849813-5 TE Connectivity, 849813-5 Datasheet

849813-5

Manufacturer Part Number
849813-5
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 849813-5

Product Type
Lead Assembly
Mount Angle
Straight
Cap Material
Glass-Filled Polyester
Wire Size (mm² [awg])
16
Operating Voltage (kvdc)
10
Shielded
No
Lead Assembly Type
Double-End
Assembly Length (mm [in])
609.60 [24.000]
Barrel Depth (mm [in])
13.50 [0.530]
Positive Stop Ferrule
Without
Wire Color
White (Standard)
Cap Color
Green
Wire Insulation
Silicone
Preloaded
Yes
Rohs/elv Compliance
Not reviewed for ELV/RoHS compliance
Lead Free Solder Processes
Not reviewed for lead free solder process
DESIGN OBJECTIVES
The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore
Tyco Electronics makes no representation or warranty, express or implied, that the product will comply with these requirements. Further,
Tyco Electronics may change these requirements based on the results of additional testing and evaluation. Contact Tyco Electronics
Engineering for further details.
1.
1.1.
1.2.
2.
2.1.
2.2.
2.3.
3.
3.1.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers perform ance, tests and quality requirem ents for the Tyco Electronics LGH
standard high voltage 1/2I, 1/2LI, 1I, 1LI, 2I, 3I and 4I series m olded end leads and receptacles. These
leads and receptacles are designed for com m ercial, industrial and m ilitary type applications requiring
operation over wide environm ents.
Qualification
W hen tests are perform ed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be perform ed using the applicable inspection plan and product drawing.
APPLICABLE DOCUM ENTS
The following docum ents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the docum ent applies. In the event of conflict between the
requirem ents of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirem ents of this specification and the referenced docum ents,
this specification shall take precedence.
Tyco Electronics Docum ents
!
!
!
!
Com m ercial Standard
EIA-364:
Military Standard
MIL-STD-202: Test Methods For Electronic And Electrical Com ponent Parts
REQUIREM ENTS
Design and Construction
Product shall be of the design, construction and physical dim ensions specified on the applicable product
drawing.
109 Series: Test Specifications as indicated in Figure 1
109-197: Test Specification (AMP Test Specifications vs EIA and IEC Test Methods)
114-
501-
: Application Specification
: Qualification Test Report
PRELIMINARY
Electrical Connector/Socket Test Procedures Including Environm ental Classifications
| Indicates change
*Trademark
Design
Objectives
Standard LGH Connectors,
Series 1/2I, 1/2LI, 1I, 1LI, 2I, 3I and 4I
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-36033
Rev O2
1 of 6
LOC B

Related parts for 849813-5

849813-5 Summary of contents

Page 1

... PRELIMINARY Product shall be of the design, construction and physical dim ensions specified on the applicable product drawing. ©2011 Tyco Electronics Corporation, | Indicates change a TE Connectivity Ltd. Company *Trademark All Rights Reserved TE logo is a trademark. For latest revision, visit our website at www.te.com/documents. ...

Page 2

Materials Materials used in the construction of this product shall be as specified on the applicable product drawing. 3.3. Ratings ! Voltage: • 1/2I: 10 kilovolts • 1/2LI: 15 kilovolts • 1I: 20 kilovolts • 1LI: 25 kilovolts • ...

Page 3

Test Description Vibration, sinusoidal. Mechanical shock. Durability. Contact engaging force. Contact separating force. Therm al shock. Hum idity, steady state. Tem perature life. Rev O2 Requirem ent MECHANICAL No discontinuities icroseconds or longer duration. See Note. No ...

Page 4

Test Description Barom etric pressure, tem perature cycling. Herm etic seal. Shall meet visual requirements, show no physical damage, and meet requirements of additional NOTE tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure 2. ...

Page 5

QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specim en Selection Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 28 lead assem ...

Page 6

Gage Num ber 1 2 (a) Contact: Size 16 NOTE (b) Material: Tungsten carbide Rev O2 Figure 3 Contact Resistance Measurem ent Points A Dim ension .0165 +.0001/-.0000 .0635 +.0000/-.0001 Figure 4 Engaging & Separating Gage 108-36033 B Dim ension ...