OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (1 Cycle) [Apk]
Max. Off-State Leakage Current @ Rated Voltage [mA]
Maximum I 2 t for Fusing (8.3 msec) [A 2 sec]
Maximum Voltage Drop (100% On) [Vpk]
Minimum Off-State dv/dt [V/µsec]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
1
TYPICAL APPLICATIONS
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
SERIES PCV.
Rev. 012908
PAGE 1 OF 3
All parameters at 25º C unless otherwise specified.
Industrial Temperature Controllers
Light Dimming
Vibratory Feeders
Resistive Heating Elements
Conveyor Speed Control
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
Zero Crossing Applications
M O D E L N U M B E R S
• Operates at 60Hz & 50Hz
• Internal Snubber
• Industry Standard Package
• Control Circuit Requires No
Adjustment or Calibration
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
10PCV2415
7PCV2415
100-240
.15-15
600
150
200
1.6
0.5
10
94
7PCV24xx
2-7 Vdc
100
80
60
40
20
4 mA
0
10PCV2425
7PCV2425
100-240
.15-25
260
600
250
200
1.6
0.5
15
© 2008 CRYDOM Inc., Specifications subject to change without notice.
2.0
Percentage On vs. Input Voltage
3.0
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
10PCV2450
100-240
Analog Input Power Controller
4.0
.15-50
1620
600
625
200
1.6
0.5
20
Typical Curves
Input Voltage [Vdc]
Series
5.0
6.0
10PCV2475
100-240
.15-75
1000
4150
600
200
7.0
1.6
0.5
10PCV24xx
20
2-10 Vdc
4 mA
8.0
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
PCV
10PCV2490
9.0
100-240
.15-90
1200
6000
600
200
1.6
0.5
20
10.0

Related parts for 10PCV2450

10PCV2450 Summary of contents

Page 1

... The PCV Series proportional controllers are self contained power control mod- ules integrating a complete phase fired logic control system and a solid state relay in the same standard package. Typical applications include heaters, vibratory feeders and tungsten lamps. 10PCV2450 10PCV2475 10PCV2490 100-240 100-240 .15-50 .15-75 ...

Page 2

WIRING DIAGRAM ~ 1 OUTPUT 2 PROPORTIONAL CONTROLLER 4 3 INPUT -- + CURRENT DERATING CURVES 50A 60 .5°C/W 1°C/W 1.5°C/W 40 2°C HEATSINK Load Current [Arms] Max Ambient ...

Page 3

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO HAZARD OF RIESGO DE ELECTRIC DESCARGA SHOCK, ELECTRICA O EXPLOSION, EXPLOSION. OR ARC FLASH. • Desconectar • Disconnect all todos los power before suministros de installing or energia a este ...

Page 4

ANNEX – ENVIRONMENTAL INFORMATION: The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. ...

Related keywords