Page 1
Shield Finger Scalable Height From 1.24mm to 3.4mm 1. SCOPE 1.1. Content This specification covers the requirements for product performance test methods and quality assurance provisions of the scalable spring finger. Applicable product descriptions and part numbers are as shown ...
Page 2
... Final examination of Product 3.5.3 Low Level Contact Resistance(LLCR) 3.5.4 Temperature Rise 3.5.5 Normal Force 3.5.6 Durability TE Connectivity (Shanghai) ASHL-0005- ES REV A Requirements Meets requirements of Visual inspection. EIA-364-18. product drawing Meets visual requirements Visual inspection. EIA-364-18. Electrical Requirements Initial Æ Max. Subject mated specimens Final Æ Max. ...
Page 3
... Cold test (non operational) 3.5.13 Heat test (operational) 3.5.14 Cold test (operational) TE Connectivity (Shanghai) ASHL-0005- ES REV A No discontinuities of 1 Subject mated specimens to 30G’s microsecond or longer half-sine shock pulses of 6 duration. milliseconds duration. Three shocks 80 milliohms Max.(Initial) in each direction applied along 3 ...
Page 4
... Vibration Sinusoidal Shall meet visual requirements, show no physical damage, and meet requirements of additional tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure 2. TE Connectivity (Shanghai) ASHL-0005- ES REV A Initial Æ Max. Subject mated specimen at nominal Final Æ Max. ...
Page 5
... Product Qualification and Requalification Test Sequence (a) Numbers indicate sequence in which tests are performed. (b) Precondition specimens with 10 durability cycles. TE Connectivity (Shanghai) ASHL-0005- ES REV A Figure 2 Figure 3 Figure 4 PAGE NO 5/8 REV LOC 108-115008 A2 ES ...
Page 6
... TE Connectivity (Shanghai) ASHL-0005- ES REV A Figure 5 Figure 6 Figure 7 Figure 8 PAGE NO 6/8 REV LOC 108-115008 A2 ES ...
Page 7
... TE Connectivity (Shanghai) ASHL-0005- ES REV A Figure 9 Figure 10 Figure 11 Figure 12 PAGE NO 7/8 REV LOC 108-115008 A2 ES ...
Page 8
... Spring Finger 124 1551572-4 Spring Finger 1.80 1551573-4 Spring Finger 2.15 1551574-4 Spring Finger 2.60 1551575-4 Spring Finger 3.0 1551576-4 Spring Finger 3.4 4. QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Each test group shall consist of a minimum of 5 specimens ...