292323-6 TE Connectivity, 292323-6 Datasheet
292323-6
Specifications of 292323-6
Related parts for 292323-6
292323-6 Summary of contents
Page 1
Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods and quality requirements of AMP* Universal Serial Bus(USB) consortium plug and receptacle connectors. These connectors are mounted plug and printed circuit board mounted receptacle connectors. 1.2 ...
Page 2
Requirements: 3.1 Design and Construction: Product shall be of the design, construction and physical dimensions specified on the applicable product drawing. 3.2 Materials: A. Contact: (1) Plug: Copper alloy: gold over palladium nickel plating on contact area, tin plating ...
Page 3
Test Requirements and Procedures Summary: Para. Test Items 3.5.1 Examination of Product 3.5.2 Termination Resistance 3.5.3 Insulation Resistance 3.5.4 Dielectric Withstanding voltage 3.5.5 Capacitance 3.5.6 Vibration Random 3.5.7 Physical Shock 3.5.8 Mating Force Tyco Electronics AMP Shanghai Ltd ASHL-0005- ...
Page 4
Para. Test Items 3.5.9 Unmating Force 3.5.10 Cable Retention Force 3.5.11 Durability 3.5.12 Solder ability 3.5.13 Thermal Shock 3.5.14 Temperature life 3.5.15 Humidity-Temperature Cycling 3.5.16 Mixed flowing Gas Shall meet visual requirement, show no physical damage and shall meet requirement ...
Page 5
Product Qualification and Requalification Test Sequence Examination of Product Termination Resistance Insulation Resistance Dielectric Withstanding Voltage Capacitance Solder ability Vibration Physical Shock Durability Mating Force Unmating force Cable Retention Thermal Shock Humidity-Temperature Cycling Temperature Life Mixed flowing gas (a) ...
Page 6
A minimum of 30 contacts shall be selected and identified for each test group. Unless otherwise specified, these contacts shall be used for all measurements. B. Test Sequence Qualification inspection shall be verified testing samples as specified in Figure ...
Page 7
P.C.BOARD CONTACT TAIL Tyco Electronics AMP Shanghai Ltd ASHL-0005- ES REV A V SERIAL BUS PLUG POINT OF WIRE TERMINATION SERIAL BUS RECEPTACLE A Figure 3 Termination Resistance Measurement Point DISCONTINUITY A MONITOR UPPER CLAMP P.C.BOARD CABLE SERIAL BUS RECEPTACLE ...