PM5365 PMC-Sierra, Inc., PM5365 Datasheet - Page 53

no-image

PM5365

Manufacturer Part Number
PM5365
Description
TEMUX/TEMAP/TECT3 T1/E1 FRAMER, VT/TU MAPPER, M12/M13 MUX DRIVER MANUAL
Manufacturer
PMC-Sierra, Inc.
Datasheet
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1991611, Issue 2
Resetting Devices: temuxReset
This function applies a software reset to the TEMUX/TEMAP/TECT3 device and in doing so
reinitializes the DDB for this device. This function is typically called before reinitializing the
device (via
Deactivating Devices: temuxDeActivate
This function deactivates the device from operation. Interrupts are masked and the device is put
into a quiet state via section enable bits.
Returns
Valid States
Side Effects
Prototype
Inputs
Outputs
Returns
Valid States
Side Effects
Prototype
Inputs
temuxInit
Success =
Failure =
PRESENT
Changes the STATE of the DEVICE to INACTIVE
INT4 temuxReset (sTMX_HNDL devId)
devId
None
Success =
Failure =
ACTIVE, INACTIVE
Changes the STATE of the DEVICE to PRESENT
INT4 temuxDeActivate (sTMX_HNDL devId)
devId
).
TMX_OK
TMX_OK
TMX_ERR_ARG
TMX_ERR_NOTREADY
TMX_ERR_INVALID
TMX_ERR_NOTPRESENT
TMX_ERR_CLOSED
TMX_ERR_CLOSED
TMX_ERR_NOTREADY
TMX_ERR_DEACTIVATE
TMX_ERR_INVALID
TMX_ERR_NOTINACTIVE
TMX_ERR_HNDL
TMX_ERR_HNDL
TEMUX/TEMAP/TECT3 (PM8315, PM5365, PM4328) Driver Manual
: device handle (from
: device handle (from
temuxAdd
temuxAdd
Application Programming Interface
)
)
53