STP-2000-2115 Signal Transformer Inc., STP-2000-2115 Datasheet
STP-2000-2115
Related parts for STP-2000-2115
STP-2000-2115 Summary of contents
Page 1
Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! Audio • Battery Chargers • Communication • Dental Equipment • Elevator Controls • Fire & Safety Gaming • HVAC • Industrial Controls • Lighting • ...
Page 2
... Smaller size and weight per VA (See our MPI, SHE, HPI & M4L series) • Better performance through improved volumetric efficiency • Superior suppression of radiated magnetic field (See our STP, IF, LPI series) • Large VA, 3 Phase Transformers, Buck Boost / Isolation transformers in NEMA 3R enclosure (See our 3PH & ICT series) • ...
Page 3
How to Order Simply call 516-239-5777 to speak with a customer service representative who is eager to answer your inquiry. If you wish, you may fax your order to our 24-hour fax line 516-239-7208 or mail your purchase order to ...
Page 4
... Transformer Accessories and Connectors ©2008 Signal Transformer — Specification subject to change without notice. 07.08 Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208 sales@signaltransformer.com • techhelp@signaltransformer.com 3 Product Family Page Number SHE 4 HPI 5 MPI 6-7 STP 8 M4L 9 A41 10-11 A41-L See website A41* 12-13 CL2 14-15 241 & DP-241 16-17 241-L & ...
Page 5
Super High Efficiency Transformers High Reliability with Clean Efficient Power Transfer for Optimal Performance VA Secondary RMS Rating Part Number Size Series SHE-250 250 230V @ 1.1A SHE-500 500 230V @ 2.2A SHE-750 750 230V @ 3.3A SHE-1000 1000 230V ...
Page 6
High Power International Transformers Greater Performance in Less Space and Weight Part Number Inches (mm) 7.06 5.1 6.10 HPI-12* (179.3) (129.6) (154.9) 7.06 5.5 6.10 HPI-15* (179.3) (139.7) (154.9) 7.06 5.89 6.10 HPI-17* (179.3) (149.7) (154.9) 7.50 ...
Page 7
Multi-Purpose International Transformers High Performance with Greater Volumetric Efficiency 115V Secondary 100V #1 50/ Primary 115V Secondary 100V #2 50/ Primary ESS Custom versions available upon request. www.signaltransformer.com Signal’s MPI transformers feature higher volumetric efficiency for ...
Page 8
Multi-Purpose International Transformers High Performance with Greater Volumetric Efficiency VA L Size 3.75 200 (95.3) 4.12 250 (104.8) 4.12 300 (104.8) 4.12 400 (104.8) 5.25 650 (133.3) 5.25 900 (133.3) Custom versions available upon request. www.signaltransformer.com CLEARANCE SLOT (4) FOR ...
Page 9
... Custom designs available on request Part Number STP-0100-2115 STP-0150-2115 STP-0200-2115 STP-0250-2115 A A STP-0300-2115 STP-0400-2115 STP-0500-2115 B STP-0600-2115 STP-0800-2115 STP-1000-2115 STP-1200-2115 STP-1600-2115 STP-2000-2115 Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208 sales@signaltransformer.com • techhelp@signaltransformer.com 8 Power Dimensions 2 Weight Range Inches (mm 4.2 1.4 100 ...
Page 10
More-4-Less™ International Transformers Greater Performance in Less Space Clearance slot (4) for mounting screw VA Part Number Size M4L-1-3 M4L-2-3 M4L-3-3 300 M4L-1-4 M4L-2-4 M4L-3-4 450 M4L-1-6 M4L-2-6 M4L-3-6 600 M4L-1-10 M4L-2-10 M4L-3-10 1000 Custom versions available ...
Page 11
All-4-One™ International Transformers Chassis Mount International Standards at Lower Cost and Better Performance 6 5 115/230V 50/60Hz 2 1 Indicates like polarity Note: VDE certified A41 Series transformers with standard length and color lead wires are readily available. See website ...
Page 12
All-4-One™ International Transformers Chassis Mount International Standards at Lower Cost and Better Performance 9 Dimensions Inches Size (mm) 2.81 2.14 2.31 25 (71.4) (54.4) (58.7) 3.12 2.14 2.68 43 (79.4) (54.4) (68.2) 2.50 2.52 3.00 80 ...
Page 13
All-4-One™ International Transformers Chassis Mount with Lead Wires International Standards at Lower Cost and Better Performance Lead Wires • Hook up lead wire style UL1015, CSA TEW • Rated 600V -40° to +105° C • Passes UL VW-1 (flame test) ...
Page 14
All-4-One™ International Transformers Chassis Mount with Lead Wires International Standards at Lower Cost and Better Performance Dimensions Inches Size (mm) 2.81 2.14 2.31 25 (71.4) (54.4) (58.7) 3.12 2.14 2.68 43 (79.4) (54.4) (68.2) 2.50 2.52 ...
Page 15
All-4-One™ International Triple Output Transformers - Chassis Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Requiring International Safety Certification VA DC Output Part Number Size Regulator I A41-25-512 1.25A A41-25-515 25 5V ...
Page 16
All-4-One™ International Triple Output Transformers - Chassis Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Requiring International Safety Certification Dimensions Size 2.81 2.14 2.31 25 (71.4) (54.4) (58.7) 3.12 2.14 2.68 ...
Page 17
Class 2 Transformers designed for Chassis Mounting Inherently or Non-Inherently Limited Part Number CL2-25-12 CL2-25-24 CL2-40-12 CL2-40-24 CL2-80-24 * Non-inherently limited Maximum secondary fuse value specified All primaries are 115/230 V, 50/60 Hz Custom versions available upon request. www.signaltransformer.com Signal’s ...
Page 18
Class 2 Transformers designed for Chassis Mounting Inherently or Non-Inherently Limited 9 Dimensions Size 2.81 2.14 2.31 25 (71.4) (54.4) (58.7) 3.12 2.14 2.68 40 (79.4) (54.4) (68.2) 2.50 2.53 3.00 80 (63.5) (64.3) (76.2) Custom ...
Page 19
Two-4-One™ Power Transformers Chassis Mount Split Bobbin Construction Providing Superior Isolation. Part Number Single 115V Dual 115/230V 241-3-10 Not Available 241-4-10 DP-241-4-10 241-5-10 DP-241-5-10 241-6-10 DP-241-6-10 241-7-10 DP-241-7-10 241-8-10 DP-241-8-10 241-3-12 Not Available 241-4-12 DP-241-4-12 241-5-12 DP-241-5-12 241-6-12 DP-241-6-12 241-7-12 ...
Page 20
Two-4-One™ Power Transformers Chassis Mount Split Bobbin with High Isolation CLEARANCE FOR #8 SCREW Size VA L 2.07 3 2.4 (52.6) 2. (60.3) 2. (71.4) 3. (82.6) 3. (93.7) 4.03 8 100 ...
Page 21
Two-4-One™ Power Transformers Chassis Mount with Lead Wires Split Bobbin with High Isolation Part Number Single 115V Dual 115/230V 241-3-10L Not Available 241-4-10L DP-241-4-10L 241-5-10L DP-241-5-10L 241-6-10L DP-241-6-10L 241-7-10L DP-241-7-10L 241-8-10L DP-241-8-10L 241-3-12L Not Available 241-4-12L DP-241-4-12L 241-5-12L DP-241-5-12L 241-6-12L ...
Page 22
Two-4-One™ Power Transformers Chassis Mount with Lead Wires Split Bobbin with High Isolation CLEARANCE FOR #8 SCREW Size VA L 2.07 3 2.4 (52.6) 2. (60.3) 2. (71.4) 3. (82.6) 3. (93.7) ...
Page 23
Two-4-One™ Triple Output Transformers Chassis Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Part Number DC Output Primary 50/60 Hz 115V 115/230V Regulator I Regulator II MT-6-12 DMT-6- 1.75A ±12V @ 210mA MT-6-15 ...
Page 24
Two-4-One™ Triple Output Transformers Chassis Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies VA L Size 3.25 6 (82.6) 3.68 7 (93.7) 4.03 8 (102.4) Custom versions available upon request. www.signaltransformer.com Dimensions ...
Page 25
One-4-All™ International Transformers Printed Circuit Mount International Standards at Lower Cost with Better Performance VA Secondary RMS Rating Part Number Size Series 14A-2.5R-10 2.5 10.0 VCT @ 0.25A 14A-5.0R-10 5.0 10.0 VCT @ 0.50A 14A-10R-10 10.0 10.0 VCT @ 1.00A ...
Page 26
One-4-All™ International Transformers Printed Circuit Mount International Standards at Lower Cost with Better Performance See Accessories page for screw and nut information. Mechanical Dimensions Size 1.62 1.43 1.12 2.5 (41.3) (36.5) (28.6) 1.62 1.43 1.37 5 ...
Page 27
One-4-All™ International Triple Output Transformers • Printed Circuit Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supllies Requiring International Safety Certification VA DC Output Part Number Size Regulator I 14A-20-512 750mA 14A-20-515 20 ...
Page 28
One-4-All™ International Triple Output Transformers • Printed Circuit Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supllies Requiring International Safety Certification See Accessories page for screw and nut information. Dimensions Size 2.25 ...
Page 29
Class 2 Transformers designed for Printed Circuit Mounting Inherently or Non-Inherently Limited Part Number CL2-2.5R-12 CL2-2.5R-24 CL2-5.0R-12 CL2-5.0R-24 CL2-10R-12 CL2-10R-24 CL2-20-12 CL2-20-24 CL2-30-12 CL2-30-24 CL2-50-12 CL2-50-24 Custom versions available upon request. www.signaltransformer.com Signal’s CL2 transformers are available in printed circuit ...
Page 30
Class 2 Transformers designed for Printed Circuit Mounting Inherently or Non-Inherently Limited See Accessories page for screw and nut information. Dimensions Size 1.62 1.43 1.12 2.5 (41.3) (36.5) (28.6) 1.62 1.43 1.37 5.0 (41.3) (36.5) (34.9) ...
Page 31
Flathead™ Low Profile Transformers Printed Circuit Mount For Low Power and Critical Height Applications VA Secondary RMS Rating Part Number Size Series LP-10-250 2 10VCT @ 250mA LP-10-600 6 10VCT @ 600mA LP-10-1200 12 10VCT @ 1200mA LP-10-2400 24 10VCT ...
Page 32
Flathead™ Low Profile Transformers Printed Circuit Mount For Low Power and Critical Height Applications Size 1.60 0.37 2 (40.6) (9.5) 1.60 0.37 6 (40.6) (9.5) 2.00 0.50 12 (50.8) (12.7) 1.90 0.60 24 (48.3) (15.2) 2.18 0.60 ...
Page 33
Low Profile Printed Circuit Mount Triple Output Transformers For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies 9 Part DC Output Number Primary Regulator I Regulator II 50/ VDC ±12 VDC MPL-6-12 135mA 40mA 5 ...
Page 34
Low Profile Printed Circuit Mount Triple Output Transformers For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies VA L Size 1.87 6 (47.6) 2.50 12 (63.5) Custom versions available upon request. www.signaltransformer.com Dimensions Inches ...
Page 35
International Flathead™ Low Profile Transformers • Printed Circuit Mount For Critical Height and International Safety Requirements VA Part Number Size IF-2-10 2 IF-2-12 2 IF-2-16 2 IF-2-20 2 IF-2-24 2 IF-2-30 2 IF-2-34 2 IF-2-40 2 IF-2-56 2 IF-2-230 2 ...
Page 36
International Flathead™ Low Profile Transformers • Printed Circuit Mount For Critical Height and International Safety Requirements Printed Circuit Drill Pattern 3 0.055" Dia. Plated D Through Hole Size ...
Page 37
Low Profile International Transformers Printed Circuit Mount Encapsulated Direct Plug-in Replacement for Original FlatHead™Design Low Profile Transformers VA Part Number Size Series 10-250-LPI 2.5 10 VCT @ 250 mA 12-200-LPI 2.5 12.6VCT@ 200 mA 16-150-LPI 2.5 16 VCT @ 150 ...
Page 38
Low Profile International Transformers Printed Circuit Mount Encapsulated Direct Plug-in Replacement for Original FlatHead™Design Low Profile Transformers Size 0.19 0.29 1.61 2.5 (4.8) (7.2) (40.9) 0.19 0.29 1.61 6 (4.8) (7.2) (40.9) 0.19 0.29 1.61 9 ...
Page 39
Split/Tran™ Low Power Transformers Printed Circuit Mount - Split Bobbin with High Isolation Part Number Single 115V Dual 115/230V Series 6 Pin 8 Pin ST-2-10 DST-2-10 10VCT @ 0.11A ST-3-10 DST-3-10 10VCT @ 0.25A ST-4-10 DST-4-10 10VCT @ 0.6A ST-5-10 ...
Page 40
Split/Tran™ Low Power Transformers Printed Circuit Mount - Split Bobbin with High Isolation L Size VA 1.37 2 1.1 (34.9) 1.37 3 2.4 (34.9) 1. (41.3) 1. (48.4) 2. (57.2) 2. (66.7) ...
Page 41
Printed Circuit Mount Power Transformers Miniature Low Power Transformers 6 Pin Type PC 1 115V 50 - 500 Hz 2 Indicates like polarity 8 Pin Type DPC 1 115V 50-500 115V 50-500 Hz 4 Indicates like polarity ...
Page 42
Printed Circuit Mount Power Transformers Miniature Low Power Transformers Size 1.00 1.37 1.0 (25.4) (34.92) 1.37 1.12 1.2 (34.9) (28.6) 1.62 1.25 4.4 (41.3) (31.8) 1.87 1.43 10.0 (47.6) (36.5) 1.62 2.25 24.0 (41.3) (57.2) *An optional ...
Page 43
Printed Circuit Mount Triple Output Transformers For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies 115V 50/500 Hz Part Number DC Output Primary 50/500 Hz 115V 115/230V Regulator Regulator 8 Pin 10 Pin I 5 VDC MPC-X-12 ...
Page 44
Printed Circuit Mount Triple Output Transformers For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies L W Size 1.87 1.43 X (47.6) (36.5) 1.62 2.25 Y (41.3) (57. optional slide on mounting bracket is available ...
Page 45
Conventional Rectifier Power Transformers Chassis Mount 125 115 105 0 Custom versions available upon request. www.signaltransformer.com Signal’s rectifier power transformers provide a wide variety of outputs. This series of conservatively designed transformers is manufactured using traditional materials and layer wound ...
Page 46
Conventional Rectifier Power Transformers Chassis Mount Primary 50/60 Hz Second RMS Rating Single Dual Series 115V 115/230V 10-1 DL-10-1 10VCT @ 1A 10-2 DL-10-2 10VCT @ 2A 10-4 DL-10-4 10VCT @ 4A 10-6 DL-10-6 10VCT @ 6A 10-8 DL-10-8 10VCT ...
Page 47
Conventional Rectifier Power Transformers Chassis Mount Primary 50/60 Hz Second RMS Rating Single Dual Series 115V 115/230V 16-1 DL-16-1 16VCT @ 1A 16-2 DL-16-2 16VCT @ 2A 16-4 DL-16-4 16VCT @ 4A 16-6 DL-16-6 16VCT @ 6A 16-8 DL-16-8 16VCT ...
Page 48
Conventional Rectifier Power Transformers Chassis Mount Primary 50/60 Hz Second RMS Rating Single Dual Series 115V 115/230V 36-1 DL-36-1 36VCT @ 1A 36-2 DL-36-2 36VCT @ 2A 36-4 DL-36-4 36VCT @ 4A 36-6 DL-36-6 36VCT @ 6A 36-8‡ DL-36-8 36VCT ...
Page 49
Conventional Rectifier Power Transformers Chassis Mount Primary 50/60 Hz Second RMS Rating Single Dual Series 115V 115/230V 68-1 DL-68-1 68VCT @ 1A 68-2 DL-68-2 68VCT @ 2A 68-4 DL-68-4 68VCT @ 4A 68-6‡ DL-68-6 68VCT @ 6A 68-8‡ DL-68-8 68VCT ...
Page 50
Step Down Auto Transformers - Chassis Mount Available with Receptacle and Line Cord or Leads Signal’s auto transformers provide the user the capability of adapting voltages for worldwide applications. General Specifications • Power - 100 VA to 2000 VA • ...
Page 51
Filter and Dual Chokes Chassis Mount Inductance Current Resistance Part Number MHY Amps CH-1 100 CH- CH- CH- CH- ...
Page 52
Filter and Dual Chokes Chassis Mount Series Connected Part Ind. Curr. Res. Number MHY Amps Ohms CL-1 1.4 CL-2 0.7 CL-4 0.3 CL-6- 0.15 CL-12-24 4.8 12 0.052 CL-25-50 1.2 25 0.012 ...
Page 53
Power Isolation Transformers Industrial Grade Step-Up or Step-Down Transformers SU Transformer 120 110 104 Primaries 0 120 110 104 0 Electrostatic Shield As shown on the schematic diagram the DU line incorporates dual primaries and secondaries. All four windings are ...
Page 54
Power Isolation Transformers Industrial Grade Step-Up or Step-Down Transformers Part Number DU-1/4 SU-1/4 DU-1/2 SU-1/2 DU-1 SU-1 DU-2 SU-2 DU-3 SU-3 DU-5 SU-5 DU-7.5 SU-7.5 DU-10 SU-10 *Maximum † ± 0.6 (1.6mm) ‡ ± 0.12 (3.2mm) Custom versions available upon ...
Page 55
Industrial Control Transformers Isolation and Buck Boost in a NEMA 3R Compliant Enclosure Boost Mode Auto Boost Mode Auto Buck Mode Auto Custom versions available upon request. www.signaltransformer.com The ICT series is designed with flexibility to support both isolation and/or ...
Page 56
Industrial Control Transformers Isolation and Buck Boost in a NEMA 3R Compliant Enclosure Case A Case B Custom versions available upon request. www.signaltransformer.com Case C ©2008 Signal Transformer — Specification subject to change without notice. 07.08 500 Bayview Avenue, Inwood, ...
Page 57
Three Phase Transformers Custom Designs to Meet Your Requirements Available with UL Recognition Wye-Delta Connection Capabilities From small PC mount 100 VA devices to large 45 KVA designs, we tailor these transformers to your specific needs. Our Three Phase transformers ...
Page 58
High Frequency Custom Transformers Custom Designs To Meet Your Requirements Custom versions available upon request. www.signaltransformer.com • Transformers for switch-mode power supplies • Telecom coupling transformers • Common mode chokes • Current sensing transformers • Surface mount or through hole ...
Page 59
Accessories Mounting Hardware | TransPort™ Connectors • Signal’s accessory products include brackets, screws and TransPort™ connectors to be used in conjunction with a variety of our power transformers. Brackets ø0.156" (4) holes 1.50" 1.65" 1.90" 1.13" 0.77" Material: 0.036" CRS ...
Page 60
Accessories Mounting Hardware | TransPort™ Connectors TransPort™ Connector Part Number Positions TB-1-1/4-6 TB-1-3/8-7 TB-1-1/2-7 TB-1-3/4-8 TB-2-1/8-8 TB-2-1/4-8 TB-2-1/2-8 www.signaltransformer.com TransPort™ Connectors • Provides touch safe terminations and conforms to IEC60529 / IP20 requirements • Designed to support multiple connection schemes ...
Page 61
How to Specify Power Transformer & Filter Parameters The following sections present a practical guide for the selection of power supply transformers, rectification schemes and filter components. A number of basic assumptions have been made to allow focusing on the ...
Page 62
How to Specify Power Transformer & Filter Parameters How to specify power transformer 3. Full-Wave Bridge Uses full secondary winding continuously with no requirement for center-tap. This bridge requires 4 diodes. As can & filter ratings How to specify power ...
Page 63
How to Specify Power Transformer & Filter Parameters VNOM divided by VLOWLINE is the ratio of nominal AC line voltage to the specified low line conditions. A sample calculation appears below for a supply requiring an output ...
Page 64
RMS. Possible Signal parts would be ST-4-36, PC-34-300, PC-40-250. A precautionary calculation remains to be made. How to Specify Power Transformer & Filter Parameters That is, the increase in voltage at the filter capacitor (into the regulator) caused by a ...
Page 65
How to Specify Power Transformer & Filter Parameters Signal Transformer - % Load Regulation of Standard Transformers Family or Series Size or VA Rating 2.5, 5.0, 10VA 14A & 14A-R 20, 30 & (International 2VA-18VA Flathead) 24VA ...
Page 66
How to Specify Power Transformer & Filter Parameters Summary The preceding has been an attempt to provide a simple, practical method of specifying transformers for main stream applications. Certain simplifying assumptions were made so this work-up does not represent a ...
Page 67
How to Specify Power Transformer & Filter Parameters Diode Selection True RMS value of the current flowing into a capacitor Input filter times the DC output current because the current is delivered in short pulses. Assuming ...
Page 68
Signal Transformer 500 Bayview Avenue Inwood, NY 11096-1792 Phone: 516 239 5777 Fax: 516 239 7208 sales@signaltransformer.com techhelp@signaltransformer.com www.signaltransformer.com Catalog ST-6 ...