CPCI325D-101C C&D Technologies., CPCI325D-101C Datasheet - Page 2

no-image

CPCI325D-101C

Manufacturer Part Number
CPCI325D-101C
Description
325 Watt, 3u X 8hp Compactpci?
Manufacturer
C&D Technologies.
Datasheet
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Over Temperature Protection
Altitude
CONTROL INPUTS & WARNING SIGNALS
Signal/Indicator
Enable (EN#)
Remote Inhibit (INH#)
Power Fail Warning (FAL#)
Thermal Warning (DEG#)
Fault Indicator LED
Power Present LED
IPMI & HOT SWAP CAPABILITY
IPMI
The cPCI325D-10xC is equipped with an IPMI interface to the SM bus. Status functions include output voltage and current levels as well as the DEG warning. Output inhibit control
can be toggled under software command. For a complete specification of the firmware solution refer to Application Note ACAN-05 on our website.
HOT SWAP CAPABILITY
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed ±5%. However, routing of power
and signal lines in the mating backplane is critical to minimization of such excursions. In addition, performance can be critically affected by load characteristics including
negative resistance, resistance, and reactive components. While the control loop responses have been designed for optimum hot-swap performance over a wide range of load
characteristics, there may be instances where the voltage excursions exceed published specification. In such cases, the control loop responses can be modified to perform
optimally.
OUTPUT FAULT ISOLATION
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
EMC & SAFETY
EMI:
n
n
n
www.murata-ps.com
NEBS Compliant to GR1089 conducted emissions limit.
ETSI Compliant to ETS 300-386 conducted emissions test.
Complies with EN 61000-4-2, EN 61000-4-3, and EN 61000-4-8.
Conditions
200lfm of airflow is required to maintain full output power at 0-50ºC ambient.
Derate to 160W at 70ºC. Unit will deliver full power at 55ºC for 96 hours.
Unit is protected against thermal overload. Output will automatically restore upon recovery to acceptable temperatures.
Operating -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate
(approximately 2ºC per 1,000 ft.).
Operational function
Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this
pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Secondary referenced, active low, TTL compatible signal inhibits all outputs upon activiation.
Open collector signal indicates output fault condition. Active low.
Open collector indicates internal temperatures are approaching the thermal shutdown limit (±10ºC TYP.) Active low.
An amber LED will be ON if output voltages are not within specification. This LED can be extinguished under IPMI command.
A green LED will be ON when input voltage is present and above the minimum requirement. LED blinks at a rate of 1Hz when
input is present but output is inhibited.
Safety Agency Ratings:
Input voltage:
Input current:
Input power:
Agency approvals: UL60950, EN 60950, CE Mark (Low voltage directive).
Technical enquiries - email: mk@murata-ps.com, tel:
325 Watt
36-75 VDC
12A
430W
cPCI325D-10xC Series
325 Watt, 3U x 8HP CompactPCI™
MPS_cPCI325D-10xC.A01 Page 2 of 4
Min
-20
0
Typ
+44 (0)1908 615232
Max
70
85
Units
ºC

Related parts for CPCI325D-101C