Datel, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UHE-12/2500-D48
Manufacturer:
COSEL
Quantity:
334
DATEL, Inc., Mansfi eld, MA 02048 (USA) • Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • Email: sales@datel.com • Internet: www.datel.com
Wide-Input-Range
"Q" Models
Features
!
!
!
!
!
!
!
!
!
!
!
The most I
Lower priced than bricks
Small 1.6" x 2" x 0.4" plastic package
with standard 2" x 2" pinout
Output confi gurations:
Five input ranges from 9-75 Volts
Effi ciencies as high as 91.5%
Stable no-load operation
Optional Sense pins for low V
Thermal shutdown, I/O protected
1500 Vdc I/O BASIC Insulation
UL/EN60950 certifi ed; CE marked
NEW
1.2/1.5/1.8/2.5V
3.3/5V
5/12/15V
CONTROL
ON/OFF
+INPUT
–INPUT
(4)
OUT
(1)
(2)
OUT
OUT
@ 25 Watts
/P
@ 30 Watts
OUT
OUT
in this format
@ 10 Amps
OUT
UVLO & OVLO
COMPARATORS
standard 2" x 2" pinout, DATEL's new UHE Series DC/DC Converters deliver more
current/power (up to 10A/30W) than currently available from either package size.
The UHE 12-30W Series of high-effi ciency, isolated DC/DC's provide output power
ranging from 10 Amps @ 1.2V to 2 Amps @ 15V. Offering both 2:1 and 4:1 input
voltage ranges, UHE's meet V
outstanding effi ciency (some models exceed 91%) enabling full-power operation to
ambient temperatures as high as +60°C, without air fl ow. Assembled using fully
automated, SMT-on-pcb techniques, UHE's provide stable no-load operation, excel-
lent line (±0.1%) and load (±0.15%) regulation, quick step response (200µsec), and
low output ripple/noise (50-100mVp-p). Additionally, the UHE's unique output design
eliminates one of the topology's few shortcomings–output reverse conduction.
voltage shutdown, precise output overvoltage protection (a rarity on low-voltage
outputs), output current limiting, short-circuit protection, and thermal shutdown.
(positive or negative polarity). Low-voltage models (1.2V to 5V) offer optional sense
pins facilitating either remote load regulation or current sharing for true N+1 redun-
dancy. All models are certifi ed to the BASIC insulation requirements of UL/EN60950,
and 48V
Housed in smaller, 1.6" x 2" x 0.40" (41 x 51 x 10.2mm) packages carrying the
Taking full advantage of the synchronous-rectifi er, forward topology, UHE's boast
All devices feature full I/O fault protection including: input overvoltage and under-
All UHE models incorporate a V
Figure 1. Simplifi ed Schematic
IN
CONTROLLER
SHUTDOWN
THERMAL
(75V max.) models carry the CE mark.
PWM
CONTROL
SWITCH
➀ Optional comparator feedback. Contact DATEL.
➁ Sense pins are optional on 1.2-5V
ISOLATION
2-10 Amp, 12-30 Watt DC/DC's
ISOLATION
OPTO
OPTO
IN
requirements from 9 to 75 Volts.
OUT
OVERVOLTAGE
COMPARATOR
Trim function and an On/Off Control pin
High Effi ciency, 1.6" x 2"
REFERENCE &
ERROR AMP
Single Output
OUT
models ("R" suffi x).
®
INNOVATION and EX C ELL E N C E
UHE Models
+OUTPUT
+SENSE
–SENSE
V
–OUTPUT
OUT
(5)
(8)
(6)
(9)
(7)
TRIM
®

Related parts for UHE-12/2500-D48

UHE-12/2500-D48 Summary of contents

Page 1

... Amp, 12-30 Watt DC/DC's Housed in smaller, 1.6" x 2" x 0.40" ( 10.2mm) packages carrying the standard 2" x 2" pinout, DATEL's new UHE Series DC/DC Converters deliver more current/power (up to 10A/30W) than currently available from either package size. The UHE 12-30W Series of high-effi ciency, isolated DC/DC's provide output power ranging from 10 Amps @ 1 ...

Page 2

... UHE-5/5000-Q48 5 5 UHE-5/6000-D48 5 6 UHE-12/2500-Q12 12 2.5 UHE-12/2500-D12 12 2.5 UHE-12/2500-D24 12 2.5 UHE-12/2500-Q48 12 2.5 UHE-12/2500-D48 12 2.5 UHE-15/2000-D12 15 2 UHE-15/2000-D24 15 2 UHE-15/2000-Q48 15 2 UHE-15/2000-D48 15 2 ➀ Typical +25°C under nominal line voltage and full-load conditions, unless noted. A ➁ Ripple/Noise (R/N) is tested/specifi ed over a 20MHz bandwidth. All models are specifi ed with an external 0.47µ ...

Page 3

... Contact DATEL for demonstrated life-test data. All models are fully operational and meet all published specifi cations, including "cold start," (10) at –40°C. 3 UHE Models Output Magnetic feedback 1.5-2.1 Volts 1.8-2.4 Volts 2.2-2.8 Volts 2.8 to 3.2 Volts ...

Page 4

... OUT Input Overvoltage Shutdown All D12/Q12 and D24 Models of the UHE DC/DC converters are equipped with Input Overvoltage Protection. Input voltages exceeding the input over- voltage shutdown specifi cation listed in the Performance/Functional Specifi - cations will cause the device to shutdown. A built-in hysteresis for all models will not allow the converter to restart until the input voltage is suffi ...

Page 5

... I/O Filtering, Input Ripple Current, and Output Noise All models in the UHE 12-30 Watt DC/DC Converters are tested/specifi ed for input refl ected ripple current and output noise using the specifi ed external input/output components/circuits and layout as shown in the following two fi ...

Page 6

... Trimming Output Voltage UHE converters have a trim capability (pin 9) that allows users to adjust the output voltages ± accomplished via a trim pot (Figure single fi xed resistor as shown in Figures 7 and 8. A single fi xed resistor can increase or decrease the output voltage depending on its connection. The resistor should be located close to the converter and have a TCR less than 100ppm/° ...

Page 7

... Use of trim and sense functions can cause output voltages to increase thereby increasing output power 5.58 –15.52 beyond the UHE’s specifi ed rating or cause output voltages to climb into the V – output overvoltage region. Therefore, the designer must ensure: ...

Page 8

... 24V 36V Output Current (Amps) UHE-1.5/10000-D48 Efficiency vs. Load @ + 36V 48V 75V Output Current (Amps Ambient UHE-1.8/10000-D24 Efficiency vs. Load @ +25 ° Ambient UHE-1.8/10000-D48 Efficiency vs. Load @ +25 ° Ambient ° 18V 24V 36V Output Current (Amps) C Ambient ° 36V 48V 75V Output Current (Amps ...

Page 9

... V = 75V IN 40 0.75 1.5 2.25 3 3.75 4.5 Output Current (Amps) C Ambient UHE-5/5000-Q12 Efficiency vs. Load @ +25 ° 5.25 6 6.75 7.5 0.5 1.0 C Ambient UHE-5/5000-Q48 Efficiency vs. Load @ +25 ˚ 100 5.25 6 6.75 7.5 0 Ambient UHE-5/6000-D48 Efficiency vs. Load @ +25 ˚ 100 0.6 1.2 5.25 6 6.75 7.5 9 UHE Models C Ambient ° ...

Page 10

... Output Current (Amps) UHE-12/2500-D24 Efficiency vs. Load @ + 24V 36V IN 65 0.25 0.5 0.75 1 1.25 1.5 Output Current (Amps) UHE-12/2500-D48 Efficiency vs. Load @ + 48V 75V IN 65 0.25 0.5 0.75 1 1.25 1.5 Output Current (Amps ° C Ambient UHE-15/2000-D12 Efficiency vs. Load @ + ...

Page 11

... UHE-12-2500-Q48 Efficiency vs. Load @ + 75V 0.25 0.5 0.75 1 1.25 1.5 Output Current (Amps) UHE-1.2/10000-D24 and UHE-1.5/10000-D24 Temperature Derating 10 9 24V STILL AIR IN, 8 24V , 150LFM IN 7 24V , 300LFM – Ambient Temperature (°C) UHE-1.2/10000-D48 and UHE-1.5/10000-D48 Temperature Derating 10 9 48V STILL AIR IN, ...

Page 12

... IN, 20 36V STILL AIR IN, 15 75V , 150LFM IN 75V , 300LFM – Ambient Temperature (°C) UHE-12/2500 and UHE-15/2000 (All Models) Temperature Derating 30 12V , STILL AIR IN 25 24V STILL AIR IN, (48V , Still Air for Q48 Models Only 48V STILL AIR IN, (D48 Models Only – ...

Page 13

... Current in mA OPTIONS AND ADAPTATIONS Optional Functions and Part Number Suffi xes The versatile UHE, 12-30W DC/DC converters offer numerous electrical and mechanical options. Per the Ordering Guide on page 2, the trailing DXX or QXX (where XX stands for 12 48V ) in each part number pertains IN to the base part number. Part-number suffi ...