CONTACT ELECTRICAL CHARACTERISTICS
Date of issue: 9/07
Minimum
operating cycles
ENGINEERING DATA SHEET
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Featuring
www.esterline.com
200,000 cycles
50,000 cycles
10,000 cycles
50,000 cycles
50,000 cycles
APPLICATION NOTES:
001
002
023
APPLICABLE SOCKET:
S501
50 cycles
LEACH
©
power and control solutions
Contact rating per
pole and load type
resistive load
inductive load (L/R=5ms)
motor load
lamp load
resistive overload
at 25% rated resistive load
Non latching hermetically sealed relay
Contact arrangement
Coil supply
Meets the requirements of
Qualified to
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions max.
of case in mm
Balanced-force design
Hermetically sealed, corrosion protected metal can
Balanced force armature with linked contacts
@28 Vdc
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
- 165 -
25
12
10
50
5
@115 Vac 400 Hz
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
Load Current in Amps
25
12
10
80
HERMETICALLY SEALED RELAY
5
3 PDT
Alternating current
MS 27743
CECC16101-032
CECC16103-805
28 Vdc; 115 Vac, 400 Hz
85 grams max
26 x 25.4 x 26
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
@115/200 Vac 400 Hz
3 PDT/25 AMP
25
15
10
5
Page 1 of 4
M501

Related parts for M501-E4F

M501-E4F Summary of contents

Page 1

... Sarralbe Buena Park, CA 90622 France . . . . Tel: (01) 714-736-7599 Tel: (33 Fax: (01) 714-670-1145 Fax: (33 165 - M501 3 PDT/25 AMP 3 PDT Alternating current MS 27743 CECC16101-032 CECC16103-805 28 Vdc; 115 Vac, 400 Hz 85 grams max @115/200 Vac 400 Hz 25 ...

Page 2

... VRMS / 50 Hz 350 VRMS / 50 Hz 100 M 30G / 75 to 3000 Hz 20G / 75 to 3000 Hz 200G / 6 ms 50G / µ max 50 ms max 1 ms max 150 mV max 175 mV max - 166 - M501 Vac / 60-400 115 30 124 0.12 0.028 -45° +85 ° C min ...

Page 3

... MAX 1 15.9 35.5 36.7 44 MAX ±0.05 Ø1.01 2 ±0.5 ±0.5 7.6 9.5 SOLDER HOOKS - 167 - D 1 ±0.1 7.5 ±0.15 4 ±0.15 4 3.8 15.9 35.5 36.7 44 MAX M3.5 OR 6.32 UNC UNC 15 M3 17.5 ±0.05 Ø1.6 ±0.05 Ø2.36 +0.05 Ø2.36 -0.025 SILICON GASKET SHORE A15-30 ±0.1 1.3 ±0.5 15.9 GOLD PLATED PINS M501 9.5 1.2 MAX Ø8 MAX = 7.6 7.6 4 Page ...

Page 4

... C: Circuit breaker compatibility hour sec; 100 A / 1.2 sec 250 A / 0.2 sec; 350 A /0.1 sec - D: low level: 10 µ Quality level 006: Model qualified to CECC16303-809 - ER: Please contact factory. TYPICAL CHARACTERISTICS Coil resistance/temperature change: See application note no. 001 G Date of issue: 9/ 168 - 2 3 M501 M501 Page ...

Page 5

Application notes CORRECTION DUE TO COIL COPPER WIRE RESISTANCE 1.8 1.6 1.4 1.2 1 0.8 0.6 -80 -30 Nominal Resistance at 25°C Example: Coil resistance at 25°C: 935 ohms. What 125°C? Correction coefficient on diagram is: 1.39 ...

Page 6

Application notes Date of issue: 6/00 LIFE CAPABILITY VERSUS VOLTAGE - 2 - N°002 Page ...

Page 7

Application notes Date of issue: 6/00 LIFE CAPABILITY VERSUS VOLTAGE - 3 - N°002 Page ...

Page 8

Application notes Definition and applicability This application note defines the minimum distance between relays to maintain the whole performances of the relays as given in our data sheets. Phenomenon analysis Each relay generates a magnetic field either when relay is ...

Page 9

... Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component. Date of issue: 9/08 S500, S501, S502, S550 BASIC SOCKET SERIES DESIGNATION FOR: SERIES M500 (DC Coil), M501 (AC Coil), M502 (DC Coil), M550 (DC Coil), T531, CS500 DESIGNED TO THE STANDARDS AND REQUIREMENTS OF: MIL-PRF-12883/48 & /54 ...

Page 10

TERMINAL LAYOUT CODE A S500 FOR CS500 RELAYS MOUNTING HARDWARE CODE 1 : 05-284-12 LOOSE UNC HARDWARE BOTTOM MOUNT MOUNTING TORQUE NUT 4/40:0,45 ±0,1 Nm NUT 10-32:1,2 MAX :3,6 mm BOTTOM MOUNT ...

Page 11

WIRE INSULATION DIAMETER FOR SEAL TO GROMMET Code A CONTACT SIZE AND STYLE Crimp end to accomodate AWG 20-20-24 05 913 00 (for contact code 8 +10) Contact mating end #20 31 236 00 (for contact code ...

Page 12

SOCKET NUMBERING SYSTEM 1-Basic socket designation________________________| 2-Terminal Layout_____________________________________| 3-Mounting Hardware_______________________________________| 4-Grommet to seal on wire insulation__________________________| 5-Contact size and style___________________________________________| MS/LEACH CROSS PART NO. AND MATING RELAYS MS - Number MIL-S-12883/48A Date of issue: 3/06 LEACH P/N -01 S500-A8A11 -02 ...

Related keywords