MI-J22-IZ Vicor Corporation, MI-J22-IZ Datasheet - Page 4

no-image

MI-J22-IZ

Manufacturer Part Number
MI-J22-IZ
Description
Manufacturer
Vicor Corporation
Datasheet
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
CONVERTER SPECIFICATIONS (cont.)
[a]
Parameter
Storage temperature
Operating temperature (baseplate)
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures
Warranty
Environmental compliance
Derating
Parameter
Altitude
Explosive Atmosphere
Vibration
Shock
Acceleration
Humidity
Solder Test
Fungus
Salt-Fog
Test data available for review or download from vicorpower.com
PRODUCT GRADE SPECIFICATIONS
ENVIRONMENTAL QUALIFICATIONS
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./ min. to 70,000 ft., unit functioning
MIL-STD-810C, Method 511.1, Procedure I
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g
3 hrs /axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/octave, 7.7 G rms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
MIL-STD-202, Method 208, 8 hr. aging
MIL-STD-810C, Method 508.1
MIL-STD-810C, Method 509.1
Set your site on VICOR at www.vicorpower.com
[a]
NAVMAT P-4855-1A
12 hours, 29 cycles
-55°C to +125°C
-40°C to +100°C
-65°C to +100°C
-40°C, +80°C
MIL-STD-810
12 cycles
I-Grade
2 years
MI-J00 DC-DC Converters 10 to 50 Watts
2
/Hz, 2000 Hz @ 0.002 g
96 hours, 213 cycles
NAVMAT P-4855-1A
2
-65°C to +125°C
-55°C to +100°C
-65°C to +100°C
/ Hz, 3.9 total G rms
-55°C, +80°C
MIL-STD-810
12 cycles
M-Grade
2 years
Rev. 1.0
Page 4 of 6