Page 111
112
Page 112
113
Page 113
114
Page 114
115
Page 115
116
Page 116
117
Page 117
118
Page 118
119
Page 119
120
Page 120
121
122
123
124
125
126
127
128
Page 111/128

Download datasheet (2Mb)Embed
PrevNext
7HFKQRORJLHV ,QF
Offset 47 –Hardware Monitor Fan Configuration ......... RW
7-6
Fan 2 RPM Control
00 Divide by 1
01 Divide by 2 ............................................default
10 Divide by 4
11 Divide by 8
5-4
Fan 1 RPM Control
00 Divide by 1
01 Divide by 2 ............................................default
10 Divide by 4
11 Divide by 8
3-0
Reserved
........................................ always reads 0
Offset 49 –Hardware Monitor Temp Low Order Value RW
7-6
TSENS3 Value Low-Order Bits
Upper 8 bits are stored in offset 1Fh
5-4
TSENS2 Value Low-Order Bits
Upper 8 bits are stored in offset 21h
3
Over Temperature Active Low for PMU to
Control Stop Clock
0
Disable ...................................................default
1
Enable
2
Chassis Active Low Output 20 msec
0
Disable ...................................................default
1
Enable
1
Interrupt Active High Output
0
Disable ...................................................default
1
Enable
0
Reserved
........................................ always reads 0
Revision 1.71 June 9, 2000
Offset 4B –Temperature Interrupt Configuration ........ RW
7-6
TSENS1 Value Low-Order Bits ..................def = 00
Upper 8 bits are stored in offset 20h
5-4
TSENS3 Hot Temp Interrupt Mode ...........def = 01
TSENS2 Hot Temp Interrupt Mode ...........def = 01
3-2
1-0
TSENS1 Hot Temp Interrupt Mode ...........def = 01
The following applies to each of the above 3 fields
00 Default Interrupt Mode. An interrupt occurs if
the temperature goes above the hot limit. The
interrupt will be cleared once the status register
is read, but will be generated again when the
next conversion is completed. Interrupts will
continue to be generated until the temperature
goes below the hysteresis limit.
01 One-Time Interrupt Mode.
generated if the temperrature goes above the
hot limit. The interrupt will be cleared when
the status register is read. Another interrupt
will not be generated until the temperature first
drops below the hysteresis limit............. default
10 Comparator mode. An interrupt occurs if the
temperature goes above the hot limit. This
interrupt remains active until the temperature
goes below the hot limit (i.e., no hysteresis).
11 Default Interrupt Mode (same as 00)
-105-
Hardware Monitor I/O Space Registers
VT82C686B
An interrupt is