DLP-PU TDK Corp., DLP-PU Datasheet

no-image

DLP-PU

Manufacturer Part Number
DLP-PU
Description
Power Supply Parallel Or Redundancy Module
Manufacturer
TDK Corp.
Datasheet
ITEMS
Input Voltage Range
Number of inputs
Maximum Input Current
Maximum Output Current
Overcurrent protection
Voltage Drop
Maximum Reverse Voltage
LED Indicators
Input Voltage Alarm
Relay contact rating (max)
Cooling
Operating Temperature
Storage Temperature
Humidity
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Approval
Size
Weight
Warranty
Specifications
DLP-PU Series
Power Supply
Parallel or Redundancy Module
• Internal ORing Diodes
• Can Connect Two Units in Parallel
• Output Voltage Monitoring (via relays)
• DIN Rail Mounting
DLP-PU Features and Benefits
Features
MODELS
mm/in
VDC
VDC
VDC
yrs
°C
°C
A
A
g
-
-
-
-
-
-
-
-
-
-
-
-
DLP-PU Series
UL60950-1, CSA60950-1, EN60950-1, UL508, CSA22.2 No.14, EN60529 IP20, EN50178 Cat 1
Relay off when input is <19.2V (±1%) or > 30V (±5%). NO and NC contacts
Relay Contacts to Chassis; >10M Ohms at 25°C, 70%RH and 500VDC
Benefits
• Allows Redundant Operating
• Enables System Scalability
• Remote Alarm Notification
• Easier System Integration
Operating: 30 - 90%RH, Storage: 10 - 95%RH (non condensing)
Non operating, mounted on DIN Rail,10-55Hz (sweep for 1 min),
28VDC, 1A or 120VAC, 0.5A (5mA minimum recommended)
Input or Output - Chassis, Input or Output - Relay Contacts,
Input or Output - Chassis, Input or Output - Relay Contacts,
Two green LEDs indicating each input is "good"
-10 to +70, derate linearly to 60% from 60 to 70
Relay Contacts to Chassis; 500VAC for 1 min.
9.8m/s
50 x 97 x 110, (1.97x 3.81 x 4.33)
• OR-ing Diodes Included
• Alarm Signals
• LED Indicators
• DIN Rail Mounting
Key Market Segments & Applications
Industrial Controls:
Factory Automation:
Test & Measurement:
2
constant X, Y, Z each for 1 hour
20 per input
Convection
DLP-PU/E
-30 to +85
196m/s
3 Years
21 - 28
None
Two
470
0.5
20
35
2
Motor Control Systems
Process Control, Automotive,
Chemical Processing
Burn in & Test, Instrumentation
Measurement
1

Related parts for DLP-PU

DLP-PU Summary of contents

Page 1

... DLP-PU Series Power Supply Parallel or Redundancy Module DLP-PU Features and Benefits Features • Internal ORing Diodes • Can Connect Two Units in Parallel • Output Voltage Monitoring (via relays) • DIN Rail Mounting Specifications MODELS ITEMS Input Voltage Range VDC Number of inputs ...

Page 2

... Outline Drawing DLP-PU Series IND.CONT.EQ. 16LU BAR CODE IND.CONT.EQ. 16LU BAR CODE DLP-PU Series ...

Page 3

... Block Diagram DLP-PU Series Power Supply A+ Power Supply B+ Relay B -V For full data and drawings please visit D Relay www.emea.tdk-lambda.com/www/dlp DLP-PU Series +V + Output +V + Alarm Alarm ...

Page 4

... BP 1077-Gometz-le-Chatel 91940 LES ULIS France Tel: + Fax: + france@fr.tdk-lambda.com www.fr.tdk-lambda.com LOCAL DISTRIBUTION DLP-PU Jan09 v1 4 www.emea-tdk-lambda.com TDK-Lambda Italy Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: + Fax: + info ...

Related keywords