B58620T0510A001 EPCOS AG, B58620T0510A001 Datasheet - Page 6

no-image

B58620T0510A001

Manufacturer Part Number
B58620T0510A001
Description
Pressure Sensors
Manufacturer
EPCOS AG
Datasheet
Symbols and terms
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
AS SEN PD
Please read Cautions and warnings and
Important notes at the end of this document.
Pressure sensors
Pressure transmitters without casing (voltage output)
Storage temperature range T
A storage of the pressure sensor within the temperature range T
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.
Operating temperature range T
An operation of the pressure sensor within the temperature range T
will not affect the performance of the pressure sensor.
Compensated temperature range T
While operating the pressure sensor within the temperature range T
the deviation of the output signal from the values at 25 °C will not exceed the temperature coefficients.
Out of the compensated temperature range, the deviations may increase.
Rated pressure p
Within the rated pressure range 0 up to p
to this specification.
Overpressure p
Pressure cycles within the pressure range 0 up to p
Supply voltage V
V
V
Signal output current I
I
Exceeding (e.g. short circuit) may cause irreparable damages.
DC break down voltage V
The pressure sensor withstands a high voltage between the stainless steel pressure connection and the electrical
connection V
Offset V
The offset V
Signal span (Full Scale)
Simple output:
Symmetrical output:
Non-linearity L (including pressure hysteresis)
The non-linearity is the deviation of the real sensor characteristic V
It can be approximated by a polynomial of second order, with the maximum at p
The equation to calculate the non-linearity is:
Response time t
Delay between a pressure change (10 ... 90% p
Supply voltage rejection SVR
While varying the supply voltage within the range V
the signal output change will not exceed SVR
Temperature hysteresis
The temperature hysteresis is the change of offset, starting from the value at 25 °C after a temperature change
and return to 25 °C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).
Temperature coefficient of offset TCV
Offset at temperature T
Values are valid within the compensated temperature range T
Out of the compensated temperature range, the deviation may increase.
Temperature coefficient of span TCV
Span at temperature T
Values are valid within the compensated temperature range T
Out of the compensated temperature range, the deviation may increase.
A,max
CC,max
CC,min
is the maximum permissible sink current of the signal output.
is the minimum required supply voltage, which has to be applied for normal operation.
is the maximum permissible supply voltage, which can be applied without damages.
A0
A0
CC
is the signal output V
, V
OV
10-90
A
CC
r
and GND (all short circuited) without damage.
x
V
V
x
: V
: V
A
FS
FS
FS
A0
is
= FS = V
= FS = V
(T
(T
x
st
x
) = V
) = V
a
A
FS
A
A
A0
(p = 0) at zero pressure.
(p
(+p
c
(25 °C) · [ 1 + (T
(25 °C) + V
r
FS
) – V
A0
r
) – V
r
(symmetrical output: –p
A0
L
max
A
(–p
=
r
) and the corresponding signal output change (10 ... 90% FS).
.
FS
V
r
V
)
CC,min
ov
(25 °C) · (T
A
A
p (
Page 6 of 8
p (
will not affect the performance of the pressure sensor.
x
– 25 °C) · TCV
x
r
up to V
)
)
V
V
c,min
c,min
x
A
A
CC,max
– 25 °C) · TCV
st,min
0
0
r
up to T
up to T
up to +p
A
a,min
c,min
= f(p) from the ideal straight line.
up to T
p
p
at constant pressure and temperature,
FS
x
r
up to T
up to T
]
c,max
c,max
r
) the signal output characteristic corresponds
st,max
a,max
A0
c,max
x
= p
,
r
/ 2 .
CAU-T series
2009-04-06

Related parts for B58620T0510A001