HDBF43A1DC Shoulder Electronics, HDBF43A1DC Datasheet - Page 4

no-image

HDBF43A1DC

Manufacturer Part Number
HDBF43A1DC
Description
Saw Filter Hdbf43a1dc
Manufacturer
Shoulder Electronics
Datasheet
2.2. Circuit construction, measurement circuit
3.Characteristics
www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:info@shoulder.cn
SAW FILTER
Standard
atmospheric
conditions
Operating
temperature rang
Storage
temperature rang
Reference
temperature
Items
Unless otherwise specified , the standard rang of
atmospheric conditions for making
measurements and tests is as follows;
Operating temperature rang is the rang of ambient
temperatures in which the filter can be
operated continuously. -20℃ ~ +60℃
Storage temperature rang is the rang of ambient
temperatures at which the filter can be stored
without damage.
Conditions are as specified elsewhere in these
specifications. -40℃ ~ +70℃
+25℃
Ambient temperature
Relative humidity
Air pressure
Conditions
: 86kPa to 106kPa
: 15℃ to 35℃
: 25% to 85%
HDBF43A1Dc SIP5Dc
There shall be no
Specifications
damage.
Page 4 of 8

Related parts for HDBF43A1DC