The MAX9450/MAX9451/MAX9452 clock generators provide high-precision clocks for timing in SONET/SDH systems or Gigabit Ethernet systems
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX9450EHJ+
Manufacturer:
Microsemi Consumer Medical Product Group
Quantity:
10 000
Part Number:
MAX9450EHJ+T
Manufacturer:
Microsemi Consumer Medical Product Group
Quantity:
10 000
where f
is the frequency of the reference clock, M (1 to 32,768)
is the dividing factor in the feedback loop, Ni (1, 2, 3, 4,
5, 6, 8, 16) are the dividing factors of the outputs, and P
(1 to 256) is the dividing factor to the input reference
clock. It is possible to set various frequencies at the
two differential CLK_ outputs with this configuration.
For example, in 10 Gigabit Ethernet or SONET applica-
tions, set the dividing factors to generate the required
frequencies, as shown in Table 1.
The MAX9450/MAX9451/MAX9452 clock-failure-detec-
tion function monitors the two reference inputs simultane-
ously. If a reference input clock signal (IN_) does not
transition for two or more VCO cycles, the device reports
a failure by setting INT high and bit CR7[6] or CR7[5] to
1. See Table 9. After a reference clock failure, the moni-
tor switches to the other valid input reference. At the
same time, the clock monitor loads CR7 with the status of
the reference clocks and which input is selected. The
mapping of CR7 is given in Table 9. If one of the inputs is
disabled according to the bits in CR5[3:2], then the mon-
itor is disabled.
The response of the MAX9450/MAX9451/MAX9452 to a
detected input failure depends on the setting of the
revert function. If the failed input recovers from the
failure, INT and CR7[5:6] resets to zero if revert is acti-
vated. If the recovered input is selected by CR5[4] as
the default input reference, the MAX9450/MAX9451/
MAX9452 reselect this input. If the revert function is not
activated, once an input failure is detected, the monitor
remains in the failure state with INT = 1 and CR7[5:6] =
1, until the MAX9450/MAX9451/MAX9452 are reset.
Activate the revert function using the bit CR5[1].
Table 1. Output Frequency Selection and Register Content Values
FREQUENCY
CRYSTAL
(MHz)
CLKn
125
125
50
is the frequency at the CLKn output, f
_______________________________________________________________________________________
10 GIGABIT ETHERNET
INPUT CLK: 50MHz
P
2
2
2
M
2
5
5
Input Clock Monitor
Ni
1
2
1
High-Precision Clock Generators
Failure Detection
Revert Function
FREQUENCY
OUTPUT
(MHz)
62.5
125
50
REF
Reset the fault by toggling CMON from low to high,
toggling MR or CR6[4] from low to high, or by toggling
the bit CR5[0] from low to high. In revert mode, when
the monitor is reset, INT and CR7[5:6] reset to zero and
the default input is the one indicated by CR5[4].
The holdover function locks the output frequency to its
nominal value within ±20ppm. Activate this function by
setting CR6[7] to 1. The MAX9450/MAX9451/MAX9452
enter holdover when the devices detect a failure from
both input references. Setting CR6[6] to 1 forces the
device into the holdover state, while resetting CR6[6]
exits holdover.
Use a reset holdover. If the revert function is activated
once an input is recovered from the failure, the device
also exits holdover and switches to the recovered input
reference. If both inputs recover simultaneously, the
device switches to the default input.
VCXO frequency during holdover is the value of the
frequency right before the failure of inputs.
When CR6[5] goes from 0 to 1, the value of the VCXO
frequency is acquired and stored. The VCXO can be
switched to this acquired frequency by setting CR6[1]
to 1. Such a transition can happen in both the normal
mode of operation and the holdover mode.
The MAX9450/MAX9451/MAX9452 also feature PLL
lock detection. The MAX9450/MAX9451/MAX9452
compare the frequency of the phase-detector input with
the output frequency of the loop frequency divider.
When these two frequencies deviate more than 20ppm,
the LOCK output goes high. At power-up, LOCK is
high. LOCK goes low when the PLL locks. PLL lock
time also depends on the loop filter bandwidth.
FREQUENCY
with Integrated VCXO
CRYSTAL
155.52
155.52
(MHz)
51.84
77.76
INPUT CLK: 19.44MHz
P
1
1
1
1
Failure-Detection Monitor Reset
SONET
M
8
4
8
4
PLL Lock Detect
Ni
1
1
1
2
Holdover Function
FREQUENCY
OUTPUT
155.52
(MHz)
51.84
77.76
77.76
9