PNP-383-P22 Universal Microwave Corporation, PNP-383-P22 Datasheet - Page 5

no-image

PNP-383-P22

Manufacturer Part Number
PNP-383-P22
Description
Intelligent Frequency Synthesizers
Manufacturer
Universal Microwave Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PNP-383-P22-G
Manufacturer:
RFMD
Quantity:
5 000
Attribute Definitions
FIGURE 2: FREQUENCY/CHANNEL (DB0 - DB23) This is a 24 bit string used to set the synthesizer’s
START Frequency, STOP Frequency, STEP Frequency, REF Frequency or CHANNEL number.
FIGURE 3: MULTIPLIER (DB24 - DB27) The data in FREQUENCY/CHANNEL (DB0-DB23) is multiplied
by 10
FIGURE 4: FUNCTION SELECT (DB28 - DB31). After the data in FREQUENCY/CHANNEL (DB0 - DB23)
is multiplied by 10
routed internally to the START, STOP, STEP, REF or CHANNEL registers based on the contents of FUNC-
TION SELECT as shown below.
DB23
DB27 DB26 DB25 DB24
All FUNCTION SELECT values not shown above are reserved for factory use.
FC23
DB31 DB30 DB29 DB28
FS3
M3
0
0
0
0
0
0
0
0
0
n
0
0
0
0
0
n
where the value of n is determined by the contents of MULTIPLIER (DB24-DB27) as shown below.
DBn
FCn
FS2
M2
0
0
0
0
0
0
0
0
0
n
0
0
0
0
1
DB3
FC3
FS1
M1
n
0
0
0
0
1
0
0
1
1
n
0
0
1
1
0
where the value of n is determined by the contents of MULTIPLIER (Figure 3), it is then
DB2
FC2
FS0
M0
0
0
0
0
1
0
1
0
1
n
0
1
0
1
0
10
10
10
10
10
CHANNEL. Routes data from DB0-DB23 to the CHANNEL REGISTER.
START. Routes data from DB0-DB23 to the START REGISTER.
STOP. Routes data from DB0-DB23 to the STOP REGISTER.
STEP. Routes data from DB0-DB23 to the STEP REGISTER.
REFERENCE. Routes data from DB0-DB23 to the REFERENCE REGISTER
DB1
FC1
0
0
1
1
1
0
1
2
3
n
X contents of DB0-DB23
X contents of DB0-DB23
X contents of DB0-DB23
X contents of DB0-DB23
X contents of DB0-DB23
DB0
FC0
0
1
0
1
1
0
1
2
3
15
FUNCTION SELECT
MULTIPLIER
FREQUENCY/CHANNEL
PNP-383-P22