MAX16048 Maxim Integrated Products, MAX16048 Datasheet - Page 17

no-image

MAX16048

Manufacturer Part Number
MAX16048
Description
(MAX16046 / MAX16048) 12-Channel/8-Channel EEPROM-Programmable System Managers
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX16048ACB+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX16048ACB+T
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
MAX16048ETN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
www.DataSheet4U.com
Table 2. Input Monitor Ranges and Enables
System Managers with Nonvolatile Fault Registers
REGISTER/
ADDRESS
EEPROM
0Fh
10h
12-Channel/8-Channel EEPROM-Programmable
______________________________________________________________________________________
BIT RANGE
[1:0]
[3:2]
[5:4]
[7:6]
[1:0]
[3:2]
[5:4]
[7:6]
MON1 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON1 is not converted or monitored
MON2 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON2 is not converted or monitored
MON3 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON3 is not converted or monitored
MON4 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON4 is not converted or monitored
MON5 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON5 is not converted or monitored
MON6 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON6 is not converted or monitored
MON7 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON7 is not converted or monitored
MON8 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON8 is not converted or monitored
DESCRIPTION
17

Related parts for MAX16048