Specifications of SAM3N4C

Flash (kbytes)
256 Kbytes
Pin Count
100
Max. Operating Frequency
48 MHz
Cpu
Cortex-M3
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Quadrature Decoder Channels
2
Usb Speed
No
Usb Interface
No
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
24
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
28.11.1
Name:
Addresses: 0x40018000 (0), 0x4001C000 (1)
Access:
Reset:
• START: Send a START Condition
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a
write operation, a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
• STOP: Send a STOP Condition
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
• MSEN: TWI Master Mode Enabled
0 = No effect.
1 = If MSDIS = 0, the master mode is enabled.
Note:
• MSDIS: TWI Master Mode Disabled
0 = No effect.
1 = The master mode is disabled, all pending data is transmitted. The shifter and holding characters (if it contains data) are
transmitted in case of write operation. In read operation, the character being transferred must be completely received
before disabling.
492
492
SWRST
– In single data byte master read, the START and STOP must both be set.
– In multiple data bytes master read, the STOP must be set after the last data received but one.
– In master read mode, if a NACK bit is received, the STOP is automatically performed.
– In master data write operation, a STOP condition will be sent after the transmission of the current data is
31
23
15
7
finished.
Switching from Slave to Master mode is only permitted when TXCOMP = 1.
SAM3N
SAM3N
TWI Control Register
TWI_CR
Write-only
0x00000000
QUICK
30
22
14
6
SVDIS
29
21
13
5
SVEN
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
STOP
25
17
9
1
11011A–ATARM–04-Oct-10
11011A–ATARM–04-Oct-10
START
24
16
8
0

Related parts for SAM3N4C