505038-1 TE Connectivity, 505038-1 Datasheet
505038-1
Specifications of 505038-1
Related parts for 505038-1
505038-1 Summary of contents
Page 1
SCOPE 1.1. Content This specification covers perform ance, tests and quality requirem ents for SHUR-PLUG* and SHUR-PLUG* receptacles. The .180 inch diam eter SHUR-PLUG is only available as a straight contact while SHUR-PLUG receptacles are available in straight and ...
Page 2
Ratings ! Voltage: 110 volts DC ! Current: See Figure 3 for applicable current carrying capability ! Tem perature: -40 to 105 C 3.4. Perform ance and Test Description Product is designed to m eet the electrical, m echanical ...
Page 3
Test Description Sinusoidal vibration. Mechanical shock. Durability. Mating force. Unm ating force. Hum idity/tem perature cycling. Tem perature life. Shall meet visual requirements, show no physical damage, and meet requirements of additional NOTE tests as specified in the Product Qualification ...
Page 4
Product Qualification and Requalification Test Sequence Initial exam ination of product LLCR Contact resistance, specified current Tem perature rise vs current Crim p tensile Sinusoidal vibration Mechanical shock Durability Mating force Unm ating force Hum idity/tem perature cycling Tem ...
Page 5
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specim en Selection Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Each test group shall consist inim ...
Page 6
Percent Connector Loading Single Contact To determine acceptable current carrying capacity for percentage connector loading and wire gage NOTE indicated, use the Multiplication Factor (F) from the above chart and multiply it times the Base rated Current for a single ...