MSA2805S Interpoint Corp., MSA2805S Datasheet - Page 2

no-image

MSA2805S

Manufacturer Part Number
MSA2805S
Description
Dc/dc Converters
Manufacturer
Interpoint Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MSA2805S
Manufacturer:
TI
Quantity:
12
Part Number:
MSA2805S
Manufacturer:
INTERSIL
Quantity:
770
Part Number:
MSA2805S/883
Manufacturer:
INTERPOINT
Quantity:
3
Part Number:
MSA2805S/883
Manufacturer:
interpoint
Quantity:
16
Part Number:
MSA2805S/883
Manufacturer:
INTERSIL
Quantity:
550
Part Number:
MSA2805S/ES
Manufacturer:
a
Quantity:
39
Part Number:
MSA2805S/ES
Manufacturer:
CY
Quantity:
450
SINGLE OUTPUT MODELS
OUTPUT VOLTAGE
OUTPUT CURRENT
Tc = –55°C TO +125°C
OUTPUT POWER
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
Tc = –55°C TO +125°C
INPUT RIPPLE
EFFICIENCY
LOAD FAULT
SHORT CIRCUIT
STEP LOAD
RESPONSE
STEP LINE
RESPONSE
START-UP
Notes
1. MSA2860S specifications are at 25°Tc only, contact your Interpoint
2. Line regulation for /ES and non /ES 2805S models at 16 to 17 V
MSA SERIES
5 WATT
Input Voltage
Output Power
Lead Soldering Temperature (10 sec per lead)
Storage Temperature Range (Case)
2
PARAMETER
CURRENT
representative for more information on over temperature specs.
°C to 125°C (case) is 5% (max).
• 16 to 40 V
• 5 watts
• 300°C
• –65°C to +135°C
ABSOLUTE MAXIMUM RATINGS
4, 5
4, 5
3, 4
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
POWER DISSIPATION
Tc = –55°C TO +125°C
V
V
V
NO LOAD TO FULL
TRANSIENT 50 ms
50% - 100% - 50%
IN
IN
IN
10 kHz - 10 MHz
10 kHz - 2 MHz
CONTINUOUS
OVERSHOOT
CONDITIONS
16 TO 40 V
40 TO 16 V
16 TO 40 V
40 TO 16 V
= 16 TO 40 VDC
= 16 TO 40 VDC
= 16 TO 40 VDC
TRANSIENT
TRANSIENT
RECOVERY
RECOVERY
RECOVERY
FULL LOAD
INHIBITED
NO LOAD
DELAY
IN
IN
IN
IN
MIN TYP MAX MIN
4.95 5.00
DC/DC C
16
66
0
0
MSA2805S
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
Case Operating Temperature (Tc)
Derating Output Power/Current (Tc)
12.5
125
250
100
100
100
200
1.5
10
10
28
27
25
30
71
50
50
10
3
0
• 16 to 40 VDC continuous
• 50 V for up to 50 msec transient
• –55°C to +125°C full power
• –55°C to +135°C absolute
• Linearly from 100% at 125°C to 0% at 135°C
Inhibit TTL Open Collector
1000
5.05
350
50
100
150
250
250
150
150
250
500
2.0
50
40
50
40
25
25
50
5
5
• Logic low (output disabled)
• Referenced to input common
• Logic high (output enabled)
IN
2
Logic low voltage ≤0.8 V max
Inhibit pin current 4 mA max
and 110
5.15
16
66
0
0
MSA285R2S
ONVERTERS
Open collector
TYP MAX MIN TYP
5.20 5.25 11.88 12.00 12.12 14.85 15.00 15.15 59.1 60.00 60.9
INHIBIT
110
250
100
100
100
200
1.5
1.5
10
10
28
28
25
30
71
50
50
10
3
0
3. Indefinite short circuit protection not guaranteed above 125°C (case).
4. Recovery time is measured from application of the transient to point at which
5. Transition time >10µs.
V
962
335
100
150
250
250
150
150
250
500
2.0
50
50
40
50
40
25
25
50
5
5
OUT
is within 1% of V
16
70
0
0
MSA2812S
235
150
200
100
250
250
1.2
50
10
10
28
29
25
30
76
80
3
1
3
0
MAX MIN
417
200
100
150
375
500
200
250
625
625
120
1.9
50
50
40
50
42
10
10
5
5
OUT
at final value.
16
71
0
0
MSA2815S
Output Voltage Temperature Coefficient
Input to Output Capacitance
Isolation
Audio Rejection
Conversion Frequency
Inhibit Pin Voltage (unit enabled)
TYP MAX
• 100 ppm/°C typical
• 50 pF typical
• 100 megohm minimum at 500 V
• 50 dB typical
• 550 kHz typical (400 kHz 60 V model)
• 9 to 11 V
235
200
200
250
250
1.2
TYPICAL CHARACTERISTICS
50
10
10
28
31
25
30
76
50
50
3
1
3
0
450 kHz min, 600 kHz max
350 kHz min, 450 kHz max 60 V model
333
170
100
150
500
500
125
125
625
625
150
1.8
50
50
40
50
44
10
10
5
5
MIN
70
16
0
0
MSA2860S
TYP MAX
28
72
75
3
300
300
300
1.2
1
20
40
50
30
90
5
mV p-p
mA p-p
UNITS
mV pk
mV pk
mV pk
VDC
VDC
mA
mV
mV
mA
ms
ms
µs
µs
W
%
W
V

Related parts for MSA2805S