IRKT91/12 Ruttonsha, IRKT91/12 Datasheet
IRKT91/12
Available stocks
Related parts for IRKT91/12
IRKT91/12 Summary of contents
Page 1
... Ruttonsha International Rectifier Ltd. RUTTONSHA IRK.26, .41, .56, .71, .91 SERIES High Voltage Thyristor/Diode and Thyristor/Thyristor FEATURES Y Electrically isolated base plate. Y 3500 V isolating voltage. RMS Y Simplified mechanical designs, rapid assembly. Y Auxiliary cathode terminals for wiring convenience. Y High surge capability. Y Wide choice of circuit configurations. ...
Page 2
ELECTRICAL SPECIFICATION VOLTAGE RATINGS V Voltage Type Number Code 04 IRK.26/41/56/71/ ON-STATE CONDUCTION Parameter I Max.average on-state current(Thyristors) T(AV) I Max.average forward current (Diodes) F(AV) I Max. continuous RMS on-state current O(RMS) I Max. ...
Page 3
ELECTRICAL SPECIFICATION TRIGGERING Parameter P Max. peak gate power GM P Max. average gate power G(AV) I Max. peak gate current GM -V Max. peak negative gate voltage GM V Max. gate voltage required to trigger GT I Max. gate ...
Page 4
POWER MODULES IRK.26, .41, .56, .71, .91 SERIES OUTLINE DIAGRAM IRKT IRKH IRKL 4 ...
Page 5
POWER MODULES 130 IRK.26.. Series R (DC) = 0.62 K/W thJC 120 110 Conduction Angle 100 30° 60° 90° 120° 180° Average On-state Current (A) Fig Current Ratings Characteristics ...
Page 6
POWER MODULES 50 180° 120° 90° 40 60° 30° 30 RMS Conduction Angle IRK.26.. Series 10 Per Junction T = 125° Average On-state Current (A) 400 At Any ...
Page 7
POWER MODULES 250 200 180° 150 ( 180° (Rect) 100 2 x IRK.26.. Series 50 Single Phase Bri d ge Connected T = 125° Total Output Current (A) 350 ...
Page 8
POWER MODULES 1 Steady State Value 0.62 K/W thJC (DC Operation) 0.1 0.01 0.001 0.01 0.1 Square Wave Pulse Duration (s) 100 Rectangular gate pulse a)Recommended load line for rated di/dt ohms tr = 0.5 ...
Page 9
POWER MODULES 130 IRK.41.. Series R (DC) = 0.46 K/W thJC 120 110 Conduction Angle 100 30° 60° 90° 120° 90 180° Average On-state Current (A) Fig Current Ratings Characteristics IRK.41, ...
Page 10
POWER MODULES 70 180° 60 120° 90° 50 RMS Limit 60° 30° Conduction Angle 20 IRK.41.. Series 10 Per Junction T = 125° Average On-state Current (A) Fig. 15- On-state Power ...
Page 11
POWER MODULES 350 300 250 180° ( 200 180° (Rect) 150 100 2 x IRK.41.. Series Phase Bri d ge Connected 125° Total Output ...
Page 12
POWER MODULES 90 180° 80 120° 90° 70 60° 30° RMS Conduction Angle 20 IRK.56.. Series Per Juncti 125° ...
Page 13
POWER MODULES 450 400 350 180° 300 (Sine) 180° 250 (Rect) 200 150 2 x IRK.56.. Series 100 Phase Bridge Connected 125° 100 120 140 Total ...
Page 14
POWER MODULES 500 IRK.41.. Seri e s IRK.56.. Seri 200 A 450 125 °C J 400 100 A 350 50 A 300 250 20 A 200 10 A 150 100 ...
Page 15
POWER MODULES 130 IRK.71.. Series R (DC) = 0.33 K/W thJC 120 110 Conduction Angl e 100 90 30° 60° 90° 120° 80 180° Average On-state Current (A) Fig. 37- ...
Page 16
POWER MODULES 120 180° 120° 100 90° 60° 30° 80 RMS Limi Conduction Angle IRK.71.. Series 20 Per Junction T = 125° Average On-state Current (A) ...
Page 17
POWER MODULES 600 180° 500 (Sine) 180° (Rect) 400 300 200 2 x IRK.71.. Series Single Phase Bridge 100 Connected T = 125° 100 120 140 160 180 Total Output Current (A) Fig. ...
Page 18
POWER MODULES 140 180° 120° 120 90° 60° 100 30° RMS Limi Conduction Angle 40 IRK.91.. Series Per Junction 125° Average On-state Current (A) Fig ...
Page 19
POWER MODULES 600 180° ( 500 180° (Rect) 400 300 200 2 x IRK.91.. Series Single Phase Bridge 100 Connected T = 125° 120 Total Output Current (A) Fig On-state Power ...
Page 20
POWER MODULES 700 IRK.71.. Series I = 200 A TM IRK.91.. Series 600 T = 125 °C J 100 A 500 50 A 400 20 A 300 10 A 200 100 ...