LD48-42-YY technipower Systems, LD48-42-YY Datasheet - Page 2

no-image

LD48-42-YY

Manufacturer Part Number
LD48-42-YY
Description
Ld Series 4 Models ? Single Output ? Up To 2000 Watts 2u Redundant Hot Swap Or Embedded System Power Supplies
Manufacturer
technipower Systems
Datasheet
INPUT
90-264 VAC, 47-63 Hz.
POWER FACTOR
0.99 typical.
EMISSIONS
EN 55022/CISPR 22, Class B Conducted.
EN 61000-3-2, Class A Harmonics.
IMMUNITY
EN 61000-4-2, Level 3 Electrostatic Discharge.
EN 61000-4-4, Level 3 Electrical Fast Transients.
EN 61000-4-5, Level 3 Surge.
INPUT SURGE
230VAC - 100 amps max. 115VAC - 50 amps max.
EFFICIENCY
Greater than 80%.
HOLDUP TIME
20 milliseconds from loss of AC power.
OUTPUTS
See model selection table. Outputs are trim
adjustable ±5%.
OUTPUT POLARITY
Output is floating from chassis and can be
referenced to ground as required.
LINE REGULATION
Less than 0.2% for full line change.
LOAD REGULATION
Less than 1% for full load change.
MINIMUM LOAD
None required.
RIPPLE & NOISE
1% pk.-pk., 20 MHz bandwidth.
OPERATING TEMPERATURE
0-70° C. Derate 2.5%/°C above 50° C.
TEMPERATURE COEFFICIENT
0.02%/° C typical.
DYNAMIC RESPONSE
Peak transient less than ±2% for a step load
change from 75% to 50% or 100% max. Output
recovers within 300 microseconds.
SAFETY
Units
No. 60950-1, EN 60950.
ISOLATION
Conforms to safety agency standards.
LD SERIES SPECIFICATIONS
certified
to
UL
60950-1, CSA
22.2
INPUT UNDERVOLTAGE
Protects
operation.
SOFT START
Units have soft start feature to protect critical
components.
OVERVOLTAGE PROTECTION
Standard on all models. Latching action. Recycle
input to re-start.
REVERSE VOLTAGE PROTECTION
Output is are protected up to 100% load ratings.
OVERLOAD & SHORT CIRCUIT
Output is current limited with automatic recovery
when overload is removed.
CURRENT SHARE
Single wire current share.
THERMAL SHUTDOWN
Circuit cuts off supply in case of local over
temperature. Units reset automatically when
temperature returns to normal.
POWER FAIL MONITOR
Standard circuit provides TTL ACFAIL signal
providing 4 millisecond warning before output
drops by 5% after an input failure.
DC GOOD
Standard circuit provides an energized open
collector when output is at least 90% of nominal
value.
HI TEMP
TTL compatible logic signal provides warning
when unit approaches thermal shutdown.
FAN FAIL
TTL compatible logic signal provides warning
when fan speed is inadequate to cool unit.
INHIBIT
TTL compatible system inhibit provided.
PILOT BIAS
+5 VDC @ 0.5 Amps.
ENABLE
Enable pin must be shorted to Common for
proper operation.
REMOTE SENSING
Standard on output.
against
damage
for
undervoltage
SHOCK & VIBRATION
Shock per MIL-STD 810-E
Procedure I. Vibration per MIL-STD 810-E
Method 514.4, Category 1, Procedure I.
MECHANICAL
Chassis dimensions are 3.16” H x 3.48” W
x 12.93" L.
CONNECTIONS
Connections via Positronic connector. Option 08
allows connection to power supply via screw
terminals for output, Euro block for input and
header for signals.
WARRANTY
Deltron’s 2 year Standard Warranty applies.
OPTIONS:
OPTIONS:
REDUNDANCY (Code 01)
Redundant operation with Or-ing diodes coupled
with standard single wire current sharing for use
as a hot pluggable N+1 redundant system.
FIELD TERMINATIONS (Code 08)
Provides
pluggable interface enabling customer to connect
to power supply via field connections. Output
terminals are 10-32 screws. Input terminals are
via Euro block. A 14 pin header handles signals
and functions. Mating ribbon cable connectors
provided. Option includes front panel LED
indicators for AC, DC Good and Hi Temp.
IEEE 802.3at COMPLIANCE (Code 16)
Option to provide 2250VDC output to ground
isolation and 48-51VDC adjustment. Applicable
to 48V models.
I
Consult factory for specifications.
RACKING SYSTEM
The RA120A 2U high, 19" wide racking system
measures 3.50" H x 14.0" D. The RA120B rack
also measures 19" W x 3.5" H, but measures
11.3” deep. Each rack accommodates up to four
LD Series power supplies providing up to 8000
watts.
OPTIONS: