DS80C323 Maxim, DS80C323 Datasheet - Page 8

no-image

DS80C323

Manufacturer Part Number
DS80C323
Description
The DS80C320/DS80C323 are fast 80C31/80C32-compatible microcontrollers
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS80C323
Manufacturer:
LT
Quantity:
177
Part Number:
DS80C323-ECD
Manufacturer:
DALLAS
Quantity:
2 463
Part Number:
DS80C323-ECD
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C323-ECD+
Manufacturer:
Maxim
Quantity:
169
Part Number:
DS80C323-ECD+
Manufacturer:
Maxim
Quantity:
27
Part Number:
DS80C323-ECD+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C323-ECD+T&R
Manufacturer:
MAXIM
Quantity:
1 200
Part Number:
DS80C323-ECD+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C323-END
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C323-END
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS80C323-END+
Manufacturer:
Maxim Integrated
Quantity:
10 000
DS80C320/DS80C323 High-Speed/Low-Power Microcontrollers
INSTRUCTION SET SUMMARY
All instructions in the DS80C320/DS80C323 perform the same functions as their 80C32 counterparts.
Their effect on bits, flags, and other status functions is identical. However, the timing of each instruction
is different. This applies both in absolute and relative number of clocks.
For absolute timing of real-time events, the timing of software loops will need to be calculated using the
Table 1. However, counter/timers default to run at the older 12 clocks per increment. Therefore, while
software runs at higher speed, timer-based events need no modification to operate as before. Timers can
be set to run at 4 clocks per increment cycle to take advantage of higher speed operation.
The relative time of two instructions might be different in the new architecture than it was previously. For
example, in the original architecture, the “MOVX A, @DPTR” instruction and the “MOV direct, direct”
instruction used two machine cycles or 24 oscillator cycles. Therefore, they required the same amount of
time. In the DS80C320/DS80C323, the MOVX instruction can be done in two machine cycles or eight
oscillator cycles, but the “MOV direct, direct” uses three machine cycles or 12 oscillator cycles. While
both are faster than their original counterparts, they now have different execution times from each other.
This is because in most cases, the DS80C320/DS80C323 use one cycle for each byte. The user concerned
with precise program timing should examine the timing of each instruction for familiarity with the
changes. Note that a machine cycle now requires just four clocks, and provides one ALE pulse per cycle.
Many instructions require only one cycle, but some require five. In the original architecture, all were one
or two cycles except for MUL and DIV.
8 of 38